Summary: Background: Root resorption can be considered the most unfortunate complication of orthodontic treatment.Objective: To evaluate the available evidence regarding orthodontically induced inflammatory root resorption (OIIRR).Search methods: A comprehensive literature search was conducted for the systematic reviews investigating OIIRR published up to 24 May 2020. This was accomplished using electronic databases: MEDLINE via OVID, EMBASE, AMED (Allied and Complementary Medicine Database), PubMed, and Web of Science. Any ongoing systematic reviews were searched using Prospero and a grey literature search was undertaken using Google Scholar and OpenGrey (www.opengrey.eu/). No language restriction was applied.Selection criteria: Only studies investigating OIIRR were included.Data collection and analysis: Screening, quality assessment [using the AMSTAR 2 tool (A Measurement Tool to Assess Systematic Reviews)], and data extraction were performed by two authors independently. Information was categorized and narratively synthesized for the key findings from moderate and high-quality reviews.Results: A total of 2033 potentially eligible studies were identified. After excluding the non-relevant studies, 28 systematic reviews were included. Of which, 20 systematic reviews (71.5%) were of moderate and high-quality level of evidence. The incidence and severity of OIIRR increase with the fixed appliance, especially with heavy force, intrusion, torqueing movements, increased treatment duration, and treatment with extractions or with long apical displacement (particularly for maxillary incisors). There was insufficient evidence regarding most other treatment- and patient-related factors on OIIRR. Following all precautionary measures, pausing treatment and regular monitoring benefits patients with OIIRR.Conclusions and implications: There is a limited number of high-quality studies in terms of OIIRR. The influence of fixed appliance on root resorption was noted; however, the cause and effect relationship between OIIRR and orthodontic biomechanics has not been confirmed. Avoiding heavy, continuous forces and a greater amount of apical displacement over a long duration of treatment is recommended. Precautionary measures should be carefully considered when treating patients with a high risk of OIIRR.Registration: CRD42020166629.
22 September 2021 in Journal of Taibah University Medical Sciences
This study compares the accuracy and reliability of WebCeph (web-based program for cephalometric analysis) with the AutoCAD computer software. A sample of pretreatment digital lateral cephalograms of 50 orthodontic patients was analysed with WebCeph and AutoCAD software (as a standard measure). On each cephalogram, 17 landmarks and 11 measurements were marked and performed as skeletal, dental, and soft–tissue parameters. We used six angular and five linear measurements. A paired t-test was used to assess the systematic bias. The intraclass correlation coefficient (ICC) and Bland–Altman plot with linear regression analysis were used to assess the agreement between the two methods. There was adequate reproducibility for the measurements with both WebCeph and AutoCAD. The paired t-test showed statistically significant differences for five angular and two linear measurements (P < 0.05). The ICC test between WebCeph and AutoCAD revealed very good to excellent agreement for all measurements, except for the lower incisor to mandibular plane angle. The Bland–Altman plot visually showed a relatively acceptable limit of agreement for three angular and two linear measurements only, and the linear regression analysis revealed a significant proportional bias between the two methods for four angles and the upper lip-Esthetic line (U Lip-E Line). The systematic bias and level of agreement improved with the use of the semi-automatic WebCeph. Different problems, such as poor landmark identification/soft tissue tracing and inconsistency of measurements, are inherent to the automatic WebCeph. The semi-automatic WebCeph can overcome some limitations of the automatic WebCeph; however, it should be used for cephalometric analysis with a great deal of caution.
