Jeremy D Brown

Dr. Jeremy D Brown

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
JBJeremy D Brown
Jeremy D Brown
COConor E. O'BRien
Conor E. O'BRien
SLSarah C. Leung
Sarah C. Leung
KDKristoffel R. Dumon
Kristoffel R. Dumon
DLDavid I. Lee
David I. Lee
KKKatherine J. Kuchenbecker
Katherine J. Kuchenbecker
Objective: Most trainees begin learning robotic minimally invasive surgery by performing inanimate practice tasks with clinical robots such as the Intuitive Surgical da Vinci. Expert surgeons are commonly asked to evaluate these performances using standardized five-point rating scales, but doing such ratings is time consuming, tedious, and somewhat subjective. This paper presents an automatic skill evaluation system that analyzes only the contact force with the task materials, the broad-bandwidth accelerations of the robotic instruments and camera, and the task completion time. Methods: We recruited $N = 38$ participants of varying skill in robotic surgery to perform three trials of peg transfer with a da Vinci Standard robot instrumented with our Smart Task Board. After calibration, three individuals rated these trials on five domains of the Global Evaluative Assessment of Robotic Skill (GEARS) structured assessment tool, providing ground-truth labels for regression and classification machine learning algorithms that predict GEARS scores based on the recorded force, acceleration, and time signals. Results: Both machine learning approaches produced scores on the reserved testing sets that were in good to excellent agreement with the human raters, even when the force information was not considered. Furthermore, regression predicted GEARS scores more accurately and efficiently than classification. Conclusion: A surgeon's skill at robotic peg transfer can be reliably rated via regression using features gathered from force, acceleration, and time sensors external to the robot. Significance: We expect improved trainee learning as a result of providing these automatic skill ratings during inanimate task practice on a surgical robot.

25 November 2015 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
JBJeremy D Brown
Jeremy D Brown
APAndrew Paek
Andrew Paek
MSMashaal Syed
Mashaal Syed
MOMarcia K. O’mAlley
Marcia K. O’mAlley
PSPatricia A. Shewokis
Patricia A. Shewokis
BGBrent` Gillespie
Brent` Gillespie
Haptic display technologies are well suited to relay proprioceptive, force, and contact cues from a prosthetic terminal device back to the residual limb and thereby reduce reliance on visual feedback. The ease with which an amputee interprets these haptic cues, however, likely depends on whether their dynamic signal behavior corresponds to expected behaviors—behaviors consonant with a natural limb coupled to the environment. A highly geared motor in a terminal device along with the associated high back-drive impedance influences dynamic interactions with the environment, creating effects not encountered with a natural limb. Here we explore grasp and lift performance with a backdrivable (low backdrive impedance) terminal device placed under proportional myoelectric position control that features referred haptic feedback. We fabricated a back-drivable terminal device that could be used by amputees and non-amputees alike and drove aperture (or grip force, when a stiff object was in its grasp) in proportion to a myoelectric signal drawn from a single muscle site in the forearm. In randomly ordered trials, we assessed the performance of N=10 participants (7 non-amputee, 3 amputee) attempting to grasp and lift an object using the terminal device under three feedback conditions (no feedback, vibrotactile feedback, and joint torque feedback), and two object weights that were indiscernible by vision. Both non-amputee and amputee participants scaled their grip force according to the object weight. Our results showed only minor differences in grip force, grip/load force coordination, and slip as a function of sensory feedback condition, though the grip force at the point of lift-off for the heavier object was significantly greater for amputee participants in the presence of joint torque feedback. An examination of grip/load force phase plots revealed that our amputee participants used larger safety margins and demonstrated less coordination than our non-amputee participants. Our results suggest that a backdrivable terminal device may hold advantages over non-backdrivable devices by allowing grip/load force coordination consistent with behaviors observed in the natural limb. Likewise, the inconclusive effect of referred haptic feedback on grasp and lift performance suggests the need for additional testing that includes adequate training for participants.

