Objective. To assess the correlation between ultrasound lung comets (ULCs, a recently described echographic sign of interstitial lung fibrosis) and the current undisputed gold-standard high-resolution CT (HRCT) to detect pulmonary fibrosis in patients with SSc. Methods. We enrolled 33 consecutive SSc patients (mean age 54 ± 13 years, 30 females) in the Rheumatology Clinic of the University of Pisa. We assessed ULCs and chest HRCT within 1 week independently in all the patients. ULC score was obtained by summing the number of lung comets on the anterior and posterior chest. Pulmonary fibrosis was quantified by HRCT with a previously described 30-point Warrick score. Results. Presence of ULCs (defined as a total number more than 10) was observed in 17 (51%) SSc patients. Mean ULC score was 37 ± 50, higher in the diffuse than in the limited form (73 ± 66 vs 21 ± 35; P < 0.05). A significant positive linear correlation was found between ULCs and Warrick scores (r = 0.72; P < 0.001). Conclusions. ULCs are often found in SSc, are more frequent in the diffuse than the limited form and are reasonably well correlated with HRCT-derived assessment of lung fibrosis. They represent a simple, bedside, radiation-free hallmark of pulmonary fibrosis of potential diagnostic and prognostic value.
OGon behalf of the OMERACT Ultrasound Gout Task Force group
on behalf of the OMERACT Ultrasound Gout Task Force group
+13
Objective. To produce consensus-based definitions of the US elementary lesions in gout and to test their reliability in a web-based exercise. Methods. The process consisted of two steps. In the first step a written Delphi questionnaire was developed from a systematic literature review and expert international consensus. This collated information resulted in four statements defining US elementary lesions: double contour (DC), tophus, aggregates and erosion. The Delphi questionnaire was sent to 35 rheumatology experts in US, asking them to rate their level of agreement or disagreement with each statement. The second step tested the reliability by a web-exercise. US images of both normal and gouty elementary lesions were collected by the participants. A facilitator then constructed an electronic database of 110 images. The database was sent to the participants, who evaluated the presence/absence of US elementary lesions. A group of 20 images was displayed twice to evaluate intra-reader reliability. Results. A total of 32 participants responded to the questionnaires. Good agreement (>80%) was obtained for US definitions on DC, tophus, aggregates and erosion in the Delphi exercise after three rounds. The reliability on images showed inter-reader κ values for DC, tophus, aggregates, erosion findings of 0.98, 0.71, 0.54 and 0.85, respectively. The mean intra-reader κ values were also acceptable: 0.93, 0.78, 0.65 and 0.78, respectively. Conclusion. This, the first consensus-based US definition of elementary lesions in gout, demonstrated good reliability overall. It constitutes an essential step in developing a core outcome measurement that permits a higher degree of homogeneity and comparability between multicentre studies.
Objectives To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. Methods A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. Results The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. Conclusions Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.
Objective.: To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the new definitions.Methods.: After a systematic literature review, a Delphi survey was circulated among a group of expert ultrasonographers, who were members of the CPPD Ultrasound (US) Outcome Measures in Rheumatology (OMERACT) subtask force, to obtain definitions of the US characteristics of CPPD at the level of fibrocartilage (FC), hyaline cartilage (HC), tendon, and synovial fluid (SF). Subsequently, the reliability of US in assessing CPPD at knee and wrist levels according to the agreed definitions was tested in static images and in patients with CPPD. Cohen’s κ was used for statistical analysis.Results.: HC and FC of the knee yielded the highest interobserver κ values among all the structures examined, in both the Web-based (0.73 for HC and 0.58 for FC) and patient-based exercises (0.55 for the HC and 0.64 for the FC). Kappa values for the other structures were lower, ranging from 0.28 in tendons to 0.50 in SF in the static exercise and from 0.09 (proximal patellar tendon) to 0.27 (triangular FC of the wrist) in the patient-based exercise.Conclusion.: The new OMERACT definitions for the US identification of CPPD proved to be reliable at the level of the HC and FC of the knee. Further studies are needed to better define the US characteristics of CPPD and optimize the scanning technique in other anatomical sites.