Interdisciplinary orthogeriatric care of older adult hip fracture patients is of growing importance due to an ageing population, yet there is ongoing disagreement about the most effective model of care. This study aimed to compare different forms of orthogeriatric treatment, with focus on their impact on postoperative mobilization, mobility and secondary fracture prevention. In this observational cohort study, patients aged 70 years and older with a proximal femur fracture requiring surgery, were included from 1 January 2016 to 31 December 2019. Data were recorded from hospital stay to 120-day follow-up in the Registry for Geriatric Trauma (ATR-DGU), a specific designed registry for older adult hip fracture patients. Of 23,828 included patients from 95 different hospitals, 72% were female, median age was 85 (IQR 80–89) years. Increased involvement of geriatricians had a significant impact on mobilization on the first day (OR 1.1, CI 1.1–1.2) and mobility seven days after surgery (OR 1.1, CI 1.1–1.2), initiation of an osteoporosis treatment during in-hospital stay (OR 2.5, CI 2.4–2.7) and of an early complex geriatric rehabilitation treatment (OR 1.3, CI 1.2–1.4). These findings were persistent after 120 days of follow-up. Interdisciplinary treatment of orthogeriatric patients is beneficial and especially during in-patient stay increased involvement of geriatricians is decisive for early mobilization, mobility and initiation of osteoporosis treatment. Standardized treatment pathways in certified geriatric trauma departments with structured data collection in specific registries improve outcome monitoring and interpretation.
Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri-implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri-implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri-implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri-implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. Statement of Significance: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n=8 titanium and n=8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.
Posttraumatic shoulder stiffness remains a problem after proximal humerus fracture (PHF) despite good healing rates. The aim of this pilot study was to determine whether the implant material and overlying soft tissue have an effect on shoulder range of motion (ROM) before and after implant removal (IR). 16 patients (mean age 55.2 ± 15.3 (SD) years; 62.5% female) were included who underwent operative treatment with locking plates of either carbon fiber reinforced Polyetheretherketone (PEEK) (PEEKPower® humeral fracture plate, Arthrex, Naples, Florida, USA, n = 8) or titanium alloy (Ti) (Philos®, DePuy Synthes, Johnson & Johnson Medical, Raynham, Massachusetts, USA, n = 8) for PHF. All patients presented with a limited ROM and persistent pain in everyday life after the fracture had healed, whereupon IR was indicated. ROM before and after IR were compared as well as the Constant Score (CS) and the CS compared to the contralateral shoulder (%CS) 1 year after IR. In group PEEK, elevation was 116.3° ± 19.2° pre- and 129.4° ± 23.7° post-IR (p = 0.027). External rotation was 35.0° ± 7.6° pre- and 50.6° ± 21.8° post-IR (p = 0.041). External rotation with the humerus abducted 90° was 38.8° ± 18.1° pre- and 52.5° ± 25.5° post-IR (p = 0.024). In group Ti, elevation was 110.0° ± 34.6° pre- and 133.8° ± 31.1° post-IR (p = 0.011). External rotation with the humerus at rest was 33.8° ± 23.1° pre- and 48.8° ± 18.7° post-IR (p = 0.048). External rotation with the humerus abducted 90° was 40.0° ± 31.6° pre- and 52.5° ± 22.5° post-IR (p = 0.011). Comparison of the two implant materials showed no significant difference. The overall CS was 90.3 ± 8.8, the %CS was 91.8% ± 14.7%. There was no significant difference in ROM, CS and %CS with respect to plate materials, although lower cell adhesion is reported for the hydrophobic PEEK. However, all patients showed improved functional outcomes after IR in this pilot study. In patients with shoulder stiffness following locked plating for PHF, implants should be removed and open arthrolysis should be performed, independently from the hardware material. II