Impact of dust concentration and weather conditions – wind speed and relative humidity – on power generation of photovoltaic (PV) panels investigated experimentally in Tehran, Iran, for the period of April 10–September 22, 2018. Two Photovoltaic panels together with data-logging equipment were applied in this experiment. One panel was cleaned every day, while the other was remained unclean after 45 days. A performance ratio called “cleanness index” (CI) which is a temperature-corrected performance ratio of a soiled PV panel to that of a clean one was also used to indicate the dust deposition effect on PV panel performance. The uncertainty range of experimental results was between 5.27% and 5.55%. The results show that cleanness index had positive correlation with wind speed and negative correlations with relative humidity and dust concentration. Thus, in comparison to the clean PV panel, the output-power of the soiled panel reduced, approximately 8–12% per month. Furthermore, in order to numerically predict daily change of cleanness index (ΔCIPre), a linear regression model was developed and the outcome revealed that dust concentration had the most impact, with 21.56%.
28 July 2021 in Environmental Science and Pollution Research
The purpose of this experimental study is to measure the drag and heat transfer coefficients of the non-circular tubes including square, elliptic, and cam-shape tubes in a turbulent air cross flow. Studies have been made at 0° to 180° angles of attack ( ) and Reynolds numbers (Re) based on the equivalent diameter of a circular tube within the range of 1.4 × 104 < Reeq < 7.5 × 104. The equivalent diameter Deq = 46 mm was chosen for the tubes. The results show that the minimum and maximum drag coefficients (Cd) belong to the cam-shape and square tubes at 0°, respectively. The (Cd) of the cam-shape and square tubes are 60% less and 25% more than the equivalent circular tube, respectively. Also, the ratio of the average Nusselt number ( ) to the drag coefficient, /Cd, was used to compare non-circular tubes and with their equivalent circular ones. The results show that the maximum value belongs to the cam tube and the minimum occurs for the square tube at α = 0°. The /Cd ratio of the cam tube is 128% more than the equivalent circular tube, while the square tube yields a /Cd ratio that is13% less than its circular equivalent.
4 May 2022 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Solar stills are known as one of the best and most efficient methods for water desalination. Due to low production of solar stills, researchers have been using experimental and theoretical methods to come up with possible solutions for ameliorating freshwater production through these systems. This study aims to investigate the performance of a single slope solar still combined with a v-grooved solar air heater. Important parameters (height of the v-grooves, length of the collector, and air mass flow) affecting the performance of the proposed system were mathematically investigated using MATLAB software. The average deviation between the experimental and theoretical results was found to be about 7%. Furthermore, the results showed that the water production rate and the efficiency of the modified solar still were 150% and 44.20% higher than those of the conventional ones, respectively. Two new correlations were proposed based on the experimental results in order to predict the water production via solar stills, which are in good agreement with the results of the existing models. Based on the obtained results, the increase in the inlet air mass flow rate was not conducive to water production as the production rate was reduced by 60%. In addition, through the economic analysis, the cost per liter for the modified still was determined to be 0.03 [ ] with an interest rate of 10%.