11 June 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
NTNeha Thomas
Neha Thomas
GUGarrett Ung
Garrett Ung
CMColette McGarvey
Colette McGarvey
JBJeremy D Brown
Jeremy D Brown
Despite the technological advancements in myoelectric prostheses, body-powered prostheses remain a popular choice for amputees, in part due to the natural sensory advantage they provide. Research on haptic feedback in myoelectric prostheses has delivered mixed results. Furthermore, there is limited research comparing various haptic feedback modalities in myoelectric prostheses. In this paper, we present a comparison of the feedback intrinsically present in body-powered prostheses (joint-torque feedback) to a commonly proposed feedback modality for myoelectric prostheses (vibrotactile feedback). In so doing, we seek to understand whether the advantages of kinesthetic feedback present in body-powered prostheses translate to myoelectric prostheses, and whether there are differences between kinesthetic and cutaneous feedback in prosthetic applications. We developed an experimental testbed that features a cable-driven, voluntary-closing 1-DoF prosthesis, a capstan-driven elbow exoskeleton, and a vibrotactile actuation unit. The system can present grip force to users as either a flexion moment about the elbow or vibration on the wrist. To provide an equal comparison of joint-torque and vibrotactile feedback, a stimulus intensity matching scheme was utilized. Non-amputee participants (n=12) were asked to discriminate objects of varying stiffness with the prosthesis in three conditions: no haptic feedback, vibrotactile feedback, and joint-torque feedback. Results indicate that haptic feedback increased discrimination accuracy over no haptic feedback, but the difference between joint-torque feedback and vibrotactile feedback was not significant. In addition, our results highlight nuanced differences in performance depending on the objects’ stiffness, and suggest that participants likely pay less attention to incidental cues with the addition of haptic feedback. Even when haptic feedback is not modality matched to the task, such as in the case of vibrotactile feedback, performance with a myoelectric prosthesis can improve significantly. This implies it is possible to achieve the same benefits with vibrotactile feedback, which is cheaper and easier to implement than other forms of feedback.

1 April 2013
Verified
Conference Paper
Closed access
JBJeremy D Brown
Jeremy D Brown
APAndrew Paek
Andrew Paek
MSMashaal Syed
Mashaal Syed
MOMarcia K. O'Malley
Marcia K. O'Malley
PSPatricia A. Shewokis
Patricia A. Shewokis
BGBrent` Gillespie
Brent` Gillespie
Achieving dexterous volitional control of an upper-limb prosthetic device will require multimodal sensory feedback that goes beyond vision. Haptic display is well-positioned to provide this additional sensory information. Haptic display, however, includes a diverse set of modalities that encode information differently. We have begun to make a comparison between two of these modalities, force feedback spanning the elbow, and amplitude-modulated vibrotactile feedback, based on performance in a functional grasp and lift task. In randomly ordered trials, we assessed the performance of N=11 participants (8 able-bodied, 3 amputee) attempting to grasp and lift an object using an EMG controlled gripper under three feedback conditions (no feedback, vibrotactile feedback, and force feed-back), and two object weights that were undetectable by vision. Preliminary results indicate differences between able-bodied and amputee participants in coordination of grasp and lift forces. In addition, both force feedback and vibrotactile feedback contribute to significantly better task performance (fewer slips) and better adaptation following an unpredicted weight change. This suggests that the development and utilization of internal models for predictive control is more intuitive in the presence of haptic feedback.

14 April 2016 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
JBJeremy D Brown
Jeremy D Brown
TKTimothy S. Kunz
Timothy S. Kunz
DGDuane Gardner
Duane Gardner
MSMackenzie K. Shelley
Mackenzie K. Shelley
ADAlicia J. Davis
Alicia J. Davis
RGR. Brent Gillespie
R. Brent Gillespie
Myoelectric prostheses have many advantages over body-powered prostheses, yet the absence of sensory feedback in myoelectric devices is one reason body-powered devices are often preferred by amputees. While considerable progress has been made in the mechanical design and control of myoelectric prostheses, research on haptic feedback has not had a similar impact. In this study, we seek to develop a fundamental understanding of the utility of force feedback and vision in the functional operation of a body-powered upper-limb prosthesis. Using a custom body-powered prosthesis in which force feedback can be conditionally removed, we asked N = 10 non-amputee participants to identify objects based on stiffness in four separate conditions with and without visual and/or force feedback. Results indicate that the combination of visual and force feedback allows for the best accuracy, followed by force feedback only, then visual feedback only. In addition, combining force feedback with visual feedback does not significantly affect identification timing compared to visual feedback alone. These findings suggest that consideration should be given to the development of force feedback displays for myoelectric prostheses that function like a Bowden cable, coupling the amputee's control input to the resulting feedback.

28 April 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
GCGuido Caccianiga
Guido Caccianiga
AMAndrea Mariani
Andrea Mariani
EMElena De Momi
Elena De Momi
GCGabriela Cantarero
Gabriela Cantarero
JBJeremy D Brown
Jeremy D Brown