The quantitative prediction of the SYNTAX score for cardiovascular artery disease patients using the inverse problem algorithm (IPA) technique in artificial intelligence was explored in this study. A 29-term semi-empirical formula was defined according to seven risk factors: (1) age, (2) mean arterial pressure, (3) body surface area, (4) pre-prandial blood glucose, (5) low-density-lipoprotein cholesterol, (6) Troponin I, and (7) C-reactive protein. Then, the formula was computed via the STATISTICA 7.0 program to obtain a compromised solution for a 405-patient dataset with a specific loss function [actual-predicted]2 as low as 3.177, whereas 0.0 implies a 100% match between the prediction and observation via “the lower, the better” principle. The IPA technique first created a data matrix [405 × 29] from the included patients’ data and then attempted to derive a compromised solution of the column matrix of 29-term coefficients [29 × 1]. The correlation coefficient, r2, of the regression line for the actual versus predicted SYNTAX score was 0.8958, showing a high coincidence among the dataset. The follow-up verification based on another 105 patients’ data from the same group also had a high correlation coefficient of r2 = 0.8304. Nevertheless, the verified group’s low derived average AT (agreement) (ATavg = 0.308 ± 0.193) also revealed a slight deviation between the theoretical prediction from the STATISTICA 7.0 program and the grades assigned by clinical cardiologists or interventionists. The predicted SYNTAX scores were compared with earlier reported findings based on a single-factor statistical analysis or scanned images obtained by sonography or cardiac catheterization. Cardiologists can obtain the SYNTAX score from the semi-empirical formula for an instant referral before performing a cardiac examination.
Object: Optimization of common iliac artery sonography images using an indigenous water phantom and Taguchi’s analysis was successfully performed to improve the diagnostic accuracy in routine cardiac examination. Methods: A water phantom with two major compartments was developed, which satisfied Taguchi’s unique criterion of optimization analysis. Two or three levels were assigned to five factors, namely, (A) the probe angle, (B) water depth, (C) sonography preset frame rate, (D) amplitude gain, and (E) imaging compression ratio. The resulting Taguchi’s L18 orthogonal array contained 18 combinations of 5 factors, ensuring the same confidence level as a realm of 162 (21 × 34) combinations. The signal-to-noise ratio (S/N) was defined as the minimal difference between the practical survey and predicted areas of 50 mm2 for the sonography imaging scans. The artifact was customized by creating stenosis with a diameter of 8 mm inside a silicon pipe with a diameter of 19 mm. Results: The derived optimal parameters included (A) a zero probe angle, (B) water depth of 6 cm, (C) frame rate of 45 Hz, (D) amplitude gain of 50%, and (E) compress ratio of 50% from 3 independent measurements in each group. Further ANOVA confirmed that the frame rate was a dominant factor, with ss (sum of squared variances) of 56.6%, whereas the error and other terms were suppressed to 20.3% and 11.9%, respectively. The risks of the inappropriate setting of S/N were also discussed to avoid any misinterpretations. Conclusions: The quantified water phantom combined with Taguchi’s approach proved to be instrumental in optimizing the sonography image scan quality in routine cardiac examination.
This study optimized the ultrasound image of carotid artery stenosis using Taguchi dynamic analysis and an indigenous water phantom. Eighteen combinations of seven essential factors of the ultrasound scan facility were organized according to Taguchi’s L18 orthogonal array. The seven factors were assigned as follows: (1) angle of probe; (2) signal gain; (3) resolution vs. speed; (4) dynamic range; (5) XRES; (6) zoom; (7) time gain compensation. An indigenous water phantom was customized to satisfy the quantified need in Taguchi’s analysis. Unlike the conventional dynamic Taguchi analysis, an innovative quantified index, the figure of merit (FOM), was proposed to integrate four specific quality characteristics, namely (i) average difference between the practical scan and theoretically preset area (78.5, 50.2 and 12.6 mm2) of stenosis, (ii) standard deviation of the average, (iii) practical scan’s sensitivity β to various stenosis diameters (10, 8, and 4 mm), and (iv) correlation coefficient r2 of the linear regressed sensitivity curve. The highest value (FOM = 0.413) was furnished by the optimal combination of factors on 18 groups under study, yielding high r2 and low β or standard deviation values and the best quality of ultrasound images for the further clinical diagnosis. The comparison between FOM and the conventional signal-to-noise (S/N) ratio in Taguchi’s analysis revealed that FOM compiled more quality characteristics that were superior by nature to fulfill the practical need in clinical diagnosis. The alternative choice in ultrasound scan optimization can be based on stenosis diameter variation from a different perspective to be explored in the follow-up study.
The thyroid biokinetic model of radioactive I-131 was re-evaluated using a refined nine-compartmental model and applied to twelve thyroid cancer patients. In contrast to the simplified four-compartmental model regulated by the ICRP-56 report, the revised model included nine compartments specified in the ICRP-128 report, namely, oral, stomach, body fluid, thyroid, whole body, liver, kidney, bladder, and remainder (i.e., the whole body minus kidney and bladder). A self-developed program run in MATLAB was designed to solve the nine first-order simultaneous linear differential equations. The model was realized in standard and simplified versions. The latter neglected two feedback paths (body fluid to oral, i31, and kidney to the whole body, i87) to reduce computations. Accordingly, the biological half-lives for the major compartments (thyroid and body fluid + whole body) were 36.00 ± 15.01, 15.04 ± 5.63, 34.33 ± 15.42, and 14.83 ± 5.91 of standard and simplified version. The correlations between theoretical and empirical data for each patient were quantified by the dimensionless AT (agreement) index and, the ATtot index integrated each individual AT of a specific organ of one patient. Since small AT values indicated a closer correlation, the obtained range of ATtot (0.048 ± 0.019) proved the standard model’s reliability and high accuracy, while the simplified one yielded slightly higher ATtot (0.058 ± 0.023). The detailed outcomes among various compartments of twelve patients were calculated and compared with other researchers’ work. The correlation results on radioactive I-131 evolution in thyroid cancer patients’ bodies are instrumental in viewpoint of radioactive protection of patients and radiological personnel.