XU ZHANG

Dr. XU ZHANG

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
XZXU ZHANG
XU ZHANG
LWLingling Wang
Lingling Wang
NFNa Feng
Na Feng
TNTu Ni
Tu Ni
WTWei Tang
Wei Tang
Aim: We aimed to evaluate the ability of contrast-enhanced ultrasonography (CEUS) to perform differential diagnosis of cervical tuberculous lymphadenitis and lymph node metastasis from papillary thyroid cancer (PTC).Methods: We analyzed 102 enlarged cervical lymph nodes as diagnosed by conventional ultrasound (US) and CEUS. The US and CEUS enhancement pattern and the time intensity curve (TIC) of the metastatic lymph nodes or tuberculous lymph nodes were compared following standard pathological protocols. The TIC included peak time (TTP), peak intensity (PI), and area under the gamma curve (AUC).Results: Pathological results demonstrated that 48 out of the 102 enlarged lymph nodes were lymph node metastasis from PTC, while 54 were tuberculous lymphadenitis. There was statistically significant differences in hyperechoic islands, pulse-like enhancement, and asynchronous enhancement between tuberculous lymphadenitis and lymph node metastasis (P < 0.05), but their diagnostic sensitivity and specificity were unsatisfactory. In addition, our data did not show statistically significant difference in enhancement direction, enlarged range on CEUS, and perfusion defect (P > 0.05). Similarly, quantitative parameters such as PI, TTP, and AUC did not yield significant differences between the groups.Conclusion: Taken together, the present results demonstrate that CEUS can provide valuable information on lymph node blood flow, which can be used to identify tuberculous lymphadenitis and lymph node metastasis of PTC.

27 June 2022 in Frontiers in Endocrinology
Verified
Journal Article
Open access
XZXU ZHANG
XU ZHANG
TNTu Ni
Tu Ni
WZWenzhi Zhang
Wenzhi Zhang
Aim: The study aimed to systematically evaluate the safety and efficacy of ultrasonography-guided percutaneous thermal ablation in the treatment of cervical lymph node metastasis (LNM) of recurrent papillary thyroid carcinoma (PTC).Methods: PubMed, PubMed Central (PMC), Embase, and Cochrane were examined. The inclusion and exclusion criteria were determined and the relevant data were extracted from the library and other databases for LNM thermal ablation of recurrent PTC. The data were analyzed using Stata15.1, Revman5.3 software, and the standard errors of 95% confidence intervals were estimated using fixed or random effects models. Volume reduction rate (VRR), Serum thyroglobulin (Tg) level before and after thermal ablation, the total complications and major complications incidence were analyzed.Results: A total of 18 literature articles were included, namely, 10 radiofrequency ablation (RFA), 4 laser ablation (LA), and 4 microwave ablation (MWA). A total of 321 patients had 498 LNM. LNM volume changes before and at the last follow-up of thermal ablation (SMD = 1.04, I2 = 8%, 95% CI 0.86–1.21, P <0.0001). The postoperative lymph node VRR was 88.4% (95% CI 77.8–97.3%, I2 = 34%, P = 0.14). Tg measurements before and after thermal ablation (SMD = 1.15, 95% CI 0.69–1.60, I2 = 84%, P <0.0001). The incidence of total complications was 5.0% (95% CI 3.0–7.0%, I2 = 0.0%, P = 0.915), and the incidence of major complications was 4.0% (95% CI 2.0–6.0%, I2 = 0.0%, P = 0.888). A total of 131 LNM were located in the central region, and the major complication rate was 12.0% (95% CI 6.0–18.0%, I2 = 0.0%, P = 0.653).Conclusion: Ultrasonography-guided thermal ablation is safe and effective in the treatment of LNM of recurrent PTC. The ablation strategy of central LNM needs to be further explored and improved. It can be used as an alternative to surgery for patients with high surgical risk or who refuse resurgery.Systematic Review Registration: 10.37766/inplasy2022.6.0004, identifier INPLASY202260004.

18 June 2024 in Oncology Letters
Verified
Journal Article
Open access
PDF file
QAQinqin Ai
Qinqin Ai
DLDelin Liu
Delin Liu
FLFei Liang
Fei Liang
ZKZixiang Kong
Zixiang Kong
YPYANGHONG PAN
YANGHONG PAN
XZXU ZHANG
XU ZHANG
Liver cancer near the deep diaphragm can be difficult to visualize due to the effects of lung gas, which presents a challenge for microwave ablation (MWA). The present study aimed to investigate the feasibility and efficacy of artificial ascites‑assisted MWA for treating liver cancer near the deep diaphragm, as well as the significance of perioperative nursing. A retrospective analysis was conducted on patients who underwent artificial ascites‑assisted MWA for liver cancer located near the deep diaphragm between January 2016 and December 2022. Normal saline was utilized as artificial ascites to safeguard the deep diaphragm during MWA. The study recorded the procedural success rate, incidence of major complications, technical efficacy of ablation and local tumor progression (LTP). A total of 62 lesions in 54 patients were included, with 44 men and 10 women, and a mean (± SD) age of 55.64±10.33 years. The ultrasound image quality scores for liver cancer before and after ascites were 3.57±0.79 and 4.89±0.33, respectively, showing a statistically significant difference between the two groups (t=16.324; P<0.05). No diaphragm injury, skin burns at the puncture site or abdominal hemorrhage occurred during the procedure. A single patient developed right‑sided pleural effusion, which did not require drainage. The complete ablation rate was 94.4% (51/54) at 1 month post‑ablation, with 3 patients experiencing recurrence and receiving additional MWA treatment. The median follow‑up time for the patients in this study was 21 months (range, 12‑45 months), with a LTP rate of 5.6% (3/54). In conclusion, MWA assisted by artificial ascites is a safe and effective treatment for liver cancer near the deep diaphragm. Furthermore, perioperative treatment and rehabilitation of the patients with high‑quality nursing is beneficial.

