Rapid technological improvements in biomaterials, computer-aided design (CAD) and manufacturing (CAM) have endorsed clear aligner therapy (CAT) as a mainstay of orthodontic treatment, and the materials employed for aligner fabrication play an all-important role in determining the clinical performance of clear aligners. This narrative review has attempted to comprehensively encompass the entire gamut of materials currently used for the fabrication of clear aligners and elucidate their characteristics that are crucial in determining their performance in an oral environment. Historical developments and current protocols in aligner fabrication, features of contemporary bioactive materials, and emerging trends related to CAT are discussed. Advances in aligner material chemistry and engineering possess the potential to bring about radical transformations in the therapeutic applications of CAT; in the absence of which, clear aligners would continue to underperform clinically, due to their inherent biomechanical constraints. Finally, while innovations in aligner materials such as shape memory polymers, direct three-dimensional (3D) printed clear aligners and bioactive materials combined with clear aligner materials are essential to further advance the applications of CAT; increased awareness of environmental responsibilities among aligner manufacturers, aligner prescribing clinicians and aligner users is essential for better alignment of our climate change goals towards a sustainable planet.
19 November 2018 in Journal of Healthcare Engineering
Cephalometric analysis is a standard tool for assessment and prediction of craniofacial growth, orthodontic diagnosis, and oral-maxillofacial treatment planning. The aim of this study is to develop a fully automatic system of cephalometric analysis, including cephalometric landmark detection and cephalometric measurement in lateral cephalograms for malformation classification and assessment of dental growth and soft tissue profile. First, a novel method of multiscale decision tree regression voting using SIFT-based patch features is proposed for automatic landmark detection in lateral cephalometric radiographs. Then, some clinical measurements are calculated by using the detected landmark positions. Finally, two databases are tested in this study: one is the benchmark database of 300 lateral cephalograms from 2015 ISBI Challenge, and the other is our own database of 165 lateral cephalograms. Experimental results show that the performance of our proposed method is satisfactory for landmark detection and measurement analysis in lateral cephalograms.
The development of facial scanners has improved capabilities to create three-dimensional (3D) virtual patients for accurate facial and smile analysis. However, most of these scanners are expensive, stationary and involve a significant clinical footprint. The use of the Apple iPhone and its integrated “TrueDepth” near-infrared (NIR) scanner combined with an image processing application (app) offers the potential to capture and analyze the unique 3D nature of the face; the accuracy and reliability of which are yet to be established for use in clinical dentistry. This study was designed to validate both the trueness and precision of the iPhone 11 Pro smartphone TrueDepth NIR scanner in conjunction with the Bellus3D Face app in capturing 3D facial images in a sample of adult participants in comparison to the conventional 3dMDface stereophotogrammetry system. Twenty-nine adult participants were prospectively recruited. Eighteen soft tissue landmarks were marked on each participant's face before imaging. 3D facial images were captured using a 3dMDface system and the Apple iPhone TrueDepth NIR scanner combined with the Bellus3D Face app respectively. The best fit of each experimental model to the 3dMD scan was analyzed using Geomagic Control X software. The root mean square (RMS) was used to measure the “trueness” as the absolute deviation of each TrueDepth scan from the reference 3dMD image. Individual facial landmark deviations were also assessed to evaluate the reliability in different craniofacial regions. The “precision” of the smartphone was tested by taking 10 consecutive scans of the same subject and comparing those to the reference scan. Intra-observer and inter-observer reliabilities were assessed using the intra-class correlation coefficient (ICC). Relative to the 3dMDface system, the mean RMS difference of the iPhone/Bellus3D app was 0.86 ± 0.31 mm. 97% of all the landmarks were within 2 mm of error compared with the reference data. The ICC for intra-observer reproducibility or precision of the iPhone/Bellus3D app was 0.96, which was classified as excellent. The ICC for inter-observer reliability was 0.84, which was classified as good. These results suggest that 3D facial images acquired with this system, the iPhone TrueDepth NIR camera in conjunction with the Bellus3D Face app, are clinically accurate and reliable. Judicious use is advised in clinical situations that require high degrees of detail due to a lack of image resolution and a longer acquisition time. Generally, this system possesses the potential to serve as a practical alternative to conventional stereophotogrammetry systems for use in a clinical setting due to its accessibility and relative ease of use and further research is planned to appraise its updated clinical use.
Objectives: To compare palatal dimensions and molar inclinations after Invisalign First System (IFS) to those in patients treated with slow maxillary expansion (SME) and normal controls. Materials and Methods: Twenty-three mixed dentition patients treated with IFS were gender- and dental age-matched to another two groups: Haas-type SME and control group. The intercanine width (ICW), intermolar width (IMW), palatal surface area (SA), volume (V), and first molar buccolingual inclinations (MI) were measured before (T1) and after (T2) treatment. Analysis of variance was used to compare the differences among the three groups. Results: The ICW increased significantly by 3.10 mm after IFS, 4.77 mm with SME, and 0.54 mm in controls; the difference among the groups was statistically significant ( P < .001). The IMW increased by 1.95 mm in IFS, 4.76 mm in SME, and 0.54 mm in controls, with significant intra- and intergroup differences. Palatal SA and volume increased by 43.50 mm 2 and 294.85 mm 3 in the IFS group, which differed significantly from SME, but was similar to controls. The right and left MI increased 0.24° and 0.08° buccally, respectively, in the IFS group, which was comparable to controls, while significantly increased buccal MI was observed in the SME group. Conclusions: IFS expands the upper arch with increased ICW and IMW compared to controls, but the expansion amount is smaller than SME. Unlike SME, IFS has no effects on palatal dimensions and molar inclinations.
9 January 2024 in Frontiers in Bioengineering and Biotechnology
Introduction: Clear aligners, while offering a more hygienic alternative to fixed appliances, are still associated with challenges including plaque accumulation and enamel demineralization. The aim of the present study was to investigate the antibiofilm and remineralization effectiveness of innovative flowable composite attachments containing bioceramic micro-fillers.Methods: Four experimental attachments were formulated and bonded to human enamel specimens: 3M Filtek Supreme flowable composite (Filtek SF) + 10% bioactive glass 45S5 (BAG), Filtek SF + 30% BAG, Filtek SF + 10% Bredigite (BRT), Filtek SF + 30% BRT. Plaque biofilms were grown on the bonded enamel using a standardized protocol and the biofilm-killing effect was assessed by confocal laser scanning microscopy and scanning electron microscopy. Vickers microhardness was measured to evaluate the remineralization effect of the attachments containing bioceramic fillers after acid challenge. Shear bond test was performed to assess the bonding strength.Results: Attachments with bioceramic fillers significantly inhibited plaque biofilm growth in 3 weeks on enamel, contributing over 20% bacterial cell killing in 10% filler groups and over 30% killing in 30% filler groups. All four experimental groups demonstrated significantly higher microhardness values than the control group without fillers on the attachment side. The shear bonding strength was not compromised in the attachments with micro-fillers.Discussion: Proper incorporation of bioceramic micro-fillers in attachments provides an innovative approach for clear aligner therapy with reinforced antibiofilm and remineralization effects without weakening shear bonding strength.