Historic earthen structures are a significant portion of the built heritage worldwide and are associated with intangible building techniques, wide material availability and low-cost construction. Nonetheless, dueto their low mechanical properties and, often poor connections, historic earthen structures are susceptible to early structural damage, and even collapse in areas of high seismic hazard. Inaddition, the lack of maintenance can further reduce structural performance and durability. The Getty Conservation Institute (GCI)’s Seismic Retrofitting Project (SRP) aims to research, designand test low-tech retrofitting techniques, as well as to implement maintenance programs, enhancing the performance of historicearthen buildings in seismic areas where the most advanced equipment, structural skills and materials are not easily available. Results: Accounting for recommendations from national building codes, conservation principles and local practices, the complete design, assessment and implementation of strengthening for twoprototype buildings in Peru, involved in the SRP, are discussed; the Church of Kuño Tambo and Ica Cathedral. Conclusions: Theretrofitted structures, complied with performance criteria and seismic local demands, with sufficient safety and acceptable levels of repairable damage.
The concepts of structural assessment and retrofit of historical constructions are of particular complexity and require advanced knowledge in material science, conservation techniques and structural analysis. In particular, adobe constructions, given their low mechanical properties and brittle failure modes, are in immense need of comprehensive assessment and retrofitting plans. The current work focuses on the adobe Church of Kuñotambo in Peru, having experienced long periods of deterioration and earthquake-related damage. Under the ongoing Seismic Retrofitting Project (SRP) of the Getty Conservation Institute (GCI), the structural assessment of the church initiated in 2015 confirmed the low lateral capacity of the building and the poor connectivity between the structural parts. Based on the existing cracks and damage, a strengthening scheme was optimized and validated. After the implementation of the retrofitting plan, the quality of its execution and efficiency were assessed in 2019 with a new in situ campaign, which included ambient vibration testing (AVT) and sonic testing. From the acquired field data, the FE model of the retrofitted church was optimized, by updating the stiffness properties of masonry and discontinuities. Moreover, nonlinear static analyses were performed on the updated model in all in-plan directions. Finally, a displacement-based performance assessment was undertaken, under different earthquake limit states, demonstrating the adequacy of the retrofitting.
17 February 2020 in International Journal of Architectural Heritage
Damage in Gothic cathedrals can occur due to single extreme events or long-term processes, often associated with large deformations and cracking. This paper presents the damage survey and structural assessment of a UNESCO world heritage site and one of the oldest, most visited and most known Christian temples in the UK: Canterbury Cathedral, in Kent. Inspection and damage survey showed repetitive crack patterns on the vault’s intrados, with more severity in the south aisle, including outward rotating movement and cracking in the south flying buttresses. Ambient vibration tests were carried out to identify the structure modal properties. An FE model of a typical transversal section of the nave and lateral aisles was prepared, and calibrated based on the tests. Nonlinear static analyses were performed, considering the main parameters of influence to the structure, as the construction process, the infill volume, the presence of lateral thrusts from the nave’s roof and differential settlements. A validated FE model, presenting sufficient correlation with the existing damage was used to determine the safety factors for lateral and vertical loading, which according to the local hazard are considered adequate. A comparison with limit analysis, based on the static approach, was also carried out.
Cultural Heritage Buildings are considered highly complex, having evolved over time, and contain various heritage components. These assets are becoming increasingly at risk due to unprecedented transformation processes in cities, from underground railways. Experimental and monitoring strategies can serve as diagnostic tools on the effects of long-term exposure to induced vibrations, from this new source. The current work presents the Structural Health Monitoring (SHM) outcomes in the Church of the Angels (Igreja dos Anjos), a monument of the early 20th century, in Lisbon, Portugal, directly over a subway station, in a shallow railway line, subjected to groundborne vibration. Criteria from international standards provide threshold values, mostly in terms of velocity, which are linearly related to stress and strain fields. Specific criteria for non-structural components are usually set, accounting among others, frequency bandwidths and levels of intermittency. Even if recommendations specify the velocity as a primary measurement, it is often needed to obtain velocity–time histories from acceleration data, as accelerometers are widely used in practice. Weak signal processing, low sampling frequencies, the type of integration in time or frequency domain and digital filtering, with incorrect cut-off frequency bandwidths, may lead to processed signals, distorted in terms of shape, phase and amplitude.