Zhanhong Wei

Dr. Zhanhong Wei

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2020 in IEEE Access
Verified
Journal Article
Open access
ZWZhanhong Wei
Zhanhong Wei
WFWanliang Fang
Wanliang Fang
Jun LiuJun Liu
Jun Liu
To mitigate commutation failures (CFs) and minimize the instability of HVDC systems due to AC faults or control mode ambiguity, a constant extinction voltage-time area based control strategy with virtual resistance is proposed. In this strategy, using sine-cosine components detector and considering zero-crossing phase shift of commutation voltage, the extinction angle setting value can be adjusted dynamically. Meanwhile, to reflect the characteristics of DC current during the fault and recovery process, a virtual resistance is introduced into the control system and DC voltage considering the voltage drop of the virtual resistance is taken as the input of voltage-dependent current order limiter (VDCOL). Through theoretical analysis, the proposed strategy not only reduces the firing angle dynamically, but also reduces DC current by lowering the current order on the rectifier side immediately when the AC voltage disturbance is detected, thereby further reducing the occurrence of CFs. Therefore, the control strategy can effectively suppress successive and intermittent CFs. The effectiveness of the proposed control strategy is verified by simulation of the single HVDC and multi-infeed HVDC model based on the CIGRE HVDC benchmark system, in which AC-DC current criterion of identifying CF and suppression ratio index are adopted. The simulation results show that the proposed control strategy can effectively mitigate CFs under single-phase and three-phase faults to a certain extent. Comparing with the existing control strategies based on controller modification, i.e. commutation failure prevention, DC current predictive control, smooth logic switching control and DC current limitation control strategy based on virtual resistance, the proposed control strategy is superior in mitigation effects. The average suppression rates of these strategies are 1.66%, 3.21%, 6.11%, 3.35%, and 8.33% under single-phase fault, respectively; with the rates of 1.4%, 2.72%, 4.97%, 0%, and 6.8% under three-phase fault, respectively.

8 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
MXMin Xu
Min Xu
WLWanwei Li
Wanwei Li
ZFZhihui Feng
Zhihui Feng
WBWangwang Bai
Wangwang Bai
LJLingling Jia
Lingling Jia
ZWZhanhong Wei
Zhanhong Wei
To solve the problem regarding the large-scale grid-connected consumption of a high proportion of new energy sources, a concentrating solar power (CSP)-photovoltaic (PV)-wind power day-ahead and intraday-coordinated optimal dispatching method considering source load uncertainty is proposed. First, the uncertainty of day-ahead wind power output prediction is described by the multi-scenario stochastic planning method, and the uncertainty of intraday source-load is characterized by the trapezoidal fuzzy number equivalence model. Second, based on the combined scenario set of day-ahead wind power output prediction, the day-ahead optimal dispatch is performed by combining thermal and CSP plants, and the day-ahead thermal and CSP plant dispatch output and intraday source load fuzzy dataset are used as the input quantities for the day-ahead dispatch. Thus, the scheduling output and rotating backup plan for thermal power and CSP plants were determined; finally, the validity and feasibility of the model were verified using arithmetic examples.

1 July 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
ZWZhanhong Wei
Zhanhong Wei
WFWanliang Fang
Wanliang Fang
Jun LiuJun Liu
Jun Liu

1 July 2023 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
WCWei Chen
Wei Chen
HLHaonan Lu
Haonan Lu
ZWZhanhong Wei
Zhanhong Wei
To promote the efficient use of energy storage and renewable energy consumption in the integrated energy system (IES), an economic dispatch strategy for the concentrating solar power (CSP)-IES with generalized energy storage and a conditional value-at-risk (CVaR) model is proposed. First, considering the characteristics of energy storage and distributed power supply timing, a CSP-IES configuration is established by using a CSP plant to achieve thermal decoupling of the combined heat and power unit and by defining the thermal storage system of the CSP plant and the battery as the actual energy storage. Second, the fuzzy response of the logistic function is used to optimize the time-of-use tariff to guide load shifting, and the load shifting is defined as virtual energy storage. Third, the CSP-IES economic dispatch model is established to consider the carbon emission allowance model. Finally, considering the system uncertainty, a fuzzy chance constraint is used to relax the system power balance constraint, and then the trapezoidal fuzzy number is transformed into a deterministic equivalence class, and the CVaR model is used as a risk assessment index to quantify the risk cost of the system due to uncertainty. The CSP-IES economic dispatch model with CVaR is constructed. The feasibility and effectiveness of the proposed optimization model are verified by comparing various scenarios.

