Andre R. Brunoni

Dr. Andre R. Brunoni

Institute of Psychiatry, School of Medicine, University of São Paulo, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Brain Stimulation
Verified
Journal Article
Closed access
MBMarom Bikson
Marom Bikson
PGPnina Grossman
Pnina Grossman
CTChris Thomas
Chris Thomas
AZAdantchede Louis Zannou
Adantchede Louis Zannou
JJJimmy Jiang
Jimmy Jiang
AWAdam J. Woods
Adam J. Woods

1 February 2016 in Clinical Neurophysiology
Verified
Journal Article
Open access
AWA.J. Woods
A.J. Woods
AAA. Antal
A. Antal
MBM. Bikson
M. Bikson
PBP.S. Boggio
P.S. Boggio
ABAndre R. Brunoni
Andre R. Brunoni
MNM.A. Nitsche
M.A. Nitsche
Transcranial electrical stimulation (tES), including transcranial direct and alternating current stimulation (tDCS, tACS) are non-invasive brain stimulation techniques increasingly used for modulation of central nervous system excitability in humans. Here we address methodological issues required for tES application. This review covers technical aspects of tES, as well as applications like exploration of brain physiology, modelling approaches, tES in cognitive neurosciences, and interventional approaches. It aims to help the reader to appropriately design and conduct studies involving these brain stimulation techniques, understand limitations and avoid shortcomings, which might hamper the scientific rigor and potential applications in the clinical domain.

1 September 2017 in Clinical Neurophysiology
Verified
Journal Article
Open access
AAAndrea Antal
Andrea Antal
IAI. Alekseichuk
I. Alekseichuk
MBM. Bikson
M. Bikson
JBJ. Brockmöller
J. Brockmöller
ABAndre R. Brunoni
Andre R. Brunoni
WPW. Paulus
W. Paulus
Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears to be safe. No serious adverse events (SAEs) have been reported so far in over 18,000 sessions administered to healthy subjects, neurological and psychiatric patients, as summarized here. Moderate adverse events (AEs), as defined by the necessity to intervene, are rare, and include skin burns with tDCS due to suboptimal electrode-skin contact. Very rarely mania or hypomania was induced in patients with depression (11 documented cases), yet a causal relationship is difficult to prove because of the low incidence rate and limited numbers of subjects in controlled trials. Mild AEs (MAEs) include headache and fatigue following stimulation as well as prickling and burning sensations occurring during tDCS at peak-to-baseline intensities of 1-2mA and during tACS at higher peak-to-peak intensities above 2mA. The prevalence of published AEs is different in studies specifically assessing AEs vs. those not assessing them, being higher in the former. AEs are frequently reported by individuals receiving placebo stimulation. The profile of AEs in terms of frequency, magnitude and type is comparable in healthy and clinical populations, and this is also the case for more vulnerable populations, such as children, elderly persons, or pregnant women. Combined interventions (e.g., co-application of drugs, electrophysiological measurements, neuroimaging) were not associated with further safety issues. Safety is established for low-intensity 'conventional' TES defined as <4mA, up to 60min duration per day. Animal studies and modeling evidence indicate that brain injury could occur at predicted current densities in the brain of 6.3-13A/m2 that are over an order of magnitude above those produced by tDCS in humans. Using AC stimulation fewer AEs were reported compared to DC. In specific paradigms with amplitudes of up to 10mA, frequencies in the kHz range appear to be safe. In this paper we provide structured interviews and recommend their use in future controlled studies, in particular when trying to extend the parameters applied. We also discuss recent regulatory issues, reporting practices and ethical issues. These recommendations achieved consensus in a meeting, which took place in Göttingen, Germany, on September 6-7, 2016 and were refined thereafter by email correspondence.

1 July 2012 in Brain Stimulation
Verified
Journal Article
Closed access
ABAndre R. Brunoni
Andre R. Brunoni
MNMichael A. Nitsche
Michael A. Nitsche
NBNadia Bolognini
Nadia Bolognini
MBMarom Bikson
Marom Bikson
TWTim Wagner
Tim Wagner
Felipe FregniFelipe Fregni
Felipe Fregni

1 September 2011 in International Journal of Neuropsychopharmacology
Verified
Journal Article
Open access
PDF file
ABAndre R. Brunoni
Andre R. Brunoni
JAJoao Amadera
Joao Amadera
BBBruna Berbel
Bruna Berbel
MVMagdalena Sarah Volz
Magdalena Sarah Volz
BRBrenno Gomes Rizzerio
Brenno Gomes Rizzerio
Felipe FregniFelipe Fregni
Felipe Fregni
Transcranial direct current stimulation (tDCS) is a non-invasive method of brain stimulation that has been intensively investigated in clinical and c

1 December 2008 in International Journal of Neuropsychopharmacology
Verified
Journal Article
Open access
PDF file
ABAndre R. Brunoni
Andre R. Brunoni
MLMariana Lopes
Mariana Lopes
Felipe FregniFelipe Fregni
Felipe Fregni
Several clinical studies on major depressive disorder (MDD) have shown that blood brain-derived neurotrophic factor (BDNF) – a factor used to index ne