Biao Wang

Prof. Biao Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2023 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
PGPengxiang Ge
Pengxiang Ge
YWYonghong Wang
Yonghong Wang
JZJie Zhou
Jie Zhou
BWBiao Wang
Biao Wang

15 June 2023 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
XLXiangwei Liu
Xiangwei Liu
YWYonghong Wang
Yonghong Wang
LZLiang Zhu
Liang Zhu
BWBiao Wang
Biao Wang
PYPeizheng Yan
Peizheng Yan

30 November 2023 in Optics & Laser Technology
Verified
Journal Article
Closed access
XLXiangwei Liu
Xiangwei Liu
LZLiang Zhu
Liang Zhu
PYPeizheng Yan
Peizheng Yan
BWBiao Wang
Biao Wang
YWYonghong Wang
Yonghong Wang

18 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PGPengxiang Ge
Pengxiang Ge
HWHuanqing Wang
Huanqing Wang
YWYonghong Wang
Yonghong Wang
BWBiao Wang
Biao Wang
The calibration of a multicamera system is a prerequisite for high accuracy measurement. In this study, a method for calibrating a ring multicamera system with a transparent target combined with digital image correlation (DIC) technology is proposed to achieve panoramic dynamic and static measurement of the object. The transparent target is placed in the middle of the ring camera array, and the target can be driven by the turntable to calibrate multiple cameras simultaneously. A complete refraction correction model is built on the transparent side of the target, and the corrected calibration data are integrated into the multi-camera DIC system. The global optimization further improves the overall calibration accuracy of the system. Special markers are attached to the target surface to automatically identify the refractive and non-refractive surfaces of the target. This type of camera can establish coordinate relationship with the cameras on the other side of the target although no overlapping field of view exists between adjacent cameras on the same side of the target. The calibration data are analyzed, and dynamic and static experiments are implemented to verify the measurement accuracy of the system. All experimental results show that the calibration and measurement accuracies of the proposed method are high, and the system can be fully used for high-precision panoramic dynamic and static measurements.

3 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SWShuangle Wu
Shuangle Wu
YYYanfeng Yao
Yanfeng Yao
BWBiao Wang
Biao Wang
YWYonghong Wang
Yonghong Wang
FYFenglong Yang
Fenglong Yang
In current practical applications, synchronously obtaining the information about out-of-plane deformation of double ends is often necessary. However, traditional measurement systems cannot achieve the synchronous measurement of double ends, as two sets of measurement systems are often needed. This study solves the problem by designing a synchronous measurement system for the first derivative of the double-end deformation based on shearography. The first derivative distribution of the double-end deformation is measured synchronically by imaging the two end surfaces in different areas of the camera’s target plane through different shear structures. In addition, by placing apertures in each Michelson shear structure, the synchronous dynamic measurement of both ends and the independent adjustment of the shear and spectral distribution in the Michelson shearography system are realized. The principle of the measurement system is introduced in detail, and the feasibility and practicability of the proposed system are verified by experiments.

31 January 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
YYYanfeng Yao
Yanfeng Yao
YWYonghong Wang
Yonghong Wang
ZZZihua Zheng
Zihua Zheng
BWBiao Wang
Biao Wang
JLJunrui Li
Junrui Li