A mathematical electromechanical model of the multistage induction coil launcher was established based on the current filament model. According to the model, the armature force is determined by the current of the drive coil and the armature together with the mutual inductance gradient between them. Except that the current waveform of the drive coil is determined by the given electrical parameters, the current waveform induced by the armature and the mutual inductance gradient waveform is determined by the position of the drive coil and armature. Therefore, after simulating and comparing, the acceleration performance and efficiency of the matching situation of drive coil current waveform and the mutual inductance gradient waveform can be obtained under limit conditions, and the following results are concluded: 1) the current pulse time is much longer than the mutual inductance gradient time and 2) the current pulse waveform is much smaller than the mutual inductance gradient waveform. Therefore, the current pulse time shall be consistent with the mutual inductance gradient time to achieve smoother acceleration curve and higher efficiency. According to the above-mentioned principles, the current pulse time and mutual inductance gradient time were calculated quantitatively, and the position of drive coil and armature were considered; thus, the armature trigger formula of the multistage induction coil launcher was given, which would lay a theoretical foundation for the performance optimization of the multistage induction coil launcher.
The influence of electromagnetic induction coil launcher (EICL) system parameters on the launch performance was analyzed, and a method for measuring the launch performance of an EICL system with a muzzle velocity and energy conversion efficiency was proposed. The EICL system mainly includes a pulse power supply and launcher. The parameters of the pulse power supply mainly include the discharge voltage and the capacitance value of the capacitor bank. The structural parameters of the launcher mainly include the bore size of the launcher, the air gap length between the armature and the drive coil, the length and width of the drive coil, and the trigger position of the armature. Change in single or multiple parameters in the launch system will influence the launch performance. The influence of single or multiple parameters on the launch performance was summarized, and the physical law as analyzed. The influence law of the EICL system parameters on the launch performance was obtained, which lays a theoretical foundation for the optimization design of EICL. Finally, experimental verification was carried out by a single-stage test platform.
28 August 2020 in IEEE Transactions on Plasma Science
In this article, the influence of multistage synchronous induction coil launcher (SICL) coupling on diode advance conduction was analyzed. The coil current and launching performance of the SICL which is based on the crowbar circuit was also investigated. The thyristor was connected before diode in this multistage SICL system circuit. First, the precise mathematical model for this two-stage SICL was theoretically deduced. The model was to analyze the effects of coils coupling under different trigger timings on diode advance conduction and coil current. Second, the derivation of the model was based on applying the precise mathematical methods of coils coupling to the process of SICL launching. From this analysis, the effects of coils coupling under fixed trigger timing on coil current and launching performance can be obtained. By comparing the MAXWELL finite-element simulation with MATLAB numerical calculation, we were able to estimate the correctness of the precise mathematical model. Finally, experiments were carried out and the results were well consistent with the simulation results.
2 April 2019 in IEEE Transactions on Plasma Science
To deal with the uneven force on the inner and outer layers of the series coils as well as a large force on and temperature rise in its single layer under the influence of high pulse current during the electromagnetic launch (EML), this paper proposes a method of winding the wires of different diameters and turns by layers to make the multilayer coil parallel and the force on its layer uniform. But the prerequisite for the method is to ensure that the total current in the series coil and new-type coils keeps basically unchanged. The idea of designing the uniform distribution of coil current will provide a new approach to designing coils in the future.
25 December 2019 in IEEE Transactions on Plasma Science
This article aims to deal with the multidegree of freedom (MDOF) of the armature moving in the barrel of a synchronous induction coil launcher (SICL). Based on the analysis of only three degree-of-freedom motions, kinetic equations of the armature are derived theoretically. Then, the finite-element simulation software is used to simulate the MDOF motion of armature in the barrel. According to the theoretical calculation and simulation results, the armature can suspend in the SICL due to the radial force, which confirms that it has a character of self-suspension in the barrel.
18 June 2024 in IEEE Transactions on Plasma Science
With the continuous improvement of the launch energy level of the electromagnetic induction coil launcher (EICL), the muzzle energy is increasing, and the recoil force of the launcher is also increasing. In this article, the mathematical model of EICL is established, and the model of recoil force of the launch system is established according to the recoil phenomenon of the EICL system. On this basis, the mathematical model of the recoil force based on the spring hydraulic buffer device is established. The basic equation of the recoil motion under the action of the recoil mechanism is derived, and the dynamic mathematical model is established. Under the same single-stage EICL model, the recoil law of the launch processing is simulated and calculated, and the recoil motion law curve is obtained when the anti-recoil mechanism is used. The launch performance of the launcher with and without the recoil mechanism is compared. A new damping recoil mechanism is realized, and it is applied to the test system of large energy EICL.