There is great need for high intensity proton beams from compact particle accelerators in particle physics, medical isotope production, and materials- and energy-research. To address this need, we present, for the first time, a design for a compact isochronous cyclotron that will be able to deliver 10 mA of 60 MeV protons—an order of magnitude higher than on-market compact cyclotrons and a factor four higher than research machines. A key breakthrough is that vortex motion is incorporated in the design of a cyclotron, leading to clean extraction. Beam losses on the septa of the electrostatic extraction channels stay below 120 W (40% below the required safety limit), while maintaining good beam quality. We present a set of highly accurate particle-in-cell simulations, and an uncertainty quantification of select beam input parameters using machine learning, showing the robustness of the design. This design can be utilized for beams for experiments in particle and nuclear physics, materials science and medical physics as well as for industrial applications.
18 November 2015 in Review of Scientific Instruments
IsoDAR (Isotope Decay-At-Rest) is a novel experiment designed to measure neutrino oscillations through disappearance, thus providing a definitive search for sterile neutrinos. In order to generate the necessary anti-neutrino flux, a high intensity primary proton beam is needed. In IsoDAR, H is accelerated and is stripped into protons just before the target, to overcome space charge issues at injection. As part of the design, we have refined an old proposal to use a RFQ to axially inject bunched H ions into the driver cyclotron. This method has several advantages over a classical low energy beam transport (LEBT) design: (1) The bunching efficiency is higher than for the previously considered two-gap buncher and thus the overall injection efficiency is higher. This relaxes the constraints on the H current required from the ion source. (2) The overall length of the LEBT can be reduced. (3) The RFQ can also accelerate the ions. This enables the ion source platform high voltage to be reduced from 70 kV to 15 kV, making underground installation easier. We are presenting the preliminary RFQ design parameters and first beam dynamics simulations from the ion source to the spiral inflector entrance.
IsoDAR@Yemilab is a novel isotope-decay-at-rest experiment that has preliminary approval to run at the Yemi underground laboratory (Yemilab) in Jeongseon-gun, South Korea. Here, we describe in detail the considerations for installing this compact particle accelerator and neutrino target system at the Yemilab underground facility. Specifically, we describe the caverns being prepared for IsoDAR, and address installation, shielding, and utilities requirements. To give context and for completeness, we also briefly describe the physics opportunities of the IsoDAR neutrino source when paired with the Liquid Scintillator Counter (LSC) at Yemilab, and review the technical design of the neutrino source.
1 December 2021 in Review of Scientific Instruments
We report the results from a new multicusp ion source (MIST-1) that produces record steady-state currents of (1 mA) from this type of ion source with high purity (80% ). We built MIST-1 to fulfill the stringent beam purity and beam quality requirements for IsoDAR, a proposed discovery-level neutrino experiment, requiring a 10 mA, 60 MeV/amu continuous wave (cw) proton beam on the target. IsoDAR will use a cyclotron accelerating ions and using a novel radio frequency quadrupole (RFQ) direct injection method. Systematic measurements, varying discharge voltage, discharge current, and gas pressure, indicate that the ideal operating regime is at low pressure, high discharge current, and high discharge voltage. We have measured the combined species emittance after the source extraction to be π-mm-mrad (rms, normalized) for a 0.95 mA beam. Beyond showing high currents and high fraction, our measurements agree well with high fidelity simulations. These results show the feasibility of using a multicusp ion source for IsoDAR and the RFQ direct injection prototype and paves the way to record breaking cw beam currents of 5 mA (equivalent to 10 mA protons) from compact cyclotrons, ideal for underground installation.
11 December 2017 in Physical Review Accelerators and Beams
We present an upgrade to the particle-in-cell ion beam simulation code opal that enables us to run highly realistic simulations of the spiral inflector system of a compact cyclotron. This upgrade includes a new geometry class and field solver that can handle the complicated boundary conditions posed by the electrode system in the central region of the cyclotron both in terms of particle termination, and calculation of self-fields. Results are benchmarked against the analytical solution of a coasting beam. As a practical example, the spiral inflector and the first revolution in a test cyclotron, located at Best Cyclotron Systems, Inc., are modeled and compared to the simulation results. We find that opal can now handle arbitrary boundary geometries with relative ease. Simulated injection efficiencies and beam shape compare well with measured efficiencies and a preliminary measurement of the beam distribution after injection.