Recently, the wireless sensor network has been widely deployed for medical care purpose. We have developed a wireless sensor network that can monitor the patients' pulse status for triage purpose, so that a medical team can monitor remotely the health condition of patient and they can treat the patient based on severity of patients' health condition. We developed an electronic triage operating as a sensor node (SN) tagged in patient's arm. The SN consists of microcontroller ATmega328P, ZigBee and pulse sensor to detect patient's pulse. Operating as an electronic triage, the pulse rate from sensor is classified into three categories of severe conditions, i.e., major, minor, and normal status by the microcontroller in SN and sent to the coordinator node (CN) through ZigBee interface. Our system can be deployed in emergency room, triage room, pre/post-op surgery in hospital as well as in disaster area. This paper aims to evaluate the performance of the ZigBee-based wireless sensor network that we developed. We evaluate the effective distance between CN and SN to deliver patients' pulse rate via ZigBee as well as the effective number of SNs that can be accommodated by single CN. The experimental results shown that the effective distance between CN and SN to deliver the pulse rate data is less than 30 meters and the maximum number of SNs can be accommodated by a single CN is 3 (three) nodes.
1 April 2020 in TELKOMNIKA (Telecommunication Computing Electronics and Control)
Wireless Sensor Network has grown rapidly, e.g. using the Zigbee RF module and combined with the Raspberry Pi 3, a reason at this research is building a Wireless Sensor Network (WSN). this research discusses how sensor nodes work well and how Quality of Service (QoS) from the Sensor node being analyzed and the role of Raspberry Pi 3 as an internet gateway will sending a blood pressure data to the database and displayed in real-time on the internet, from this research it is expected that patients can check the blood pressure from home and don’t need to the Hospital even data can be quickly and accurately received by Hospital Officers, doctors, and medical personnel. the purpose of this research is make a prototype to providing a blood pressure (mmHg) real-time data from systolic and diastolic data patient’s that determine patients suffering from symptoms of certain diseases, i.e, anemia, symptoms of hypertension and even more chronic diseases. this research discusses how sensor nodes work well and how Quality of Service (QoS) from the Sensor node being analyzed and the role of Raspberry Pi 3 as an internet gateway will sending a blood pressure data to the database and displayed in real-time on the internet. Furthermore, Zigbee has the task of sending Blood pressure (mmHg) data in real-time to the database and then sent to the internet from Zigbee end-device communication to ZigBee coordinator. Zigbee communication at a distance of 5 meters, RSSI simulations show a value of -29 dBm and the experiment shows a value of -40 dBm, at a distance of 100 m, RSSI shows a value of -55 dBm (simulation) and -86 dBm (experiment).
The Purpose of this research is to determine the Quality of Service (QoS) Zigbee or IEEE 802.15.4 sensor Node use the indicators, i.e. the Receiver Signal Strength and PathLoss (attenuation (-dB)) at the time of communication of the sensor node end device to the sensor Router node or Coordinator sensor node (sink). The factor power consumption sensor node is important to maintain the lifetime sensor node, The Sensor data in this research is the pulse sensor. The development of the Wireless Sensor Network communication system is in multi-hop communication, with efforts to obtain low power consumption on each sensor node. This study utilizes the Routing Protocol for Low Power and Lossy Network (RPL) method with position management on the sensor node on DODAGs consequently, that the average power consumption value for each sensor node is low. The benefit of the Sensor node is to send pulse sensor data from various nodes that are interconnected at different distances in multi-hop so that power consumption and Quality of Services (QoS) can be identified from the sensor node. From the research results, the average PathLoss value of IEEE 802.15.4 or Zigbee in free space is obtained by comparing the various simulation values and field experiments at a distance of 50 m at -75.4 dB and the Average Receiver Signal Strength (RSS) with a comparison of Equation and Experiments in the field with parameters The minimum Power Transmitter is 0 dBm and the Power Transmitter is maximum +20 dBm at a distance of 50m at - 66.6 dBm. Therefore, Pulse Sensor data will be displayed on the Web Page and stored in the MySQL database using Raspberry PI 3 as the Internet Gateway.