Mingpeng Yang

Prof. Dr. Mingpeng Yang

Nanjing University of Information Science and Technology, Nanjing, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2023 in ACS Sensors
Verified
Journal Article
Closed access
Mingpeng YangMingpeng Yang
Mingpeng Yang
NSNan Sun
Nan Sun
XLXiaochen Lai
Xiaochen Lai
JWJiamin Wu
Jiamin Wu
LWLifan Wu
Lifan Wu
Lihang FengLihang Feng
Lihang Feng

22 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
XLXiaochen Lai
Xiaochen Lai
Mingpeng YangMingpeng Yang
Mingpeng Yang
HWHao Wu
Hao Wu
DLDachao Li
Dachao Li
This review mainly studies the development status, limitations, and future directions of modular microfluidic systems. Microfluidic technology is an important tool platform for scientific research and plays an important role in various fields. With the continuous development of microfluidic applications, conventional monolithic microfluidic chips show more and more limitations. A modular microfluidic system is a system composed of interconnected, independent modular microfluidic chips, which are easy to use, highly customizable, and on-site deployable. In this paper, the current forms of modular microfluidic systems are classified and studied. The popular fabrication techniques for modular blocks, the major application scenarios of modular microfluidics, and the limitations of modular techniques are also discussed. Lastly, this review provides prospects for the future direction of modular microfluidic technologies.

26 July 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Mingpeng YangMingpeng Yang
Mingpeng Yang
NSnan sun
nan sun
XLXiaochen Lai
Xiaochen Lai
YLYanjie Li
Yanjie Li
XZXingqiang Zhao
Xingqiang Zhao
WZWangping Zhou
Wangping Zhou
Human sweat is intricately linked to human health, and unraveling its secrets necessitates a substantial volume of experimental data. However, conventional sensors fabricated via complex processes such as photolithography offer high detection precision at the expense of prohibitive costs. In this study, we presented a cost-effective and high-performance wearable flexible sweat sensor for real-time monitoring of K+ and Na+ concentrations in human sweat, fabricated using screen printing technology. Initially, we evaluated the electrical and electrochemical stability of the screen-printed substrate electrodes, which demonstrated good consistency with a variation within 10% of the relative standard deviation (RSD), meeting the requirements for reliable detection of K+ and Na+ in human sweat. Subsequently, we employed an “ion-electron” transduction layer and an ion-selective membrane to construct the sensors for detecting K+ and Na+. Comprehensive tests were conducted to assess the sensors’ sensitivity, linearity, repeatability, resistance to interference, and mechanical deformation capabilities. Furthermore, we evaluated their long-term stability during continuous monitoring and storage. The test results confirmed that the sensor’s performance indicators, as mentioned above, met the requirements for analyzing human sweat. In a 10-day continuous and regular monitoring experiment involving volunteers wearing the sensors, a wealth of data revealed a close relationship between K+ and Na+ concentrations in human sweat and hydration status. Notably, we observed that consistent and regular physical exercise effectively enhanced the body’s resistance to dehydration. These findings provided a solid foundation for conducting extensive experiments and further exploring the intricate relationship between human sweat and overall health. Our research paved a practical and feasible path for future studies in this domain.

1 May 2022 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
Mingpeng YangMingpeng Yang
Mingpeng Yang
NSNan Sun
Nan Sun
YLYong Luo
Yong Luo
XLXiaochen Lai
Xiaochen Lai
PLPeiru Li
Peiru Li
ZZZhenyu Zhang
Zhenyu Zhang
Bubbles in microfluidics—even those that appear to be negligibly small—are pervasive and responsible for the failure of many biological and chemical experiments. For instance, they block current conduction, damage cell membranes, and interfere with detection results. To overcome this unavoidable and intractable problem, researchers have developed various methods for capturing and removing bubbles from microfluidics. Such methods are multifarious and their working principles are very different from each other. In this review, bubble-removing methods are divided into two broad categories: active debubblers (that require external auxiliary equipment) and passive debubblers (driven by natural processes). In each category, three main types of methods are discussed along with their advantages and disadvantages. Among the active debubblers, those assisted by lasers, acoustic generators, and negative pressure pumps are discussed. Among the passive debubblers, those driven by buoyancy, the characteristics of gas–liquid interfaces, and the hydrophilic and hydrophobic properties of materials are discussed. Finally, the challenges and prospects of the bubble-removal technologies are reviewed to refer researchers to microfluidics and inspire further investigations in this field.

28 December 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Mingpeng YangMingpeng Yang
Mingpeng Yang
NSNan Sun
Nan Sun
XLXiaochen Lai
Xiaochen Lai
XZXingqiang Zhao
Xingqiang Zhao
WZWangping Zhou
Wangping Zhou
Sweat, commonly referred to as the ultrafiltrate of blood plasma, is an essential physiological fluid in the human body. It contains a wide range of metabolites, electrolytes, and other biologically significant markers that are closely linked to human health. Compared to other bodily fluids, such as blood, sweat offers distinct advantages in terms of ease of collection and non-invasive detection. In recent years, considerable attention has been focused on wearable sweat sensors due to their potential for continuous monitoring of biomarkers. Electrochemical methods have been extensively used for in situ sweat biomarker analysis, as thoroughly reviewed by various researchers. This comprehensive review aims to provide an overview of recent advances in non-electrochemical methods for analyzing sweat, including colorimetric methods, fluorescence techniques, surface-enhanced Raman spectroscopy, and more. The review covers multiple aspects of non-electrochemical sweat analysis, encompassing sweat sampling methodologies, detection techniques, signal processing, and diverse applications. Furthermore, it highlights the current bottlenecks and challenges faced by non-electrochemical sensors, such as limitations and interference issues. Finally, the review concludes by offering insights into the prospects for non-electrochemical sensing technologies. By providing a valuable reference and inspiring researchers engaged in the field of sweat sensor development, this paper aspires to foster the creation of innovative and practical advancements in this domain.

17 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Mingpeng YangMingpeng Yang
Mingpeng Yang
YLyongquan Liu
yongquan Liu
WYWenjing Yang
Wenjing Yang
JLJia Liu
Jia Liu
Real-time monitoring of human joint motion holds paramount importance in assessing joint health status, preventing and treating joint diseases, and evaluating physical flexibility and coordination. However, traditional strain sensors face limitations in meeting the substantial strain requirements associated with human joint motion. Recently, there has been considerable attention directed towards flexible strain sensors prepared using pliable substrates combined with silk and cotton fabrics. Nonetheless, these sensors exhibit insufficient linearity across the entire measurement range, thereby compromising the predictability of real joint motion based on the output signal. This paper introduced a flexible strain sensor designed to address this issue by offering an enhanced range and high linearity. Specifically, the core wire of the strain sensor was produced by coating a polybutylene terephthalate thread with conductive carbon ink integrated with carbon nanotubes, encapsulated in a thin layer of polydimethylsiloxane in an “S” configuration. The proposed strain sensor maintained excellent linearity within its strain range of 60%, along with advantages such as rapid response speed and robust durability. On-trial tests further affirmed the sensor’s capability to effectively monitor the motion of human joints.