Huang Wu

Dr. Huang Wu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2016 in Oncology Reports
Verified
Journal Article
Open access
PDF file
SLShu Liu
Shu Liu
CHChunmei Hu
Chunmei Hu
YWYingxue Wang
Yingxue Wang
GSGuang Shi
Guang Shi
YLYarong Li
Yarong Li
HWHuang Wu
Huang Wu
A growing body of evidence suggests that microRNA-124 (miR-124) functions as tumor-suppressor, and involves in tumor initiation, development and metastasis in major classes of human cancers; however, the biological role and underlying molecular mechanism of miR-124 in retinoblastoma (RB) remain unknown. Therefore, we investigated the biological activity and underlying molecular mechanism of miR-124 in human retinoblastoma. In the present study, our results demonstrated the downregulation of miR-124 in RB tissues and RB cell lines compared with normal retinal tissues. The ectopic expression of miR-124 in the RB cell lines (Y79 and SO-RB50) suppresses cell proliferation, migration and invasion, induced cell apoptosis in vitro. Furthermore, signal transducer and activator of transcription 3 (STAT3) was identified as a new target of miR-124, and overexpression of miR-124 decreased STAT3 expression on mRNA level and protein level in human RB cells. We also found that STAT3 mRNA expression was upregulated and inversely correlated with miR-124 expression in the RB tissues (r=-0.683; P<0.001). Restoration of the expression of STAT3 rescues the effects induced by miR-124 in RB cells. The findings of the present study suggested that miR-124 functioned as tumor suppressor in RB, at least in part, by targeting STAT3, and that it could serve as a potential candidate for RB therapeutics.

1 May 2019 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
LZLingzhi Zhao
Lingzhi Zhao
HWHuang Wu
Huang Wu
Background: Different methods to test stereopsis lead to different results. The aim of this study was to investigate the difference between stereoacuity tests using contour-based and random dot-based graphs at far and near distances. Methods: Thirty participants with normal visual acuity and stereopsis were recruited. Laptop equipment 3D shutter glasses were used to test distance stereoacuity and two 4K smartphones were used to test near stereoacuity with contour-based and random dot-based graphs. Results: No significant difference was found between contour-based and random-dot graphs regardless of the distance. Similarly, no significant difference between far and near distance was found for contour-based or random-dot graphs (Wilcoxon signed-rank test: P values were all >0.05). There was a high level of agreement between the methods using Bland-Altman statistical analysis. Conclusions: In a population with normal stereopsis, the stereoacuity is stable regardless of the test graphs used (contour-based or random-dot based) or the test distance (far or near).

26 April 2016 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
HWHuang Wu
Huang Wu
HJHan Jin
Han Jin
YSYing Sun
Ying Sun
YWYang Wang
Yang Wang
MGMin Ge
Min Ge
YCYunfeng Chi
Yunfeng Chi
To determine the stereoacuity threshold with a 3D laptop equipped with 3D shutter glasses, and to evaluate the effect of different shape and size of test symbols and different type of disparities to stereoacuity. Thirty subjects with a visual acuity in each eye of at least 0 logMAR and a stereoacuity of at least 32 arcsec (as assessed in Fly Stereo Acuity Test) were recruited. Three target symbols—tumbling "E", tumbling "C", and "□"—were displayed, each with six different sizes representing a visual acuity ranging from 0.5 to 0 logMAR when tested at 4.1 m, and with both crossed and uncrossed disparities. Two test systems were designed - fixed distance of 4.1 m and one for variable distance. The former has disparities ranging from 10 to 1000 arcsec. Each subject completed 36 trials to investigate the effect of different symbol sizes and shapes, and disparity types on stereoacuity. In the variable distance system, each subject was tested 12 times for the same purposes, both proximally and distally (the point where the 3D effect just appears and where it just disappears respectively), and the mean value was calculated from the mean proximal and distal distances. No significant difference was found among the groups in the fixed distance test system (Kruskal-Wallis test; Chi-square = 29.844, P = 0.715). Similarly, no significant difference was found in the variable distance system (Kruskal-Wallis test; proximal: Chi-square = 5.687, P = 0.338; distal: Chi-square = 5.898, P = 0.316; mean: Chi-square = 6.152, P = 0.292). Evaluating stereoacuity using this measurement system was convenient and effective. Changes in target shape and size and disparity types had no significant effect on stereoacuity. It would be helpful to choose optimal targets according to different purposes using computer-assisted 3D measurements.