1 March 2024 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
WCWei Chen
Wei Chen
HLHaonan Lu
Haonan Lu
ZWZhanhong Wei
Zhanhong Wei
To further promote the efficient use of energy storage and the local consumption of renewable energy in a multi-integrated energy system (MIES), a MIES model is developed based on the operational characteristics and profitability mechanism of a shared energy storage station (SESS), considering concentrating solar power (CSP), integrated demand response, and renewable energy output uncertainty. We propose a corresponding MIES model based on co-operative game theory and the CSP and an optimal allocation method for MIES shared energy storage. The model considers the maximum operating benefit of the SESS as the upper objective function and the minimum operating cost of the MIES as the lower objective function. First, the Karush–Kuhn–Tucker conditions of the lower-layer model are transformed into constraints of the upper-layer model, and the Big-M method is used to linearize the nonlinear problem and convert the two-layer nonlinear model into a single-layer linear model. Second, based on the Nash negotiation theory, the benefits of each IES in the MIES are allocated. Finally, the fuzzy chance constraints are used to relax the power balance constraints, and the trapezoidal fuzzy numbers are transformed into a deterministic equivalence class to assess the impact of renewable energy output uncertainty on system operation. The validity and rationality of the proposed two-layer model are verified through simulation, and the results demonstrate that the proposed shared storage capacity leasing model can effectively reduce the total operation cost, increase the profitability of the shared storage operator, and increase the utilization rate of the SESS.

23 July 2026 in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
Verified
Journal Article
Closed access
PDF file
JLJie Lin
Jie Lin
YLYulong Luo
Yulong Luo
ZWZhanhong Wei
Zhanhong Wei
JLJiangtao Li
Jiangtao Li
WCWei Chen
Wei Chen
Introduction/Objective: Chaotic oscillations induced by DC-link (Direct current) capacitor voltage fluctuations pose a critical threat to the stability of grid-connected permanent magnet synchronous generators (PMSGs) in wind power systems. Such nonlinear instabilities can degrade power quality and, if left unaddressed, lead to cascading failures. This study aims to develop a refined nonlinear model of the DC-link capacitor to investigate the Hopf bifurcation mechanism and the subsequent transition to chaos. Precise stability boundaries are derived, and the underlying chain of instability is elucidated. Methods: A fourth-order nonlinear model incorporating DC-link capacitor dynamics is developed, extending conventional third-order representations. The critical conditions for Hopf bifurcation are derived using the Routh–Hurwitz criterion and eigenvalue analysis of the Jacobian matrix. The onset of chaos is validated through numerical simulations, complemented by the computation of Lyapunov exponent spectra and power spectral density analysis. Results: Two critical thresholds for the voltage modulation parameter are identified at U = 7.85 and U = 16.5. Beyond these thresholds, the system undergoes Hopf bifurcation and subsequently enters chaotic regimes, as evidenced by a positive maximum Lyapunov exponent and a continuous broadband power spectrum. A chain-instability mechanism is revealed: "voltage imbalance - torque oscillation - speed instability". Discussion: These results reveal that DC-link voltage fluctuations are the primary driver of Hopf bifurcation and subsequent chaos in grid-connected PMSGs. The identified stability thresholds and chain-instability pathway provide a clear theoretical basis for converter parameter design. Furthermore, the chaotic nature implies that effective suppression strategies should prioritize active regulation of DC-link dynamics over conventional speed-loop damping alone. Conclusion: The study provides a theoretical criterion for stability and clarifies the dynamic coupling mechanism driven by DC-link parameters. These findings provide direct guidance on converter design, parameter tuning, and chaos suppression for practical PMSG-based wind energy systems.