Tamon Kabata

Dr. Tamon Kabata


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2015 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
KKKazunari Kuroda
Kazunari Kuroda
TKTamon Kabata
Tamon Kabata
KHKatsuhiro Hayashi
Katsuhiro Hayashi
TMToru Maeda
Toru Maeda
YKYoshitomo Kajino
Yoshitomo Kajino
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya
This study aimed to determine whether intra-articularly injected adipose-derived stem cells (ADSCs) inhibited articular cartilage degeneration during osteoarthritis (OA) development in a rabbit anterior cruciate ligament transection (ACLT) model. The paracrine effects of ADSCs on chondrocytes were investigated using a co-culture system. ACLT was performed on both knee joints of 12 rabbits. ADSCs were isolated from the subcutaneous adipose tissue. ADSCs with hyaluronic acid were intra-articularly injected into the left knee, and hyaluronic acid was injected into the right knee. The knees were compared macroscopically, histologically, and immunohistochemically at 8 and 12 weeks. In addition, cell viability was determined using co-culture system of ADSCs and chondrocytes. Macroscopically, osteoarthritis progression was milder in the ADSC-treated knees than in the control knees 8 weeks after ACLT. Histologically, control knees showed obvious erosions in both the medial and lateral condyles at 8 weeks, while cartilage was predominantly retained in the ADSC-treated knees. At 12 weeks, the ADSC-treated knees showed a slight suppression of cartilage degeneration, unlike the control knees. Immunohistochemically, MMP-13 expression was less in the ADSC-treated cartilage than in the control knees. The cell viability of chondrocytes co-cultured with ADSCs was higher than that of chondrocytes cultured alone. TNF-alpha-induced apoptotic stimulation was similar between the two groups. Intra-articularly injected ADSCs inhibited cartilage degeneration progression by homing to the synovium and secreting a liquid factor having chondro-protective effects such as chondrocyte proliferation and cartilage matrix protection.

31 October 2016 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
KHKazuhiro Hasegawa
Kazuhiro Hasegawa
TKTamon Kabata
Tamon Kabata
YKYoshitomo Kajino
Yoshitomo Kajino
DIDaisuke Inoue
Daisuke Inoue
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya
Periprosthetic fractures of the acetabulum occurring during primary THA are rare. Periprosthetic occult fractures are defined as those not identified by the surgeon during the procedure which might be missed on a routine postoperative radiograph. However, it is unclear how frequently these fractures occur and whether their presence affects functional recovery. In this study, using routine CT scans that were obtained as part of another primary hip arthroplasty study protocol, we retrospectively assessed (1) the prevalence of occult fractures of the acetabulum occurring during primary THA, (2) the location of occult fractures of the acetabulum during THA, and (3) risk factors contributing to such occult fractures. Between 2004 and 2013, our institute performed 585 primary THAs (cementless or hybrid) in 494 patients with DICOM pre- and postoperative CT; during the period in question, all patients undergoing THA underwent CT before and after surgery. Preoperative CT images were taken as part of a CT-based three-dimensional templating software and navigation system. Postoperative CT images were taken an average of 1 week after surgery as part of a different protocol to evaluate cup position, restoration of leg length and offset, volume of postoperative hematoma to assess anticoagulation effects after THA, and fractures that were not found on routine postoperative radiographs (which we defined as occult fractures). Patients with a history of prior pelvic osteotomy, trauma, and infection were excluded (88 patients/99 hips); 406 patients (102 males and 304 females; 486 hips) form the basis of this report. The mean age of the patients was 60 ± 11 years, with a mean BMI of 23 ± 4 kg/m2. The mean followup of the patients with periprosthetic fracture of the acetabulum was 58 ± 28 months (range, 12–131 months). Potential risk factors for occult acetabular fracture including age, sex, BMI, preoperative diagnosis, additional dome screw fixation, composition and size of each cup, and acetabular design were examined in multivariate analysis. Acetabular component designs were categorized as true hemispheric, peripheral self-locking, and elliptical; during the period in question the indications for each cup design were based on the brand of stem used. Comparison between preoperative and postoperative CT images was done to detect the fractures. Patients with fractures identified during surgery were treated with additional dome screw fixation and a 3-week period of nonweightbearing. Patients with occult fractures in this series did not receive additional treatment as we had confirmed secure fixation of the cup during surgery. Occult fractures occurred in 41 hips (8.4%); periprosthetic fractures of the acetabulum were seen during surgery in an additional two hips (0.4%). The superolateral wall was the most frequent location for occult fractures of the acetabulum. After controlling for relevant confounding variables, only the use of peripheral self-locking cups was associated with an increased risk of occult fracture (odds ratio [OR], 2.6 compared with hemispheric cups; 95% CI, 1.2–5.6; p < 0.05). All patients with occult fractures showed bone ingrowth fixation at the final followup, without any additional surgical intervention. Periprosthetic occult fractures of the acetabulum may occur relatively frequently during press-fit impaction. We observed a higher rate of fractures associated with the use of peripheral self-locking components. Occult acetabular fractures not detected on routine postoperative plain films may be ignored if secure fixation of the cup has been confirmed during the operation. Level III, therapeutic study.

