Jennifer Z. Paxton

Dr. Jennifer Z. Paxton

Anatomy@Edinburgh, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Edinburgh EH8 9AB, UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2010 in Tissue Engineering Part A
Verified
Journal Article
Closed access
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
LGLiam M. Grover
Liam M. Grover
KBKeith Baar
Keith Baar
For musculoskeletal tissues that transmit loads during movement, the interfaces between tissues are essential to minimizing injury. Therefore, the reproduction of functional interfaces within engineered musculoskeletal tissues is critical to the successful transfer of the technology to the clinic. The goal of this work was to rapidly engineer ligament equivalents in vitro that contained both the soft tissue sinew and a hard tissue bone mimetic. This goal was achieved using cast brushite (CaHPO4·2H2O) anchors to mimic bone and a fibrin gel embedded with fibroblasts to create the sinew. The constructs formed within 7 days. Fourteen days after seeding, the interface between the brushite and sinew could withstand a stress of 9.51 ± 1.7 kPa before failure and the sinew reached a Young's modulus value of 0.16 ± 0.03 MPa. Treatment with ascorbic acid and proline increased the collagen content of the sinew (from 1.34% ± 0.2% to 8.34% ± 0.37%), strength of the interface (29.24 ± 6 kPa), and modulus of the sinew (2.69 ± 0.25 MPa). Adding transforming growth factor-β resulted in a further increase in collagen (11.25% ± 0.39%), interface strength (42 ± 8 kPa), and sinew modulus (5.46 ± 0.68 MPa). Both scanning electron and Raman microscopy suggested that the interface between the brushite and sinew mimics the in vivo tidemark at the enthesis. This work describes a major step toward the development of tissue-engineered ligaments for the repair of ligament ruptures in humans.

1 June 2009 in Tissue Engineering Part A
Verified
Journal Article
Closed access
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
KDKenneth Donnelly
Kenneth Donnelly
RKRobert P. Keatch
Robert P. Keatch
KBKeith Baar
Keith Baar
Ligaments and tendons have previously been tissue engineered. However, without the bone attachment, implantation of a tissue-engineered ligament would require it to be sutured to the remnant of the injured native tissue. Due to slow repair and remodeling, this would result in a chronically weak tissue that may never return to preinjury function. In contrast, orthopaedic autograft reconstruction of the ligament often uses a bone-to-bone technique for optimal repair. Since bone-to-bone repairs heal better than other methods, implantation of an artificial ligament should also occur from bone-to-bone. The aim of this study was to investigate the use of a poly(ethylene glycol) diacrylate (PEGDA) hydrogel incorporated with hydroxyapatite (HA) and the cell-adhesion peptide RGD (Arg-Gly-Asp) as a material for creating an in vitro tissue interface to engineer intact ligaments (i.e., bone-ligament-bone). Incorporation of HA into PEG hydrogels reduced the swelling ratio but increased mechanical strength and stiffness of the hydrogels. Further, HA addition increased the capacity for cell growth and interface formation. RGD incorporation increased the swelling ratio but decreased mechanical strength and stiffness of the material. Optimum levels of cell attachment were met using a combination of both HA and RGD, but this material had no better mechanical properties than PEG alone. Although adherence of the hydrogels containing HA was achieved, failure occurs at about 4 days with 5% HA. Increasing the proportion of HA improved interface formation; however, with high levels of HA, the PEG HA composite became brittle. This data suggests that HA, by itself or with other materials, might be well suited for engineering the ligament–bone interface.