To compare the quality of orthodontic treatment between 0.018-inch and 0.022-inch slot bracket systems. Eligible participants aged 12 years or over were allocated to the 0.018-inch or 0.022-inch slot MBT appliance (3M-Unitek, Monrovia, California, USA) using block randomization in groups of 10. Outcome measures included: 1. ABO cast-radiograph evaluation (CR-EVAL), 2. peer assessment rating (PAR) scores, 3. incisor inclination, and 4. patient perception using the Index of Orthodontic Treatment Need aesthetic component (IOTN AC) and three validated questionnaires before, during and after treatment. Parametric tests [independent samples t-test and two-way analysis of variance (ANOVA)] and non-parametric tests (chi-square with Fisher’s exact tests and Mann–Whitney U-test) assessed differences between groups (P < 0.05). Of the 187 participants randomized (1:1 ratio), 34 withdrew or were excluded (protocol deviations or poor cooperation). There were 77 patients in the 0.018-inch slot group and 76 patients in the 0.022-inch slot group (overall mean age: 19.1 years). Baseline characteristics were similar between groups (P > 0.05). The mean total ABO CR-EVAL scores were 34.7 and 34.5; mean percentage PAR score reduction 74.1 per cent and 77.1 per cent; mean change for maxillary incisor inclination 2.9 degrees and 1.6 degrees and for mandibular incisor inclination 2.7 degrees and 1.4 degrees for the 0.018-inch and 0.022-inch groups, respectively. Improvement in patient perception of aesthetics after treatment was statistically significant for both groups (P < 0.05). However, there were no statistically significant differences between the two treatment groups for ABO CR-EVAL, percentage PAR score reduction, incisor inclination, and patient perception of treatment (P > 0.05). No adverse events were observed during treatment. It was impossible to blind clinicians or patients to allocation and oral hygiene and periodontal outcomes were not assessed. There were no statistically or clinically significant differences in the quality of occlusal outcomes, incisor inclination and patient perception of treatment between 0.018-inch and 0.022-inch slot bracket systems. The trial was registered with ClinicalTrials.gov on 5 March 2014, registration number: NCT02080338. The protocol was published at DOI: 10.1186/1745-6215-15-389.
1 September 2022 in European Journal of Orthodontics
White spot lesions (WSLs) are the most common complications of fixed appliance orthodontic treatment. To evaluate the effectiveness of calcium fluoride nanoparticles-containing orthodontic primer (nCaF2-primer) in preventing the incidence of WSLs during orthodontic treatment. Single-centre, double-blinded, split-mouth, randomized clinical trial. The sample involved 31 orthodontic patients (≥12 years). Participants were recruited using a simple nonstratified randomization. Data collection, measurements, and analysis were performed blindly. Outcome measures included comparing the effect of nCaF2-primer with control primer (Transbond) regarding the degree of demineralization (DIAGNOdent pen), Streptococcus mutans (S. mutans) bacterial counting [real-time polymerase chain reaction device (PCR)], and WSLs incidence (pre- and post-operative photographs). The measurements were performed before bonding, 1, 3, and 6 months after bonding and after appliance removal. A two-way repeated measure analysis of variance test (for DIAGNOdent pen scores), and Wilcoxon signed-rank test (for the difference between bacterial counting and WSLs incidence) were used (P < 0.05). Thirty-one patients were recruited and randomized (mean age 17.9 ± 2.45 years). For the primary outcome (DIAGNOdent pen scores) and secondary outcome of S. mutans counting: 31 patients (310 teeth for each group) were included in scoring at T1 and T3, and 30 patients (300 teeth) were included at T6. While for the photographic scores, 26 patients were included after bracket bonding. The demineralization scores showed significant differences at all-time intervals within the 6 months after bracket bonding which was more noticeable after the first month. There was a significant difference in bacterial count between the two primer groups at the T1 only. Regarding photographic scores, there were no significant differences in the WSLs incidence between the two primers groups after brackets removal. No harm was detected during treatment, except the usual pain/gingival irritation. nCaF2-primer effectively decreased demineralization scores within the 6 months after bracket bonding. Moreover, it significantly reduced S. mutans colonization after the first month. However, the tested primer did not have an extra advantage in preventing WSLs development at the clinical level after appliance removal. The trial was registered with ClinicalTrials.gov on 8 May 2021 (registration number: NCT04994314).
1 October 2021 in Journal of the Mechanical Behavior of Biomedical Materials