Hüsniye Yıldırım

Dr. Hüsniye Yıldırım

Nuh Naci Yazgan University, Kayseri, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
AKAyşegül Köroğlu
Ayşegül Köroğlu
OŞOnur Şahin
Onur Şahin
AKAhmet Serkan Küçükekenci
Ahmet Serkan Küçükekenci
DDDogu Dede
Dogu Dede
HYHüsniye Yıldırım
Hüsniye Yıldırım
BYBurak Yilmaz
Burak Yilmaz
The surface properties and color stability of interim crown materials may vary depending on the toothbrushing procedure. This study aimed to investigate the effects of toothbrushing and different toothpastes on the surface roughness (Ra) and color stability of different interim crown materials. Disc-shaped specimens were prepared from four interim crown materials (Tab 2000 (ChPM), Imident (LaPM), Protemp 4 (ChDM), and Telio-CAD (CadPM)). Specimens were divided into four subgroups for the control group (Cnt) and for simulated toothbrushing with distilled water (Dw) or with two different toothpastes (whitening toothpaste (WTp), activated charcoal toothpaste (ACTp)). The specimens’ Ra values were measured before and after 10,000 cycles of toothbrushing. The color parameters were measured and the color differences (ΔE00) were calculated. Data were statistically analyzed by two-way analysis of variance (ANOVA) and Tukey’s HSD tests. A significant increase in the Ra values was observed after toothbrushing, except for the LaPM_Dw, ChDM_Dw, and all the CadPM specimens (p < 0.05). Toothbrushing with toothpastes increased the ΔE00 values of all ChPM and ChDM interim materials (p < 0.05). Before and after all toothbrushing procedures, the CadPM specimens had smoother and ChPM specimens had rougher surfaces than the other interim materials. The two tested toothpastes had similar effects on the Ra of all interim materials. Non-perceivable color changes were seen only with the CadPM_Dw group.

25 November 2025 in Coatings
Verified
Journal Article
Open access
PDF file
OŞOnur Şahin
Onur Şahin
AKAyşegül Köroğlu
Ayşegül Köroğlu
DDDogu Dede
Dogu Dede
HYHüsniye Yıldırım
Hüsniye Yıldırım
ÜYÜnsun Yağcı
Ünsun Yağcı
SESelda Gökçe Erdal
Selda Gökçe Erdal
The clinical performance of interim restorations, particularly in the anterior region, largely depends on surface roughness (Ra) and color stability. This study investigated the influence of different toothbrushing durations on the surface roughness and color stability of CAD/CAM interim restorative materials subjected to varying polishing protocols. A total of 140 rectangular specimens (15 × 9 × 2 mm) were fabricated from highly cross-linked PMMA blocks (Telio-CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and allocated to two surface treatment groups: conventional polishing and surface coating with Optiglaze Color (GC Corp, Tokyo, Japan). Each group was further divided into seven subgroups (n = 10), including a control (no brushing) and groups that performed simulated brushing (DentArge TB-6.1, Analitik Medikal, Gaziantep, Turkiye) with distilled water or toothpaste (Colgate Total; Colgate-Palmolive, New York, NY, USA), for 2 weeks, 3 months, or 1 year. Ra values were recorded before (Ra0) and after brushing (Ra1), and color changes (ΔE00) following immersion in coffee solution were calculated. Statistical analysis was performed using a three-way ANOVA and Tukey’s HSD test (α = 0.05). Specimens coated with Optiglaze Color exhibited significantly lower Ra values compared with conventionally polished specimens (p < 0.05). The Con_Tp_1Yr group demonstrated the highest Ra value (0.53 ± 0.08 µm) compared to all other specimen groups (p < 0.05). A one-year brushing duration markedly increased ΔE00 values in both surface treatment groups regardless of brushing medium (p < 0.05). While surface coating was more effective than conventional polishing in obtaining smoother surfaces at all brushing durations, prolonged brushing with toothpaste produced a progressive increase in surface roughness in both treatments. Ra values increased consistently over time, with the most pronounced changes observed after one year of brushing. Within the limitations of using a single CAD/CAM material, it may be concluded that surface coating improves the initial smoothness of interim crowns; however, extended brushing and different brushing media can intensify color changes, indicating that the long-term stability of surface-coated interim restorations may be compromised under abrasive conditions.

8 March 2021 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
ATAyça Tulga
Ayça Tulga
HYHüsniye Yıldırım
Hüsniye Yıldırım
The present study evaluated the effects of cleaning methods on resin bond strength to contaminated monolithic zirconia. A total of 180 bar-shaped monolithic zirconia specimens (12 mm × 4 mm × 1.2 mm) were abraded with aluminum oxide and divided into nine groups (n = 10). The control group (Cnt) comprised non-contaminated or cleaned monolithic zirconia specimens. Half of the remaining samples were contaminated with saliva (S) and the other half with a silicone disclosing agent (F; Fit checker). The bonding surfaces of the specimens were cleaned with water (Sw and Fw), 0.5% sodium hypochlorite (NaOCl) solution (Sh and Fh), 37% phosphoric acid gel (Sa and Fa), or plasma treatment (Sp and Fp). The bars were luted end-to-end on the bonding surfaces using a self-adhesive resin cement with a custom-made stainless-steel mold. After 72 h of water storage, the bond strength was measured using a four-point bending test. Data were analyzed using two-way ANOVA and Tukey’s test. The Cnt group showed the highest four-point bending strength (p < .05). There were no significant differences among the groups subjected to the cleaning methods, except the NaOCl groups (p > .05). These findings indicate that the cleaning protocol for saliva- or fit checker-contaminated monolithic zirconia ceramics must be taken into account to ensure zirconia–resin cement bond strength resistance. The plasma treatment that an alternative cleaning method for decontamination did not affect the bond strength between monolithic zirconia and resin cement.