11 October 2024 in IDCases
Verified
Journal Article
Open access
XZXU ZHANG
XU ZHANG
DSDongming Su
Dongming Su
TNTu Ni
Tu Ni
YHYi Hu
Yi Hu
Testicular tuberculosis is a rare form of genital tuberculosis. Ultrasound is a crucial tool for evaluating male genital disorders. Contrast-enhanced ultrasonography (CEUS), which provides real-time monitoring of microvascular hemodynamics, provides rich information about microcirculation, helping distinguish testicular tuberculosis from other testicular conditions such as tumors and inflammation. This study reports on a rare case of testicular tuberculosis diagnosed through CEUS. A 31-year-old male patient presented with two months of persistent right scrotal pain and swelling. Conventional scrotal ultrasound showed an enlarged right testicle with heterogeneous echogenicity and abundant color Doppler blood flow signals. CEUS demonstrated rapid contrast agent filling in the right testicle, followed by the appearance of several irregular regions, indicating perfusion deficits in these areas. Histopathological confirmation through ultrasound-guided biopsy revealed granulomatous inflammation with caseous necrosis, which is consistent with the diagnosis of testicular tuberculosis. As a real-time monitoring technique for microvascular hemodynamics, CEUS provides valuable microcirculatory information that enhances diagnostic accuracy and enables the formulation of appropriate treatment plans for testicular tuberculosis versus other testicular pathologies.

20 July 2023 in European Journal of Radiology
Verified
Journal Article
Open access
WTWei Tang
Wei Tang
YZYing Zhang
Ying Zhang
XYXiu-Lei Yu
Xiu-Lei Yu
WZWen-Zhi Zhang
Wen-Zhi Zhang
PCPei-Jun Chen
Pei-Jun Chen
GYGaoyi Yang
Gaoyi Yang
To investigate the clinical value of the radiomics model of grayscale ultrasound (GUS) and contrast-enhanced ultrasound (CEUS) to diagnosis subpleural pulmonary tuberculosis and nonpulmonary tuberculosis based on GUS and CEUS images. This study included 221 patients with 228 lesions diagnosed using the composite reference standard. The patients were randomly divided into training (n = 183) and test (n = 45) cohorts in an 8:2 ratio. The regions of interest of the GUS and CEUS images were manually segmented to extract the radiomic features. The GUS, CEUS and GUS+CEUS radiomics models were constructed via the multistep selection of highly correlated features. Receiver operating characteristic curves of the different models were plotted, and the area under the curve (AUC), accuracy, sensitivity, specificity, positive predictive value and negative predictive value (NPV) of the different models were compared. Following Least Absolute Shrinkage and Selection Operator dimension reduction we selected 4, 9, and 11 features to construct the GUS, CEUS, and GUS+CEUS radiomics models, respectively. The AUC values of the three groups in the test cohort were 0.689, 0.748 and 0.779, respectively, and they did not differ significantly. In the test cohort, the GUS+CEUS radiomics model exhibited the highest AUC (0.779), accuracy (75.56%), and NPV (68.7%) of the three models. The GUS+CEUS radiomics model possesses good clinical value in diagnosing pulmonary tuberculosis.

24 January 2024 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Closed access
PDF file
YPYanghong Pan
Yanghong Pan
DLDelin Liu
Delin Liu
FLFei Liang
Fei Liang
ZKZixiang Kong
Zixiang Kong
XZXU ZHANG
XU ZHANG
QAQinqin Ai
Qinqin Ai
BACKGROUND: No studies have been retrieved comparing perfluorobutane with sulfur hexafluoride for microwave ablation (MWA) in small hepatocellular carcinoma(sHCC). OBJECTIVE: To retrospective investigate the value of perfluorobutane ultrasonography contrast agent in ultrasonography (US)-guided MWA of sHCC. METHODS: We conducted a retrospective clinical controlled study about US-guided percutaneous MWA in patients with sHCC, and in patients undergoing intra-operative treatment with perfluorobutane or sulfur hexafluoride. In both groups, a contrast agent was injected to clear the tumor and then a needle was inserted. A 5-point needle prick difficulty score was developed to compare needle prick difficulty in the two groups of cases. RESULTS: A total of 67 patients were included: 25 patients in group perfluorobutane, aged 41–82 (60.64±9.46), tumor size 1.1–2.8 (1.78±0.45) cm. 42 patients in group sulfur hexafluoride, aged 38–78 (62.26±9.27), with tumor size of 1.1–3.0 (1.89±0.49) cm. There was no significant difference in age or tumor size in both groups ( P > 0.05). Puncture difficulty score (5-point): 2.0–2.7 (2.28±0.29) in group perfluorobutane, and 2.0–4.7 (2.95±0.85) in group sulfur hexafluoride, and the difference between the two groups was statistically significant ( P < 0.05). Enhanced imaging results within 3 months after surgery: complete ablation rate was 100% (25/25) in the group perfluorobutane, 95.2% (40/42 in the group sulfur hexafluoride), with no significant difference between the two groups ( P > 0.05). CONCLUSION: Perfluorobutane kupffer phase can make the operator accurately deploy the ablation needle and reduce the difficulty of operation.