Neutral point clamped (NPC) multilevel inverter is being used for medium and high power applications since it can synthesize more voltage levels with smaller output voltage steps compared to two level full-bridge inverters. An NPC based multi-level dual-active bridge (ML-DAB) dc-dc converter has been proposed where the low voltage side consists a full-bridge producing a two-level voltage and the high voltage side has two three-level neutral point diode clamped (NPC) switching poles which produce a five-level voltage waveform across the high frequency transformer. Capacitor voltage unbalance has been an important concern for NPC topology. A neutral-point current control scheme has been proposed to control the imbalance between the capacitor voltages in the NPC side. Experimental results for steady-state operation and the capacitor voltage balancing control have been shown in simulation.
A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.
21 May 2024 in Computers and Electrical Engineering
The growing adoption of photovoltaic energy has increased the use of grid‐connected inverter systems, particularly transformerless inverters, due to their cost‐effectiveness and high efficiency. However, these inverters face a persistent challenge in managing leakage current, which can compromise both safety and grid current quality. Thus, effective grid current control and leakage current minimization are essential for enhancing system performance and safety. This study investigates a transformerless grid‐connected H‐bridge neutral point clamped inverter, focusing on leakage current reduction. A super‐twisting algorithm‐based sliding mode control is proposed for grid current regulation, enhanced by a modified modulation scheme, symmetric filter design, and optimized control structure. MATLAB/Simulink simulations validated the system's design and control strategy, demonstrating effective grid current regulation and significant leakage current reduction.
1 March 2024 in Balkan Journal of Electrical and Computer Engineering
With the widespread integration of renewable energy systems (RES) into the electric grid, maintaining power quality within specified limits has become a major focus. The total harmonic distortion (THD) value of the currents transferred to the grid and directly affecting power quality in (RES) such as grid-connected photovoltaic (PV) and fuel cells (FC) should not exceed 5%. To achieve this objective, various filter topologies are used to interface between the inverters, which are components of PV and FC systems, and the grid.Although there are numerous filter topologies, L and LCL-type passive filters are the most commonly used topologies in grid-connected systems. This study analyzes the L and LCL-type filter topologies for the H-bridge neutral point clamped (HNPC) inverter. The study’s modeling was carried out in the MATLAB/Simulink®. By comparing the simulation results, L and LCL filters’ harmonic attenuation capabilities, maximum power transferred to the grid, and effects on grid current have all been investigated.
20 February 2026 in Computers & Industrial Engineering