Jasmin Sandra Barth

Dr. Jasmin Sandra Barth

Department of Plastic and Hand Surgery, Friedrich-AlexanderUniversity Erlangen-Nürnberg (FAU), Erlangen, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EPElias Polykandriotis
Elias Polykandriotis
JDJonas Daenicke
Jonas Daenicke
ABAnil Bolat
Anil Bolat
JBJasmin Sandra Barth
Jasmin Sandra Barth
DSDirk Schubert
Dirk Schubert
Raymund Engelbert HorchRaymund Engelbert Horch
Raymund Engelbert Horch
Wound closure is a key element of any procedure, especially aesthetic and reconstructive plastic surgery. Therefore, over the last decades, several devices have been developed in order to assist surgeons in achieving better results while saving valuable time. In this work, we give a concise review of the literature and present a biomechanical study of different suturing materials under mechanical load mimicking handling in the operating theatre. Nine different suture products, all of the same USP size (4-0), were subjected to a standardized crushing load by means of a needle holder. All materials were subjected to 0, 1, 3 and 5 crushing load cycles, respectively. The linear tensile strength was measured by means of a universal testing device. Attenuation of tensile strength was evaluated between materials and between crush cycles. In the pooled analysis, the linear tensile strength of the suture materials deteriorated significantly with every cycle (p < 0.0001). The suture materials displayed different initial tensile strengths (in descending order: polyglecaprone, polyglactin, polydioxanone, polyamid, polypropylene). In comparison, materials performed variably in terms of resistance to crush loading. The findings were statistically significant. The reconstructive surgeon has to be flexible and tailor wound closure techniques and materials to the individual patient, procedure and tissue demands; therefore, profound knowledge of the physical properties of the suture strands used is of paramount importance. The crushing load on suture materials during surgery can be detrimental for initial and long-term wound repair strength. As well as the standard wound closure methods (sutures, staples and adhesive strips), there are promising novel devices.

1 September 2019 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
ILI. Ludolph
I. Ludolph
JBJasmin Sandra Barth
Jasmin Sandra Barth
AKA. Kengelbach-Weigand
A. Kengelbach-Weigand
CFC. Fiessler
C. Fiessler
RHR.E. Horch
R.E. Horch
MSM. Schmitz
M. Schmitz

3 February 2020 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Open access
PDF file
JTJulia Tolksdorf
Julia Tolksdorf
RHRaymund E. Horch
Raymund E. Horch
JBJasmin Sandra Barth
Jasmin Sandra Barth
RSRafael Schmid
Rafael Schmid
AKAnnika Kengelbach-Weigand
Annika Kengelbach-Weigand
ILIngo Ludolph
Ingo Ludolph
Capsular contracture remains a challenge in plastic surgery and represents one of the most common postoperative complications following alloplastic breast reconstruction. The impact of the surface structure of silicone implants on the foreign body reaction and the behaviour of connective tissue-producing cells has already been discussed. The aim of this study was to investigate different pore sizes of silicone surfaces and their influence on human fibroblasts in an in vitro model. Four different textures (no, fine, medium and coarse texture) produced with the salt-loss technique, have been assessed in an in vitro model. Human fibroblasts were seeded onto silicone sheets and evaluated after 1, 4 and 7 days microscopically, with viability assay and gene expression analysis. Comparing the growth behaviour and adhesion of the fibroblasts on the four different textures, a dense cell layer, good adhesion and bridge-building ability of the cells could be observed for the fine and medium texture. Cell number and viability of the cells were increasing during the time course of experiments on every texture.TGFß1was lowest expressed on the fine and medium texture indicating a trend for decreased fibrotic activity. For silicone surfaces produced with the salt-loss technique, we were able to show an antifibrotic effect of smaller sized pores. These findings underline the hypothesis of a key role of the implant surface and the pore size and pore structure in preventing capsular contracture.