1 February 2012 in Tissue Engineering Part A
Verified
Journal Article
Closed access
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
PHPaul Hagerty
Paul Hagerty
JAJonathan J. Andrick
Jonathan J. Andrick
KBKeith Baar
Keith Baar
Dynamic mechanical input is believed to play a critical role in the development of functional musculoskeletal tissues. To study this phenomenon, cyclic uniaxial mechanical stretch was applied to engineered ligaments using a custom-built bioreactor and the effects of different stretch frequency, amplitude, and duration were determined. Stretch acutely increased the phosphorylation of p38 (3.5±0.74-fold), S6K1 (3.9±0.19-fold), and ERK1/2 (2.45±0.32-fold). The phosphorylation of ERK1/2 was dependent on time, rather than on frequency or amplitude, within these constructs. ERK1/2 phosphorylation was similar following stretch at frequencies from 0.1 to 1 Hz and amplitudes from 2.5% to 15%, whereas phosphorylation reached maximal levels at 10 min of stretch and returned toward basal within 60 min of stretch. Following a single 10-min bout of cyclic stretch, the cells remained refractory to a second stretch for up to 6 h. Using the phosphorylation of ERK1/2 as a guide, the optimum stretch paradigm was hypothesized to be 10 min of stretch at 2.5% of resting length repeated every 6 h. Consistent with this hypothesis, 7 days of stretch using this optimized intermittent stretch program increased the collagen content of the grafts more than a continuous stretch program (CTL=3.1%±0.44%; CONT=4.8%±0.30%; and INT=5.9%±0.56%). These results suggest that short infrequent bouts of loading are optimal for improving engineered tendon and ligament physiology.

29 May 2009 in Rapid Prototyping Journal
Verified
Journal Article
Closed access
PMP.S. Maher
P.S. Maher
RKR.P. Keatch
R.P. Keatch
KDK. Donnelly
K. Donnelly
RMRuth Mackay
Ruth Mackay
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
Purpose: Hydrogels with low viscosities tend to be difficult to use in constructing tissue engineering (TE) scaffolds used to replace or restore damaged tissue, due to the length of time it takes for final gelation to take place resulting in the scaffolds collapsing due to their mechanical instability. However, recent advances in rapid prototyping have allowed for a new technology called bioplotting to be developed, which aims to circumvent these inherent problems. This paper aims to present details of the process.Design/methodology/approach: The paper demonstrates how by using the bioplotting technique complex 3D geometrical scaffolds with accurate feature sizes and good pore definition can be fabriated for use as biological matrices. PEG gels containing the cell‐adhesive RGD peptide sequence were patterned using this method to produce layers of directional microchannels which have a functionalised bioactive surface. Seeding these gels with C2C12 myoblasts showed that the cells responded to the topographical features and aligned themselves along the direction of the channels.Findings: This process allows plotting of various materials into a media bath containing material of similar rheological properties which can be used to both support the structure as it is dispensed and also to initiate cross‐linking of the hydrogel. By controlling concentrations, viscosity and the temperature of both the plotting material and the plotting media, the speed of the hydrogel gelation can be enhanced whilst it is cross‐linking in the media bath. TE scaffolds have been produced using a variety of materials including poly(ethylene glycol) (PEG), gelatin, alginic acid and agarose at various concentrations and viscosities.Originality/value: This paper describes one of the very few examples of accurate construction of 3D biological microporous matrices using hydrogel material fabricated by the bioplotting technique. This demonstrates that this technique can be used to produce 3D scaffolds which promote tissue regeneration.

13 March 2014 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
YTYanni Tan
Yanni Tan
YLYong Liu
Yong Liu
ZZZhongwei Zhao
Zhongwei Zhao
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
LGLiam M. Grover
Liam M. Grover

30 April 2010 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Jennifer Z. PaxtonJennifer Z. Paxton
Jennifer Z. Paxton
KDKenneth Donnelly
Kenneth Donnelly
RKRobert P. Keatch
Robert P. Keatch
KBKeith Baar
Keith Baar
LGLiam M. Grover
Liam M. Grover
The interfaces between musculoskeletal tissues with contrasting moduli are morphologically and biochemically adapted to allow the transmission of force with minimal injury. Current methods of tissue engineering ligaments and tendons do not include the interface and this may limit the future clinical success of engineered musculoskeletal tissues. This study aimed to use solid brushite cement anchors to engineer intact ligaments from bone-to-bone, creating a functional musculoskeletal interface in vitro. We show here that modifying anchor shape and cement composition can alter both the longevity and the strength of an in vitro model of the bone–ligament interface: with values reaching 23 days and 21.6 kPa, respectively. These results validate the use of brushite bone cement to engineer the bone–ligament interface in vitro and raise the potential for future use in ligament replacement surgery.