20 May 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
LXLingxian Xu
Lingxian Xu
LLLu Liu
Lu Liu
HWHuang Wu
Huang Wu
Purpose: To investigate the influence of induced aniseikonia on stereopsis measured by contour-based and random-dot-based stereograms using a new method.Methods: Unlike previous studies in which aniseikonia was induced using magnifiers, which potentially influenced the position of the test symbols in the half-view, here the image was magnified while maintaining each test symbol’s central position within the half-view. A phoropter and two 4K smartphones were used to measure stereopsis in seventeen young adults aged 20–28 years old. Stereopsis was tested using both contour-based and random-dot-based stereograms under overall or meridional aniseikonia with magnifications ranging from 2.5 to 30%. Repeated measures ANOVA was used to evaluate the effect of aniseikonia on stereopsis.Results: Stereopsis decreased with an increase in aniseikonia magnification in the overall, horizontal, and vertical directions. Stereopsis values (log arcsec) increased from 1.29 ± 0.14 at baseline to 2.38 ± 0.16 with 30% overall aniseikonia of contour-based stereograms. In random-dot based stereograms, stereopsis values increased from 1.29 ± 0.16 at baseline to 2.24 ± 0.23 with 22.5% overall aniseikonia. Overall aniseikonia caused a significantly greater impairment on stereopsis as compared with the changes in meridional directions. In contour-based stereograms, vertical aniseikonia had significantly less impact on stereopsis than horizontal aniseikonia of identical magnification. The opposite phenomenon was found in random-dot-based stereograms.Conclusion: Stereopsis decreased with an increase of magnification of induced aniseikonia. Magnifying patterns (overall, horizontal, or vertical) also significantly affected stereopsis. The conflicting impact of meridional aniseikonia on stereopsis measured by contour-based and random-dot-based stereograms may be associated with the uniqueness of the two test systems.

1 March 2018 in Clinical and Experimental Optometry
Verified
Journal Article
Closed access
PDF file
HWHuang Wu
Huang Wu
SLShu Liu
Shu Liu
RWRuiqing Wang
Ruiqing Wang

1 January 2021 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
LLLu Liu
Lu Liu
LXLingxian Xu
Lingxian Xu
JWJunyue Wang
Junyue Wang
HWHuang Wu
Huang Wu
Owing to the limitations of printed stereoacuity tests, the effects of luminance and contrast on stereopsis have not yet been sufficiently investigated, despite its important implications in designing stereoacuity measuring instruments, particularly for electronic devices. A stereopsis measurement system was established using two 4 K smartphones and a phoropter to evaluate the effects of luminance and contrast variations on the stereoacuity test. Seventeen young subjects with normal visual acuity and stereopsis were recruited. Two types of test symbols, contour‐based and random‐dot‐based, were used in the experiment. Four series tests were established with different maximum brightness values, including 240 lux, 120 lux, 60 lux, and 30 lux. Each series test contained 19 pages with different contrasts between 95% and 5% and was calculated using the Michelson contrast formula. No significant difference was found for both contour‐based and random‐dot‐based stereograms in any of the contrast groups with different maximum brightness. Similarly, no significant difference was found between contour‐based and random‐dot‐based patterns under different contrasts of above 35%. As the contrast decreased below 30%, the stereopsis was significantly better in the contour‐based pattern than in the random‐dot‐based pattern for some degrees of contrast. The luminance and contrast of the digital display are not critical factors for stereoacuity under normal circumstances. This implies that a standard monitor with a certain 3D technology can be used to measure the stereoacuity threshold without calibrating the luminance and contrast.