Christakis Damianou

Prof. Dr. Christakis Damianou

Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 1997 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
Christakis DamianouChristakis Damianou
Christakis Damianou
NSNarendra T. Sanghvi
Narendra T. Sanghvi
FFFrancis J. Fry
Francis J. Fry
RMRoberto Maass-Moreno
Roberto Maass-Moreno
The effect of temperature and thermal dose (equivalent minutes at 43 °C) on ultrasonic attenuation in fresh dog muscle, liver, and kidney in vitro, was studied over a temperature range from room temperature to 70 °C. The effect of temperature on ultrasonic absorption in muscle was also studied. The attenuation experiments were performed at 4.32 MHz, and the absorption experiments at 4 MHz. Attenuation and absorption increased at temperatures higher than 50 °C, and eventually reached a maximum at 65 °C. The rate of change of tissue attenuation as a function of temperature was between 0.239 and 0.291 Np m−1 MHz−1 °C−1 over the temperature range 50–65 °C. A change in attenuation and absorption was observed at thermal doses of 100–1000 min, where a doubling of these loss coefficients was observed over that measured at 37 °C, presumably the result of changes in tissue composition. The maximum attenuation or absorption was reached at thermal dosages on the order of 107 min. It was found that the rate at which the thermal dose was applied (i.e., thermal dose per min) plays a very important role in the total attenuation absorption. Lower thermal dose rates resulted in larger attenuation coefficients. Estimations of temperature-dependent absorption using a bioheat equation based thermal model predicted the experimental temperature within 2 °C.

1 January 1995 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
NVN.I. Vykhodtseva
N.I. Vykhodtseva
KHK. Hynynen
K. Hynynen
Christakis DamianouChristakis Damianou
Christakis Damianou

1 October 1996 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
RMRoberto Maass-Moreno
Roberto Maass-Moreno
Christakis DamianouChristakis Damianou
Christakis Damianou
Temperature changes in tissue, caused by high-intensity focused ultrasound, cause time shifts in the echoes that traverse the heated tissue. These time shifts are caused by thermally induced changes in the distribution of the velocity of sound and by thermal expansion within the tissue. Our analytical model relates these shifts to changes in temperature distribution. It is proposed that these relationships can be used as a method for the noninvasive estimation of temperature within the tissue. The model shows that the echo shifts depend mostly on changes in the mean velocity along the acoustical path of the echoes and that no explicit information about the shape of the velocity distribution is required. The effects of the tissue thermal expansion are small in comparison, but may be significant under certain conditions. The theory, as well as numerical simulations, also predicts that the time shifts have an approximately linear behavior as a function of temperature. This suggests that an empirical linear delay–temperature relationship can be determined for temperature prediction. It is also shown that, alternatively, the distribution of temperature in the tissue can be estimated from the distribution of echo delays along the acoustical path. In the proposed system, low-level pulse echoes are sampled during brief periods when the high-intensity ultrasonic irradiation is off, and thus linear acoustic behavior is assumed. The possibility of nonlinear aftereffects and other disturbances limiting this approach is discussed.

1 March 1994 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Christakis DamianouChristakis Damianou
Christakis Damianou
KHK. Hynynen
K. Hynynen
The purpose of this study was to test the concept of using calculated thermal dose as a predictor for the necrosed tissue volume. A parametric study was conducted where the sonication parameters (pulse duration, power), transducer parameters (frequency, F number) and tissue properties (perfusion rate, attenuation) were varied and their effect on the lesion size was investigated. In vivo experiments where a focused ultrasound beam was used to induce tissue necrosis in thigh muscle of dog and rabbit were also conducted to obtain the reliability of the predictions. The experimental and simulated lesion sizes compared well. From the parametric study the threshold intensity for 1‐ and 5‐s sonications were found to be about 1000 and 400 W/cm2, respectively. It was found that the lesion size was practically perfusion independent for pulses 5 s or shorter. The lesion size increases with increased pulse duration, acoustical power, and F number, but decreases with increased frequency provided that the focal intensity is kept constant. It was found also that the deeper the focus is in the tissue, the smaller the frequency range that causes selective tissue necrosis in the focal zone.

1 October 1996 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
RMRoberto Maass-Moreno
Roberto Maass-Moreno
Christakis DamianouChristakis Damianou
Christakis Damianou
NSNarendra T. Sanghvi
Narendra T. Sanghvi
Time shifts in echo signals returning from a heated volume of tissue correlate well with the temperature changes. In this study the relationship between these time shifts (or delays) and the tissue temperature was investigated in excised muscle tissue (turkey breast) as a possible dosimetric method. Heat was induced by the repeated activation of a sharply focused high-intensity ultrasound beam. Pulse echoes were sent and received with a confocal diagnostic transducer during the brief periods when the high-intensity ultrasonic beam was inactive. The change in transit time between echoes collected at different temperatures was estimated using cross-correlation techniques. With spatial-peak temporal-peak intensities (ISPTP) of less than 950W/cm2, the delay versus temperature relationship was fit to a linear equation with highly reproducible coefficients. The results confirmed that for spatial-peak temperature increases of approximately 10 degrees C, temperature-dependent changes in velocity were the single most important factor determining the observed delay, and a linear approximation could produce accurate temperature estimations. Nonlinear phenomena that occurred during the high-intensity irradiation had no significant effect on the measured delay. At ISPTP of 1115-2698 W/cm2, the delay-temperature relationship showed a similar monotonically decreasing pattern, but as the temperature peaked its slope gradually increased. This may reflect the curvilinear nature of the velocity-temperature relationship, but it may also be related to irreversible tissue modifications and to the use of the spatial-peak temperature to experimentally characterize the temperature changes. Overall, the results were consistent with theoretical predictions and encourage further experimental work to validate other aspects of the technique.

1 January 1993 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Christakis DamianouChristakis Damianou
Christakis Damianou
KHK. Hynynen
K. Hynynen