1 January 2015 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
PDF file
DIDaisuke Inoue
Daisuke Inoue
TKTamon Kabata
Tamon Kabata
TMToru Maeda
Toru Maeda
YKYoshitomo Kajino
Yoshitomo Kajino
KFKenji Fujita
Kenji Fujita
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya

25 February 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YSYoshitomo Saiki
Yoshitomo Saiki
TKTamon Kabata
Tamon Kabata
TOTomohiro Ojima
Tomohiro Ojima
YKYoshitomo Kajino
Yoshitomo Kajino
DIDaisuke Inoue
Daisuke Inoue
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measuring hip-knee-ankle (HKA) angle in patients with knee osteoarthritis, by comparing it with radiography. In this prospective study, we analysed 60 knees (30 patients) with knee osteoarthritis. We measured HKA angle using OpenPose and radiography before or after total knee arthroplasty and assessed the test–retest reliability of each method with intraclass correlation coefficient (1, 1). We evaluated the ability to estimate the radiographic measurement values from the OpenPose values using linear regression analysis and used intraclass correlation coefficients (2, 1) and Bland–Altman analyses to evaluate the agreement and error between OpenPose and radiographic measurements. OpenPose had excellent test–retest reliability (intraclass correlation coefficient (1, 1) = 1.000) and excellent agreement with radiography (intraclass correlation coefficient (2, 1) = 0.915), with regression analysis indicating a large correlation (R2 = 0.865). OpenPose also had a 1.1° fixed error and no systematic error when compared with radiography. This is the first study to validate the use of OpenPose for the estimation of HKA angle in patients with knee osteoarthritis. OpenPose is a reliable and valid tool for measuring HKA angle in patients with knee osteoarthritis. OpenPose, which enables non-invasive and simple measurements, may be a useful tool to assess changes in HKA angle and monitor the progression and post-operative course of knee osteoarthritis. Furthermore, this validated tool can be used not only in clinics and hospitals, but also at home and in training gyms; thus, its use could potentially be expanded to include self-assessment/monitoring.

9 October 2019 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
KFKenji Fujita
Kenji Fujita
TKTamon Kabata
Tamon Kabata
YKYoshitomo Kajino
Yoshitomo Kajino
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya

25 October 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
TKTamon Kabata
Tamon Kabata
TMToru Maeda
Toru Maeda
YKYoshitomo Kajino
Yoshitomo Kajino
KHKazuhiro Hasegawa
Kazuhiro Hasegawa
DIDaisuke Inoue
Daisuke Inoue
HTHiroyuki Tsuchiya
Hiroyuki Tsuchiya
We developed a new povidone iodine coating technology for titanium hip implants and performed a clinical trial to assess its usefulness in suppressing postoperative infection. Results indicate that iodine-supported titanium has favorable antibacterial activity, biocompatibility, and no cytotoxicity. Thirty joints in 28 patients were treated using iodine-supported implants. Fourteen joints were revision total hip arthroplasty (THA) after periprosthetic infection, 13 were primary THA for immunosuppressive conditions or pyogenic arthritis, and 3 were conversions from hemiarthroplasty to THA for immunosuppressive conditions. Two examinations were conducted sequentially until final follow-up: white blood cell (WBC) and C-reactive protein (CRP) were measured pre- and postoperatively and thyroid hormone levels in the blood were examined. The mean follow-up period was 33 months (14–78). There were no signs of infection in any patient at the last follow-up. WBC and CRP levels returned to normal within several weeks. No abnormalities of thyroid gland function were detected. Loosening of the implants did not occur in any patient. Excellent bone ingrowth and ongrowth were found around prostheses. No cytotoxicity or adverse effects were detected. These results suggest that iodine-supported THA implants can be highly effective in preventing and treating postoperative infections.