Hugo Knobel

Mr. Hugo Knobel

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
POPouline Van Oort
Pouline Van Oort
SBSanne De Bruin
Sanne De Bruin
HWHans Weda
Hans Weda
HKHugo Knobel
Hugo Knobel
MSMarcus J. Schultz
Marcus J. Schultz
OCOn Behalf of the MARS Consortium
On Behalf of the MARS Consortium
The diagnosis of hospital-acquired pneumonia remains challenging. We hypothesized that analysis of volatile organic compounds (VOCs) in exhaled breath could be used to diagnose pneumonia or the presence of pathogens in the respiratory tract in intubated and mechanically-ventilated intensive care unit patients. In this prospective, single-centre, cross-sectional cohort study breath from mechanically ventilated patients was analysed using gas chromatography-mass spectrometry. Potentially relevant VOCs were selected with a p-value < 0.05 and an area under the receiver operating characteristics curve (AUROC) above 0.7. These VOCs were used for principal component analysis and partial least square discriminant analysis (PLS-DA). AUROC was used as a measure of accuracy. Ninety-three patients were included in the study. Twelve of 145 identified VOCs were significantly altered in patients with pneumonia compared to controls. In colonized patients, 52 VOCs were significantly different. Partial least square discriminant analysis classified patients with modest accuracy (AUROC: 0.73 (95% confidence interval (CI): 0.57–0.88) after leave-one-out cross-validation). For determining the colonization status of patients, the model had an AUROC of 0.69 (95% CI: 0.57–0.82) after leave-one-out cross-validation. To conclude, exhaled breath analysis can be used to discriminate pneumonia from controls with a modest to good accuracy. Furthermore breath profiling could be used to predict the presence and absence of pathogens in the respiratory tract. These findings need to be validated externally.

7 October 2019 in COPD: Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PVP. van Velzen
P. van Velzen
PBPaul Brinkman
Paul Brinkman
HKHugo Knobel
Hugo Knobel
JBJ. W. K. van Den Berg
J. W. K. van Den Berg
RJR. E. Jonkers
R. E. Jonkers
PSP.J. Sterk
P.J. Sterk
Many patients with chronic obstructive lung disease (COPD) experience exacerbations. The diagnosis of an exacerbation is solely based on symptoms. We hypothesized that exhaled breath profiles, measured by Gas Chromatography-Mass Spectrometry (GC-MS) or electronic nose (eNose), are different between stable disease and exacerbations and may have the potential to serve as biomarkers for COPD exacerbations. In this prospective follow-up study, breath samples were taken during stable COPD, during a subsequent exacerbation and after recovery. Samples were analyzed by GC-MS and eNose. CCQ symptom scores were associated with univariate outcomes of GC-MS and eNose using analysis of covariance (ANCOVA). After multivariate modeling by Principal Component Analysis (PCA), paired student t-tests were performed. Sixty-eight patients were included, 31 had an exacerbation and 16 patients had breath sampled at all three time points. Significant differences were found in breathprints taken during exacerbation as compared to baseline and recovery for both GC-MS and eNose. Breath profiles obtained by GC-MS as well as by eNose showed a correct classification of 71% (10/14) for baseline vs exacerbation and of 78% (11/14) for exacerbation vs recovery. These results provide proof of principle that exhaled breath can serve as a noninvasive biomarker for the diagnosis of COPD exacerbations.

31 October 2022 in Clinical Infectious Diseases
Verified
Journal Article
Open access
PDF file
WAWaqar Ahmed
Waqar Ahmed
DFDominic Fenn
Dominic Fenn
IWIain R White
Iain R White
BDBreanna Dixon
Breanna Dixon
TNTamara M E Nijsen
Tamara M E Nijsen
SFStephen J Fowler
Stephen J Fowler
Early and accurate recognition of respiratory pathogens is crucial to prevent increased risk of mortality in critically ill patients. Microbial-derived volatile organic compounds (mVOCs) in exhaled breath could be used as noninvasive biomarkers of infection to support clinical diagnosis. In this study, we investigated the diagnostic potential of in vitro–confirmed mVOCs in the exhaled breath of patients under mechanical ventilation from the BreathDx study. Samples were analyzed by thermal desorption–gas chromatography–mass spectrometry. Pathogens from bronchoalveolar lavage (BAL) cultures were identified in 45 of 89 patients and Staphylococcus aureus was the most commonly identified pathogen (n = 15). Of 19 mVOCs detected in the in vitro culture headspace of 4 common respiratory pathogens (S. aureus, Pseudomonas aeruginosa, Klebsiella pneumoniae, and Escherichia coli), 14 were found in exhaled breath samples. Higher concentrations of 2 mVOCs were found in the exhaled breath of patients infected with S. aureus compared to those without (3-methylbutanal: P < .01, area under the receiver operating characteristic curve [AUROC] = 0.81–0.87; and 3-methylbutanoic acid: P = .01, AUROC = 0.79–0.80). In addition, bacteria identified from BAL cultures that are known to metabolize tryptophan (E. coli, Klebsiella oxytoca, and Haemophilus influenzae) were grouped and found to produce higher concentrations of indole compared to breath samples with culture-negative (P = .034) and other pathogen-positive (P = .049) samples. This study demonstrates the capability of using mVOCs to detect the presence of specific pathogen groups with potential to support clinical diagnosis. Although not all mVOCs were found in patient samples within this small pilot study, further targeted and qualitative investigation is warranted using multicenter clinical studies.

1 January 2014 in Respiratory Physiology & Neurobiology
Verified
Journal Article
Closed access
LBLieuwe Bos
Lieuwe Bos
YWYuanyue Wang
Yuanyue Wang
HWHans Weda
Hans Weda
TNTamara M Nijsen
Tamara M Nijsen
AJAnton P.G.E. Janssen
Anton P.G.E. Janssen
PSPeter J. Sterk
Peter J. Sterk

30 October 2018 in Journal of Breath Research
Verified
Journal Article
Open access
PDF file
WAWaqar Ahmed
Waqar Ahmed
PBPaul Brinkman
Paul Brinkman
HWHans Weda
Hans Weda
HKHugo Knobel
Hugo Knobel
YXYun Xu
Yun Xu
SFStephen J Fowler
Stephen J Fowler
Methods for breath sampling and analysis require robust quality assessment to minimise the risk of false discoveries. Planning large-scale multi-site breath metabolite profiling studies also requires careful consideration of systematic and random variation as a result of sampling and analysis techniques. In this study we use breath sample data from the recent U-BIOPRED cohort to evaluate and discuss some important methodological considerations such as batch variation and correction, variation between sites, storage and transportation, as well as inter-instrument analytical differences. Based on this we provide a summary of recommended best practices for new large scale multi-site studies.

30 January 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
TSThomas Schenkel
Thomas Schenkel
ASA. M. Snijders
A. M. Snijders
KNK. Nakamura
K. Nakamura
PSP. A. Seidl
P. A. Seidl
BMB. Mak
B. Mak
EEE. Esarey
E. Esarey
Nanostructured surfaces enhance ion yields in matrix-assisted laser desorption–ionization mass spectrometry (MALDI-MS). The spike protein complex, S1, is one fingerprint signature of Sars-CoV-2 with a mass of 75 kDa. Here, we show that MALDI-MS yields of Sars-CoV-2 spike protein ions in the 100 kDa range are enhanced 50-fold when the matrix–analyte solution is placed on substrates that are coated with a dense forest of multi-walled carbon nanotubes, compared to yields from uncoated substrates. Nanostructured substrates can support the development of mass spectrometry techniques for sensitive pathogen detection and environmental monitoring.