Nobuo Sato

Dr. Nobuo Sato

Tokyo Women's Medical University, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Physiology & Behavior
Verified
Journal Article
Closed access
NSNobuo Sato
Nobuo Sato
SMShuri Marui
Shuri Marui
MOMakoto Ozaki
Makoto Ozaki
KNKei Nagashima
Kei Nagashima

15 September 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
KMKentaro Matsui
Kentaro Matsui
NSNobuo Sato
Nobuo Sato
MIMasafumi Idei
Masafumi Idei
真荒真子 荒木田
真子 荒木田
YSYusuke Seino
Yusuke Seino
TNTAKESHI NOMURA
TAKESHI NOMURA
The relationship between polysomnography-based objective sleep and delirium in the intensive care unit (ICU) is inconsistent across studies, suggesting limitations in manually determining the sleep stage of critically ill patients. We objectively measured 24-h sleep using a single-channel electroencephalogram (SleepScope [SS]) and an under-mattress sleep monitor (Nemuri SCAN [NSCAN]), both of which have independent algorithms that automatically determine sleep and wakefulness. Eighteen patients (median age, 68 years) admitted to the ICU after valvular surgery or coronary artery bypass grafting were included, and their sleep time was measured one day after extubation. The median total sleep times (TSTs) measured by SS (TST-SS) and NSCAN were 548 (48–1050) and 1024 (462–1257) min, respectively. Two patients with delirium during the 24-h sleep measurement had very short TST-SS of 48 and 125 min, and the percentage of daytime sleep accounted for >80% in both SS and NSCAN. This preliminary case series showed marked sleep deprivation and increased rates of daytime sleeping in ICU patients with delirium. Although data accuracy from under-mattress sleep monitors is contentious, automated algorithmic sleep/wakefulness determination using a single-channel electroencephalogram may be useful in detecting delirium in ICU patients and could even be superior to polysomnography.

31 August 2022 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
YSYusuke Seino
Yusuke Seino
NSNobuo Sato
Nobuo Sato
MIMasafumi Idei
Masafumi Idei
TNTakeshi Nomura
Takeshi Nomura
Background: Although the various advantages of clinical information systems in intensive care units (ICUs), such as intensive care information systems (ICISs), have been reported, their role in preventing medical errors remains unclear. Objective: This study aimed to investigate the changes in the incidence and type of errors in the ICU before and after ICIS implementation in a setting where a hospital electronic medical record system is already in use. Methods: An ICIS was introduced to the general ICU of a university hospital. After a step-by-step implementation lasting 3 months, the ICIS was used for all patients starting from April 2019. We performed a retrospective analysis of the errors in the ICU during the 6-month period before and after ICIS implementation by using data from an incident reporting system, and the number, incidence rate, type, and patient outcome level of errors were determined. Results: From April 2018 to September 2018, 755 patients were admitted to the ICU, and 719 patients were admitted from April 2019 to September 2019. The number of errors was 153 in the 2018 study period and 71 in the 2019 study period. The error incidence rates in 2018 and 2019 were 54.1 (95% CI 45.9-63.4) and 27.3 (95% CI 21.3-34.4) events per 1000 patient-days, respectively (P<.001). During both periods, there were no significant changes in the composition of the types of errors (P=.16), and the most common type of error was medication error. Conclusions: ICIS implementation was temporally associated with a 50% reduction in the number and incidence rate of errors in the ICU. Although the most common type of error was medication error in both study periods, ICIS implementation significantly reduced the number and incidence rate of medication errors. Trial Registration: University Hospital Medical Information Network Clinical Trials Registry UMIN000041471; https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000047345

21 November 2016 in JA Clinical Reports
Verified
Journal Article
Open access
PDF file
NSNobuo Sato
Nobuo Sato
HMHaruhiko Machida
Haruhiko Machida
MKMitsuharu Kodaka
Mitsuharu Kodaka
KNKeiko Nishiyama
Keiko Nishiyama
MKMakiko Komori
Makiko Komori
Posterior reversible encephalopathy syndrome is characterized by reversible neurological symptoms with leukoencephalopathy detectable by computed tomography (CT) and magnetic resonance (MR) imaging. We here present a patient with no history of hypertension who, after being transferred back to the ward after undergoing total hysterectomy under general anesthesia, had several seizures and lost consciousness. Posterior reversible encephalopathy syndrome was suspected on the basis of brain CT images and clinical findings. She was treated with respiratory support, sedative drugs, and anticonvulsants, and MR imaging confirmed a diagnosis of posterior reversible encephalopathy syndrome. She regained consciousness and responsiveness the following day. Clinically, posterior reversible encephalopathy syndrome resembles cerebral infarction or intracranial hemorrhage; MR imaging is useful for differentiating it from these conditions. Including this condition in the differential diagnosis and instituting appropriate treatment is important in minimizing the risk of development of irreversible neurological damage during the perioperative period.

1 July 2020 in Indagationes Mathematicae
Verified
Journal Article
Closed access
MHMinoru Hirose
Minoru Hirose
HMHideki Murahara
Hideki Murahara
TOTomokazu Onozuka
Tomokazu Onozuka
NSNobuo Sato
Nobuo Sato

12 November 2018 in The Ultrasound Journal
Verified
Journal Article
Open access
PDF file
YSYusuke Seino
Yusuke Seino
NSNobuo Sato
Nobuo Sato
KFKimiya Fukui
Kimiya Fukui
JIJunya Ishikawa
Junya Ishikawa
MNMasashi Nakagawa
Masashi Nakagawa
TNTakeshi Nomura
Takeshi Nomura
Systolic anterior motion (SAM) after mitral valve repair (MVR) can adversely affect hemodynamics due to exacerbation of left ventricular outflow tract obstruction and mitral regurgitation. Intraoperative transient SAM after MVR can usually be managed with hemodynamic maneuvers under continuous monitoring by transesophageal echocardiography (TEE). However, during postoperative intensive care management, transient SAM is seldom diagnosed and the start of treatment may be delayed. We present a case of transient SAM after MVR with abrupt deterioration due to junctional rhythm in the intensive care unit (ICU). TEE revealed that conversion from normal sinus rhythm into junctional rhythm induced the exacerbation of SAM. TEE was useful for identifying the etiology of unstable hemodynamics after cardiac surgery in the ICU, similar to its use in the operating room.