Chen Wang

Dr. Chen Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2022 in Entropy
Verified
Journal Article
Open access
PDF file
CWChen Wang
Chen Wang
Lei WangLei Wang
Lei Wang
In this paper, a wet steam model is utilized to study the fluid characteristic and performance of a supersonic ejector. The condensation process, which has been ignored by most researchers, is analyzed in detail. It is found that the most intensive condensation happens at the primary nozzle downstream and nozzle exit region. Moreover, the impacts of primary flow pressure and back pressure on ejector performance are studied by the distribution of Mach number inside the ejector. Furthermore, the results show that the secondary mass flow rate first grows sightly then remains almost unchanged, while the primary mass flow rate rises sharply and ejector entrainment ratio drops dramatically with the increase in primary flow pressure.

10 November 2022 in Entropy
Verified
Journal Article
Open access
PDF file
MYMeihong Yu
Meihong Yu
CWChen Wang
Chen Wang
Lei WangLei Wang
Lei Wang
HZHongxia Zhao
Hongxia Zhao
With the increasingly serious energy and environmental problems, the R1234yf ejector refrigeration system (ERS) shows great development potential in the refrigeration industry due to its simplicity, low maintenance costs and environmentally friendly nature. However, poor ejector performance has always been the main bottleneck for system applications. In order to overcome this problem, this paper proposes a design method for R1234yf ejectors based on the gas dynamic method and optimizes the geometrical parameters including the area ratio (AR) and nozzle exit position (NXP) to improve its performance through the control variable optimization algorithms. Based on the validated simulation model, the results show that the entrainment ratio increases initially and then decreases with the increase in AR and NXP, respectively; the AR has a significant effect on the shock wave position in the mixing chamber and the NXP can directly influence the expansion state of motive fluid; the ejector performance increases by about 17% over the initial entrainment ratio by the control variable optimization algorithms. This work can guide the R1234yf ejector design and promote the development of the ERS with environmentally friendly working fluids.

13 March 2024 in Inventions
Verified
Journal Article
Open access
PDF file
KLKejing Li
Kejing Li
CWChen Wang
Chen Wang
JLJingjing Li
Jingjing Li
Lei WangLei Wang
Lei Wang
ZLZongji Li
Zongji Li
CZChuanlong Zhang
Chuanlong Zhang
Hydrogen recirculation systems (HRSs) are vital components of proton exchange membrane fuel cells (PEMFCs), and it is necessary to investigate different HRS schemes to meet the needs of high-power PEMFCs. PEMFCs are developing in the direction of low cost, high power, wide working conditions, low noise, compact structure, etc. Currently, it is difficult for hydrogen recirculation pumps (HRPs) to meet the flow requirements of high-power PEMFCs. HRPs inevitably have high parasitic energy consumption, loud noise output, high cost, easy leakage, and high failure rates. Therefore, it is necessary to study different HRS schemes to develop a better solution for high-power PEMFCs. In this study, the functional prototype of a piping and instrumentation diagram (P&ID) based on three HRSs of HRPs was designed, and a functional prototype was built. Working according to the analysis and comparison of PEMFC performance test data, we find that the net power trend of PEMFC systems using three different HRS technology schemes is consistent. The ejector scheme and the combination scheme do not reduce the performance of PEMFCs and have advantages in different power ranges, such as 24 A, 48 A, and other small current points. The PEFMC system net power order is as follows: ejector scheme > HRP scheme > combination scheme. At about 120 A, the net power outputs of the three HRS schemes in the PEMFC system coincide. From around 180 A onwards, the PEMFC system power of the combined HRS scheme gradually dominates. At 320 A, the PEFMC system net power order is as follows: combined HRS scheme > HRP scheme > ejector scheme.

21 December 2022 in Entropy
Verified
Journal Article
Open access
PDF file
JYJia Yan
Jia Yan
RLRuixin Li
Ruixin Li
CWChen Wang
Chen Wang
In this paper, three key geometrical dimensions such as XL3 (constant pressure mixing chamber length), D5 (diameter of the throat of the ejector), and XL5 (length of the throat of the ejector) were separately or sequentially optimized under different lengths and angles of two sections of the primary nozzle. Furthermore, shock cluster number and shock chain length or area of low static pressure zone were used to analyze the effect of geometries on ejector performance, which is normally indicated by entrainment ratio (ER, or the ratio between the mass flow rate of secondary flow and the mass flow rate of primary flow). The results show that: (1) the improvement of ejector performance with only optimization of the primary nozzle is quite limited, in comparison, the impact of length and angle of nozzle diverging section on ejector performance is higher than that of converging section; (2) the relative sensitivity of ER to three key dimensions is much higher than that to the angles and lengths of the primary nozzle; (3) with the increase of XL3 and D5, ER needs a larger angle and smaller length of nozzle converging section; (4) the impact of key geometries on ejector performance can be analyzed with the help of shock cluster number and shock chain length or area of low static pressure zone.

14 September 2022 in Entropy
Verified
Journal Article
Open access
PDF file
JYJia Yan
Jia Yan
CWChen Wang
Chen Wang
This study presents an experimental rig of a multi-evaporator refrigeration system, in which the pressure difference between two evaporators can be maintained by using both the pressure-regulating valve (PRV) and electronic expansion valve (EEV)-based ejector. The proposed EEV-based ejector that is used to partially recover the throttling losses of the PRV consists of an EEV and the main body of an ejector. The established experimental system can work in both PRV-based mode and ejector-based mode by switching the valves. Via experimental means, the performances of both modes were evaluated by varying the cooling loads. Moreover, the effects of the spindle-blocking area percentage of the EEV-based ejector and the condensing temperature on the system performance were identified. The results showed that: (1) the system performance of the ejector-based mode was 3.6% higher than the PRV-based mode; (2) both entrainment ratio and coefficient of performance dropped along with the increase in ejector spindle-blocking area percentage; (3) compared to ejector spindle-blocking area percentage, the condensing temperature had a more evident influence on the system performance.

18 December 2022 in Entropy
Verified
Journal Article
Open access
PDF file
JYJia Yan
Jia Yan
YSYuetong Shu
Yuetong Shu
CWChen Wang
Chen Wang
In this paper, for a highly coupled two-stage ejector-based cooling cycle, the optimization of primary nozzle length and angle of the second-stage ejector under varied primary nozzle diameters of the second stage was conducted first. Next, the evaluation for the influence of variable back pressure on ER of the two-stage ejector was performed. Last, the identification of the effect of the variable back pressure on the key geometries of the two-stage ejector was carried out. The results revealed that: (1) with the increase of the nozzle diameter at the second stage, the ER of both stages decreased with the increases of the length and angle of the converging section of the second-stage primary nozzle; (2) the pressure lift ratio range of the second-stage ejector in the critical mode gradually increased with the increase of the nozzle diameter of the second-stage; (3) when the pressure lift ratio increased from 102% to 106%, the peak ER of the second-stage decreased, and the influence of the area ratio and nozzle exit position of the second-stage ejector on its ER was reduced; (4) with the increase of nozzle diameter of the second-stage, the influence of area ratio and nozzle exit position of the second-stage on the second-stage performance decreased; and (5) the optimal AR of the second stage decreased but the optimal nozzle exit position of the second stage kept constant with the pressure lift ratio of the two-stage ejector.