Lower limb exoskeletons are becoming increasingly popular for aiding individuals with disabilities or limited locomotion abilities. Existing lower limb exoskeletons mainly focus on walking gait to perform medical rehabilitation training; however, the behavior patterns of patients are diverse, and a single walking gait cannot satisfy the demands of daily life. In order to promote the assisting performance of lower limb exoskeletons subject to various types of gaits, this article proposes a policy improvement with path integrals ( $\rm {PI^{2}}$ )-based adaptive impedance control strategy. Our proposed method employs a hierarchical structure. First, the zero moment point concept is employed to generate the desired angle trajectories of the hip joint and knee joint under three gaits: walking, squatting, and climbing. On this basis, $\rm {PI^{2}}$ optimization is incorporated with the impedance control to track the generated angle trajectory, wherein the impedance parameters are optimized using the deviation between the actual and desired trajectory of the lower limb exoskeleton. The human–robot interaction forces are guaranteed to remain within a small threshold even under various types of gaits. Comparative simulations and exoskeleton wearing experiments are conducted to validate the effectiveness and superiority of the proposed method.
A novel tailless X-type flapping-wing micro air vehicle with two pairs of independent drive wings is designed and fabricated in this paper. Due to the complexity and unsteady of the flapping wing mechanism, the geometric and kinematic parameters of flapping wings significantly influence the aerodynamic characteristics of the bio-inspired flying robot. The wings of the vehicle are vector-controlled independently on both sides, enhancing the maneuverability and robustness of the system. Unique flight control strategy enables the aircraft to have multiple flight modes such as fast forward flight, sharp turn and hovering. The aerodynamics of the prototype is analyzed via the lattice Boltzmann method of computational fluid dynamics. The chordwise flexible deformation of the wing is implemented via designing a segmented rigid model. The clap-and-peel mechanism to improve the aerodynamic lift is revealed, and two air jets in one cycle are shown. Moreover, the dynamics experiment for the novel vehicle is implemented to investigate the kinematic parameters that affect the generation of thrust and maneuver moment via a 6-axis load cell. Optimized parameters of the flapping wing motion and structure are obtained to improve flight dynamics. Finally, the prototype realizes controllable take-off and flight from the ground.
People with upper limb disabilities or high quadriplegia have extremely high requirements for the maneuverability and functionality of power wheelchairs. Normal wheelchairs cannot meet travel tasks, while smart customized wheelchairs are expensive and cannot be popularized. Therefore, a novel extension control instrument for power wheelchairs with low cost, strong scalability, and convenient usage is proposed, which can realize the control of the wheelchair by sensing a change of head posture. The device is divided into a head motion sensing unit (HMSU) and a wheelchair assistance control unit (WACU). The mapping relationship between the head attitude and the subject’s motion intention is established. The inertial measurement module in the HMSU collects the head attitude data and uses the Kalman filtering method to obtain the accurate Euler angle. The WACU is fixed on the original controller of the wheelchair. The joystick is inserted into the extended control mechanism and controlled, instead of the hand, through a 2-degree-of-freedom servo system combined with the pinion and rack push rod structure, thus controlling the movement of the wheelchair. In proceeding, the system can also detect the distance of objects in the environment in real time through the three-direction (front, left, right) ultrasonic ranging sensors installed on the WACU, with a certain obstacle avoidance function. The prototype experiments prove that the extension control instrument developed in this paper based on the Kalman filter can quickly and accurately identify head motion and accurately control the movement of the wheelchair. It is easy to operate and has strong universality, which presents a new low-cost solution for the travel of patients with disabilities.
An adaptive switching controller based on dynamic zero moment point for versatile hip exoskeleton is proposed in this work. The linear finite hysteretic state machine is designed to recognize hybrid motion phases. The torque planning strategy based on dynamic zero moment point is deployed to obtain assistant torque adaptively under different locomotion. Experiments are carried out to verify the performance of the controller, confirming the stability and accuracy of the motion phase recognition, which also demonstrates excellent kinematic performance. The net metabolic rate can be reduced by 5.75% while wearing the versatile hip exoskeleton. Compared with existing research, the performance of the proposed controller has significant advantages. The proposed controller is capable of multiple types of locomotion including flat walking, stair climbing, and lifting heavy objects with low complexity and energy consumption. The Biological and Medical Ethics Committee of Beihang University has approved the experiments.
1 January 2026 in IEEE Transactions on Industrial Electronics