Malik KAYA

Dr. Malik KAYA


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in Physica Scripta
Verified
Journal Article
Open access
MKMalik KAYA
Malik KAYA
OEOkan Esenturk
Okan Esenturk
CACelal Asici
Celal Asici
USumut sarac
umut sarac
GDGökhan Dındış
Gökhan Dındış
MBMevlana Celalettin BAYKUL
Mevlana Celalettin BAYKUL
A sensor region in a single-mode optical fiber loop was created and utilized in order to study the coating effect on sensor durability and system sensitivity by the Fiber Loop Ringdown Spectroscopy (FLRDS) technique. The sensor system was simply designed without any additional optical components. The bending loss theory in the single-mode fiber (SMF) was taken into account in data calculation. After stretching was performed on 10.0 cm long coated and noncoated sensorheads from the mid-points, the strain detection limits were determined as 5.3345 με and 6.7497 με with bare and coated sensorheads, respectively. The purpose of this study is to analyze the effect of N,N-Diethyl-p-phenylenediamine (NDPD) coating of the sensorhead on the sensor durability and sensitivity. The baseline stability of the system was obtained as 1.18% by considering a hundred consecutive data. Regarding to obtained results, the difference between calculated total optical losses of FLRDS systems with noncoated and NDPD coated sensorheads shows that coating sensorhead enhanced the sensor durability and the system sensitivity. An FLRDS system with high sensitivity, simple design and easy setup offers real-time measurement with continuous monitoring and provides advantages on durability by modification the sensorhead such as NDPD coating. Due to its attractive features such as low cost, simplicity, easy setup, high sensitivity, increased durability and continuous monitoring, an FLRDS system has a wide range of application areas in structural health monitoring, transportation, early detection, biomedical, chemical trace elements, rail and asphalt applications for continuous monitoring in a real-time merit.

16 August 2024 in Physica Scripta
Verified
Journal Article
Open access
PDF file
MKMalik KAYA
Malik KAYA
A single mode optical fiber loop was employed as a temperature sensor to observe changes in optical loss regarding to ringdown time (RDT) by high sensitive the fiber loop ringdown spectroscopy (FLRDS) technique which has real-time and fast response measurement capability due to allowing trapped light pulse multiple interactions with the measurands. Two different fiber loops of 45 ± 5 m and 120 ± 5 m lengths were embedded one by one into a copper, circular and closed housing. Continuous monitoring of RDTs was carried out by changing the temperature in the range of 25–200 °C with the steps of 25 °C for the first time by using bare fiber without any modification as a temperature sensor. The FLRDS system for temperature sensing has simple design without extra components such as an optical time domain reflectometer (OTDR), long-period fiber grating (LPFG) or fiber Bragg grating (FBG) as sensorhead. The FLRDS system was diligently optimized to achieve the lowest baseline as %0.49. Since the RDT of the FLRDS system was changed due to the thermal expansion of the fiber, continuous monitoring of the temperature was the first time recorded by utilizing this kind of FLRDS temperature sensor. These kind of FLRDS temperature sensors have high potential to be employed in mining, nuclear facilities, railways, underwater structures, biomedical, medicine, structural health monitoring, transportation and communication applications with simple system setup, lower cost, higher sensitivity, portability, real-time and continuous monitoring for early detection.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
MKMalik KAYA
Malik KAYA
CWC. Wang
C. Wang
Detection of trace elements in DI water and comparison of several types of water respons such as DI water, tap water, and ocean water were studied by using EF-FLRD chemical sensors. Solutions of Mg, Fe, P, and Cd elements with a concentration of 1000 µg/ml (1 mg/ml) which corresponds to 1000 ppm by weight were tested. DI water, tap water, and real ocean water were utilized as medium to observe refractive index difference of solutions. The EF sensing technique which is based on the EF scattering effect was employed for the detection of trace chemicals and recording of solution responses. Due to the refractive index differences between solutions, optical loss of the sensor was different when the sensor head was immersed into solutions of approximately 10 ml each. The differences of the refractive indices are presented by recording ringdown times when the sensor head was immersed into the solutions. Fast response (∼1s), high sensitive, and reproducible EF-FLRD chemical sensors were fabricated and tested in laboratory conditions. High sensitivity of the sensors due to being capability of detecting smaller differences between measurands without any additional components or treatment makes the EF-FLRD sensors more attractive. Enhanced sensitivity of the EF-FLRD chemical sensors as a result of the multi-pass nature of the FLRD technique has potential application in detecting of trace elements in monitoring of water quality.

25 September 2020 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Closed access
MKMalik KAYA
Malik KAYA

25 September 2020 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Closed access
MKMalik KAYA
Malik KAYA
OEOkan Esentürk
Okan Esentürk

26 April 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
MKMalik KAYA
Malik KAYA
SÖSemih ÖZ
Semih ÖZ
OEOkan Esenturk
Okan Esenturk
A novel fiber optic biosensor was purposed for a new approach to monitor amyloid beta protein fragment 1–42 (Aβ42) for Alzheimer’s Disease (AD) early detection. The sensor was fabricated by etching a part of fiber from single mode fiber loop in pure hydrofluoric acid solution and utilized as a Local Optical Refractometer (LOR) to monitor the change Aβ42 concentration in Artificial Cerebrospinal Fluid (ACSF). The Fiber Loop Ringdown Spectroscopy (FLRDS) technique is an ultra-sensitive measurement technique with low-cost, high sensitivity, real-time measurement, continuous measurement and portability features that was utilized with a fiber optic sensor for the first time for the detection of a biological signature in an ACSF environment. Here, the measurement is based on the total optical loss detection when specially fabricated sensor heads were immersed into ACSF solutions with and without different concentrations of Aβ42 biomarkers since the bulk refractive index change was performed. Baseline stability and the reference ring down times of the sensor head were measured in the air as 0.87% and 441.6 μs ± 3.9 μs, respectively. Afterward, the total optical loss of the system was measured when the sensor head was immersed in deionized water, ACSF solution, and ACSF solutions with Aβ42 in different concentrations. The lowest Aβ42 concentration of 2 ppm was detected by LOR. Results showed that LOR fabricated by single-mode fibers for FLRDS system design are promising candidates to be utilized as fiber optic biosensors after sensor head modification and have a high potential for early detection applications of not only AD but possibly also several fatal diseases such as diabetes and cancer.