Kathrine Curtin

Ms. Kathrine Curtin

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
KCKathrine Curtin
Kathrine Curtin
BFBethany Joy Fike
Bethany Joy Fike
BBBrandi Binkley
Brandi Binkley
TGToktam Godary
Toktam Godary
PLPeng Li
Peng Li
Digital biosensing assays demonstrate remarkable advantages over conventional biosensing systems because of their ability to achieve single-molecule detection and absolute quantification. Unlike traditional low-abundance biomarking screening, digital-based biosensing systems reduce sample volumes significantly to the fL-nL level, which vastly reduces overall reagent consumption, improves reaction time and throughput, and enables high sensitivity and single target detection. This review presents the current technology for compartmentalizing reactions and their applications in detecting proteins and nucleic acids. We also analyze existing challenges and future opportunities associated with digital biosensing and research opportunities for developing integrated digital biosensing systems.

1 May 2017 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
PZPeng Zheng
Peng Zheng
XSXiaofei Shi
Xiaofei Shi
KCKathrine Curtin
Kathrine Curtin
FYFeng Yang
Feng Yang
NWNianqiang Wu
Nianqiang Wu

7 September 2023 in Analytica Chimica Acta
Verified
Journal Article
Closed access
JWJing Wang
Jing Wang
KCKathrine Curtin
Kathrine Curtin
SVStephen J. Valentine
Stephen J. Valentine
PLPeng Li
Peng Li

30 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
BFBethany Joy Fike
Bethany Joy Fike
KCKathrine Curtin
Kathrine Curtin
PLPeng Li
Peng Li
Nucleic acid tests are key tools for the detection and diagnosis of many diseases. In many cases, the amplification of the nucleic acids is required to reach a detectable level. To make nucleic acid amplification tests more accessible to a point-of-care (POC) setting, isothermal amplification can be performed with a simple heating source. Although these tests are being performed in bulk reactions, the quantification is not as accurate as it would be with digital amplification. Here, we introduce the use of the vibrating sharp-tip capillary for a simple and portable system for tunable on-demand droplet generation. Because of the large range of droplet sizes possible and the tunability of the vibrating sharp-tip capillary, a high dynamic range (~2 to 6000 copies/µL) digital droplet loop-mediated isothermal amplification (ddLAMP) system has been developed. It was also noted that by changing the type of capillary on the vibrating sharp-tip capillary, the same mechanism can be used for simple and portable DNA fragmentation. With the incorporation of these elements, the present work paves the way for achieving digital nucleic acid tests in a POC setting with limited resources.

1 September 2017 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
KCKathrine Curtin
Kathrine Curtin
SKSujan Kasani
Sujan Kasani
PZPeng Zheng
Peng Zheng
NWNianqiang Wu
Nianqiang Wu
Biosensors are novel devices for offering fast, point of care results in healthcare fields. Nanostructures can improve the performance of biosensors. For example, plasmonic gold nanohole arrays have been demonstrated to amplify the surface-enhanced Raman scattering (SERS) signal in biosensors because of their unique optical properties and highly tunable localized surface plasmon resonance (LSPR). However, it remains a challenge to fabricate nanostructures such as nanohole arrays. Herein a gold nanohole array-silica spacer-gold nanodisk array has been fabricated based on nanosphere lithography. The SERS effect is considerably improved due to the plasmonic coupling between the gold nanohole array and the nanodisk array separated by a small silica gap (~10 nm). Ultraviolet-visible spectroscopy, Raman spectroscopy, and finite-difference time domain simulations have been used to characterize the performance. The plasmonic nanostructure obtained can be potentially integrated into microfluidic devices for healthcare and environmental monitoring.

23 July 2018 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
KCKathrine Curtin
Kathrine Curtin
NWNick Wu
Nick Wu
Biosensors are novel devices for offering fast, point of care results in healthcare and environmental fields compared to expensive, time-consuming laboratory instruments and techniques. Nanostructures have been shown improve the performance of biosensors. Nianqiang Wu’s research group explores biosensor signal transduction methods and sensor designs with nanostructure integration for detection of cancer biomarkers, heavy metals, and protein biomarkers. For example, plasmonic gold nanostructures, such as nanoarrays, nanostars and nanorods, have been demonstrated to amplify the surface-enhanced Raman scattering (SERS) signal in biosensors because of their unique optical properties and highly tunable localized surface plasmon resonance (LSPR). Fluorescence biosensors for resonant energy transfer have been explored using quantum dots, graphene oxide, and plasmonic nanostructures. The fundamental working principles and performance optimizations are extensively characterized and investigated in this group. Both fluorescence and SERS have been used in developing paper-based lateral flow and microfluidic, lab-on- chip biosensors for cancer biomarkers, heavy metals, and traumatic brain injury protein biomarkers.