Yangkyu Park

Prof. Dr. Yangkyu Park


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JYJoho Yun
Joho Yun
GKGiseok Kang
Giseok Kang
Yangkyu ParkYangkyu Park
Yangkyu Park
HKHyeon Woo Kim
Hyeon Woo Kim
JCJung-Joon Cha
Jung-Joon Cha
JLJong-Hyun Lee
Jong-Hyun Lee

1 August 2015 in Journal of Endourology
Verified
Journal Article
Closed access
CPChang-Ju Park
Chang-Ju Park
HKHyeon-Woo Kim
Hyeon-Woo Kim
SJSangdo Jeong
Sangdo Jeong
SSSeungwan Seo
Seungwan Seo
Yangkyu ParkYangkyu Park
Yangkyu Park
JLJong-Hyun Lee
Jong-Hyun Lee
This article aims to describe the design of an anti-reflux ureteral stent with a polymeric flap valve and the fabrication methods using three-dimensional (3D) printing. The stent effectively prevents backward flow with a negligible reduction in forward flow. Fabrication of miniaturized valves was easy with high precision and rapid prototyping. The proposed stent comprised a 7F Double-J (DJ) stent and a polymeric flap valve. The valve was made of Tango Plus FLX980 and was fabricated using a 3D printer. Two types of stent were prepared for in vitro tests: DJ stents with (1) an uncoated valve (UCV) stent and (2) a parylene C coated valve (PCV) stent for enhanced biocompatibility. The flow characteristics of each stent were evaluated considering flow direction, parylene coating, and stent side holes, and were compared to the intact DJ stent. The forward flow rate for the distal portion of the UCV and PCV stents was 9.8 mL/min and 7.8 mL/min at applied pressure of 15 cm H2O (normal anterograde pressure in patients with stents), respectively. Backward flow rate for the distal portion of the UCV and PCV stents was decreased by 28 times and 8 times at applied pressure of 50 cm H2O (maximum bladder pressure), respectively, compared with the distal portion of the intact DJ stent. Forward flow rates of whole stents were 22.2 mL/min (UCV stent) and 20.0 mL/min (PCV stent) at applied pressure of 15 cm H2O, and backward flow rates of whole UCV and PCV stents were decreased by 8.3 times and 4.0 times at applied pressure of 50 cm H2O, respectively, compared with the intact DJ stent. The anti-reflux ureteral stent was successfully designed and fabricated using a 3D printer. In vitro studies showed that the stent effectively prevented backward flow while minimizing reduction in forward flow.

1 July 2020 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
DLDongkyu Lee
Dongkyu Lee
JKJiae Kim
Jiae Kim
Yangkyu ParkYangkyu Park
Yangkyu Park
KLKang-Ho Lee
Kang-Ho Lee
CKChangwon Kim
Changwon Kim
SLSang-Ryong Lee
Sang-Ryong Lee

1 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Yangkyu ParkYangkyu Park
Yangkyu Park
HKHyeon Woo Kim
Hyeon Woo Kim
JYJoho Yun
Joho Yun
SSSeungwan Seo
Seungwan Seo
CPChang-Ju Park
Chang-Ju Park
JLJong-Hyun Lee
Jong-Hyun Lee
Purpose. To distinguish between normal (SV-HUC-1) and cancerous (TCCSUP) human urothelial cell lines using microelectrical impedance spectroscopy (μEIS). Materials and Methods. Two types of μEIS devices were designed and used in combination to measure the impedance of SV-HUC-1 and TCCSUP cells flowing through the channels of the devices. The first device (μEIS-OF) was designed to determine the optimal frequency at which the impedance of two cell lines is most distinguishable. The μEIS-OF trapped the flowing cells and measured their impedance at a frequency ranging from 5 kHz to 1 MHz. The second device (μEIS-RT) was designed for real-time impedance measurement of the cells at the optimal frequency. The impedance was measured instantaneously as the cells passed the sensing electrodes of μEIS-RT. Results. The optimal frequency, which maximized the average difference of the amplitude and phase angle between the two cell lines (p<0.001), was determined to be 119 kHz. The real-time impedance of the cell lines was measured at 119 kHz; the two cell lines differed significantly in terms of amplitude and phase angle (p<0.001). Conclusion. The μEIS-RT can discriminate SV-HUC-1 and TCCSUP cells by measuring the impedance at the optimal frequency determined by the μEIS-OF.

19 May 2016 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
JYJoho Yun
Joho Yun
HKHyeon Woo Kim
Hyeon Woo Kim
Yangkyu ParkYangkyu Park
Yangkyu Park
JCJung-Joon Cha
Jung-Joon Cha
JLJeong Zoo Lee
Jeong Zoo Lee
JLJong-Hyun Lee
Jong-Hyun Lee
The ex-vivo discrimination between human normal and cancer renal tissues was confirmed using μEoN (micro electrical impedance spectroscopy-on-a-needle) by measuring and comparing the electrical impedances in the frequency domain. To quantify the extent of discrimination between dissimilar tissues and to determine the optimal frequency at which the discrimination capability is at a maximum, discrimination index (DI) was employed for both magnitude and phase. The highest values of DI for the magnitude and phase were 5.15 at 1 MHz and 3.57 at 1 kHz, respectively. The mean magnitude and phase measured at the optimal frequency for normal tissues were 5013.40 ± 94.39 Ω and −68.54 ± 0.72°, respectively; those for cancer tissues were 4165.19 ± 70.32 Ω and −64.10 ± 0.52°, respectively. A statistically significant difference (p< 0.05) between the two tissues was observed at all the investigated frequencies. To extract the electrical properties (resistance and capacitance) of these bio-tissues through curve fitting with experimental results, an equivalent circuit was proposed based on the μEoN structure on the condition that the μEoN was immersed in the bio-tissues. The average and standard deviation of the extracted resistance and capacitance for the normal tissues were 6.22 ± 0.24 kΩ and 280.21 ± 32.25 pF, respectively, and those for the cancer tissues were 5.45 ± 0.22 kΩ and 376.32 ± 34.14 pF, respectively. The electrical impedance was higher in the normal tissues compared with the cancer tissues. The μEoN could clearly discriminate between normal and cancer tissues by comparing the results at the optimal frequency (magnitude and phase) and those of the curve fitting (extracted resistance and capacitance).

6 May 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
Yangkyu ParkYangkyu Park
Yangkyu Park
SMSeunghwan Moon
Seunghwan Moon
JLJaekwon Lee
Jaekwon Lee
KKKwanghyun Kim
Kwanghyun Kim
SLSang-Jin Lee
Sang-Jin Lee
JLJong-Hyun Lee
Jong-Hyun Lee
We present an electromagnetically driven microscanner based on a gimbal-less twist mechanism. In contrast to conventional microscanners using a gimbal-less leverage mechanism, our device utilizes a gimbal-less twist mechanism to increase the scan angle in optical applications requiring a large scanning mirror. The proposed gimbal-less scanner with twist mechanism increases the scan angle by 1.55 and 1.97 times for the slow and fast axes, respectively, under the same force; 3.64 and 1.97 times for the slow and fast axes, respectively, under the same maximum stress, compared to the gimbal-less leverage mechanism. The scanner with a 3-mm-diameter mirror and a current path composed of a single-turn coil was fabricated, and it showed the maximum scan angle of 5° (quasi-static) and 22° (resonant) for the slow and fast axes, respectively. The experimentally estimated crosstalk was as small as 0.47% and 0.97% for the fast and slow axes affected by the other axes, respectively, which was determined using a newly employed methodology based on fast Fourier transform.