This paper proposes a variable-power-tracking-operation-based frequency regulation scheme for a wind turbine generator (WTG) that employs a frequency-excursion-based control parameter to suppress frequency excursion under various wind speeds and disturbances. To this end, an improved system frequency response model is built, and then the frequency regulation characteristics of the WTG are investigated. The frequency-excursion-based control parameter is determined. Simulations based on the Matlab/Simulink simulator verify the effectiveness of the proposed variable-power-tracking-operation-based frequency regulation strategy. The simulation results clearly indicate that the suggested scheme is beneficial for reducing the maximum frequency deviation. The proposed frequency regulation scheme could enhance the networking capacity of wind farms and improve the capacity of the power grid to absorb renewable energy.
To realize the coordinated distribution of power in the multi-source system, maintain the charging balance among energy storage units, and improve the anti-interference capability of the bus voltage, a cascade control for an isolated PV-battery DC microgrid is proposed in this paper. First, to provide inertia for the microgrid so that it can cope with external disturbance, the parameters of the droop curve were adjusted by correlating the bus voltage variation rate, which improved the conventional droop control. Secondly, a nonsingular terminal sliding mode control was proposed to track voltage and current references and, thus, enhance the robustness of the DC microgrid. Moreover, the high-frequency chattering of the sliding mode control was inhibited with the exponential reaching law, and the Lyapunov function was utilized to verify the stability of the proposed nonsingular terminal sliding mode control method. Both the simulated and experimental results verified the correctness and effectiveness of the proposed method.
With an emphasis placed on a low-carbon economy, photovoltaic grid-connected inverters are moving toward the center of the stage. In order to address the problems related to the strong parameter dependence of the conventional model’s predictive control in grid-connected inverters, an improved parameter-free predictive current control is proposed. Relying on an extended state observer, an ultralocal model is employed to predict future currents without any parameters. The system can achieve a satisfactory performance in terms of dynamic response and robustness. Additionally, 30 virtual voltage vectors are extended for lower current ripples, which is followed by the use of a triangle candidate strategy to significantly ease the computing burden. In general, the proposed strategy omits parameter dependence, complex tuning work, and large tracking errors. The effectiveness of the proposed model is verified through the experimental results.