13 December 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
JBJasmin Sandra Barth
Jasmin Sandra Barth
Raymund Engelbert HorchRaymund Engelbert Horch
Raymund Engelbert Horch
AGAlexander Geierlehner
Alexander Geierlehner
WMWibke Müller-Seubert
Wibke Müller-Seubert
Aijia CaiAijia Cai
Aijia Cai
ILIngo Ludolph
Ingo Ludolph
Peri-prosthetic breast infections pose a risk of severe complications after breast implant surgery. The need to remove the breast implant, control the infection and perform additional surgical procedures are the consequences. Reimplantation of an alloplastic implant is only appropriate after an infection-free interval. In this retrospective cohort study, we investigated the effectiveness of negative pressure wound treatment with instillation and dwell time (NPWTi-d) on peri-prosthetic breast infections in combination with implant removal and antibiotic therapy. Twelve patients treated with NPWTi-d due to breast implant infection were included in the study. The bacterial burden was analyzed using wound swabs before and after NPWTi-d. Additionally, laboratory values were determined before NPWTi-d and immediately before wound closure. A total of 13 peri-prosthetic breast infections in 12 patients were treated using implant removal and NPWTi-d. In 76.9% (n = 10) of the cases, the patients had undergone alloplastic breast reconstruction following cancer-related mastectomy, whereas 23.1% (n = 3) of the patients had undergone breast augmentation for cosmetic reasons. The bacterial burden in the breast pocket decreased statistically significant after implant removal and NPWTi-d. No shift from Gram-positive to Gram-negative bacteria was observed. Inflammatory markers rapidly decreased following treatment. NPWTi-d had a positive impact on the healing process after peri-prosthetic breast infections, leading to a decrease in bacterial burden within the wounds and contributing to uneventful healing. Therefore, secondary reimplantation of breast prostheses might be positively influenced when compared to conventional implant removal and simple secondary closure. Further studies are required to conclusively establish the beneficial long-term effects of using NPWTi-d for the treatment of peri-prosthetic breast infections.

19 April 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
FRFlorian Ruppe
Florian Ruppe
MNMiriam Niederkorn
Miriam Niederkorn
EPEktor Polykandriotis
Ektor Polykandriotis
LBLars Bräuer
Lars Bräuer
RHRaymund E. Horch
Raymund E. Horch
JBJasmin Sandra Barth
Jasmin Sandra Barth
Background: In this study, we evaluate the value of novel suture material based on monofilamentous-extruded polyfluoroethylene (PTFE) compared to polypropylene (PPL) and Fiberwire (FW). Materials and methods: 60 flexor tendons were harvested from fresh cadaveric upper extremities. 4–0 sutures strands were used in the PPL, FW and PTFE group. Knotting properties and mechanical characteristics of the suture materials were evaluated. A 4-strand locked cruciate (Adelaide) or a 6-strand (M-Tang) suture technique was applied as core sutures for a tendon repair. Two-way ANOVA tests were performed with the Bonferroni correction. Results: Stable knotting was achieved with 5 throws with the PPL material, 7 throws for FW and 9 throws for PTFE. In the PPL group, linear tensile strength was 45.92 ± 12.53 N, in the FW group 80.11 ± 18.34 N and in the PTFE group 76.16 ± 29.10 N. FW and PTFE are significantly stronger than PPL but show no significant difference among each other. Similar results were obtained in the subgroup comparisons for different repair techniques. The Adelaide and the M-Tang knotting technique showed no significant difference. Conclusion: Fiberwire showed superior handling and knotting properties in comparison to PTFE. However, PTFE allows easier approximation of the stumps. In both, M-Tang and Adelaide repairs, PTFE was equal to FW in terms of repair strength. Both PTFE and FW provide for a robust tendon repair so that early active motion regimens for rehabilitation can be applied.

24 July 2023 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
JBJasmin Sandra Barth
Jasmin Sandra Barth
ACAijia Cai
Aijia Cai
IPIsabel Pingel
Isabel Pingel
RHRaymund E. Horch
Raymund E. Horch
JBJustus P. Beier
Justus P. Beier
AAAndreas Arkudas
Andreas Arkudas
Background: Carpal tunnel syndrome, A1 annular pulley stenosis and Dupuytren’s contracture are among the most common conditions of the hand. In this study, we investigated the impact of surgical procedure on hand grip strength and high-resolution spatial load distribution in individuals suffering from those diseases over a follow-up period of one year. Materials and methods: In this prospective study, data of 9 patients with carpal tunnel syndrome, 12 patients with A1 annular pulley stenosis and 7 patients with Dupuytren’s contracture were evaluated. Only patients with unilateral disease were included providing the contralateral hand as an intra-individual control. Grip strength was measured with cylindrical instruments in two different sizes with respect to the hand size of the patients. Maximum and average values of grip strength as well as spatial load distribution in each finger, thenar, hypothenar and palm were analyzed. Data of the affected patients were collected preoperatively and 6 weeks, 6 months and 1 year postoperatively. Grip strength and spatial load distribution were compared preoperatively to postoperatively. In addition, DASH score, Levine score, 2-point discrimination and degree of flexion contracture were assessed. Results: The patients with A1 annular pulley stenosis showed a significant increase in grip strength 6 months and one year postoperatively. Patients with carpal tunnel syndrome and Dupuytren’s contracture showed no significant difference in grip strength over the course of time. An increase in the percentual grip strength of the thenar in patients with carpal tunnel disease and within the affected finger in A1 annular pulley stenosis was observed over the course of time. The DASH score was significantly lower in all patient cohorts one year postoperatively. Conclusion: Surgical procedure in carpal tunnel syndrome, A1 annular ligament stenosis and Dupuytren’s contracture improves the functionality of the hand in everyday life. Some areas of the hand seem to compensate other weaker areas in grip strength.