The Preserflo MicroShunt represents a novel glaucoma treatment device, necessitating long-term follow-up data to accurately assess its efficacy. The aim of this study is to report real-world data of a heterogenous glaucoma cohort who received Preserflo implantation at a specialized glaucoma clinic. A total of 160 eyes of 160 patients who underwent Preserflo MicroShunt implantation were retrospectively enrolled in this study. Patient characteristics, as well as success and failure rates, were assessed. The numbers of adverse events and revision procedures were recorded, along with any reduction in supplementary medication. The progression of intraocular pressure (IOP) was assessed over the course of 12 months, and fluctuations were analyzed. The overall success rate was 61.9% (complete success: 51.3%, qualified success: 10.6%). Revision surgery was performed in 25% of cases. Excessive hypotony occurred postoperatively in 54.4% of patients and regressed after 7 days in 88.8% of all cases. Median IOP decreased from 22 (interquartile range (IQR): 17–27) mmHg preoperatively to 14 (IQR 12–16) mmHg at 12 months postoperatively (p < 0.01). The median number of antiglaucomatous agents decreased from three to zero at latest follow-up. The Preserflo MicroShunt achieved a noticeable reduction in IOP over the course of 12 months in glaucoma patients, irrespective of disease severity or disease subtype. The frequency of postoperative adverse events and number for revision surgeries over the course of the follow-up period were low.
Background: To investigate whether vaccination against SARS-CoV-2 is associated with the onset of retinal vascular occlusive disease (RVOD). Methods: In this multicentre study, data from patients with central and branch retinal vein occlusion (CRVO and BRVO), central and branch retinal artery occlusion (CRAO and BRAO), and anterior ischaemic optic neuropathy (AION) were retrospectively collected during a 2-month index period (1 June–31 July 2021) according to a defined protocol. The relation to any previous vaccination was documented for the consecutive case series. Numbers of RVOD and COVID-19 vaccination were investigated in a case-by-case analysis. A case–control study using age- and sex-matched controls from the general population (study participants from the Gutenberg Health Study) and an adjusted conditional logistic regression analysis was conducted. Results: Four hundred and twenty-one subjects presenting during the index period (61 days) were enrolled: one hundred and twenty-one patients with CRVO, seventy-five with BRVO, fifty-six with CRAO, sixty-five with BRAO, and one hundred and four with AION. Three hundred and thirty-two (78.9%) patients had been vaccinated before the onset of RVOD. The vaccines given were BNT162b2/BioNTech/Pfizer (n = 221), followed by ChadOx1/AstraZeneca (n = 57), mRNA-1273/Moderna (n = 21), and Ad26.COV2.S/Johnson & Johnson (n = 11; unknown n = 22). Our case–control analysis integrating population-based data from the GHS yielded no evidence of an increased risk after COVID-19 vaccination (OR = 0.93; 95% CI: 0.60–1.45, p = 0.75) in connection with a vaccination within a 4-week window. Conclusions: To date, there has been no evidence of any association between SARS-CoV-2 vaccination and a higher RVOD risk.
Glaucoma is one of the leading causes of irreversible blindness globally and is characterized by the gradual loss of retinal ganglion cells. The primary risk factor for the development and progression of glaucoma is increased intraocular pressure (IOP). Numerous surgical interventions exist to lower IOP should conservative therapy fail. One trend in recent years has been minimally invasive glaucoma surgery (MIGS) as an alternative to traditional methods. The ISTENT inject® is an ab interno trabecular micro-bypass implant designed to be implanted through the trabecular meshwork into the Schlemm’s canal to lower IOP. The aim of the study was the postoperative visualization and description of the positioning of the ISTENT inject® using automated circumferential goniophotography. Patients with symptomatic cataracts and mild to moderate primary open-angle glaucoma (POAG), pseudoexfoliation glaucoma (PEX), and pigment-dispersion glaucoma were included who underwent combined cataract surgery with the ISTENT inject® and received postoperative automated gonioscopy with the NIDEK Gonioscope GS-1 to visualize the location of the implant. Twenty-four implants of 14 eyes in 11 patients could be visualized. Out of the implants, 14.3% were in the trabecular meshwork, 46.4% were at the border between the trabecular meshwork and scleral spur, 25% were below the trabecular meshwork, and 14.3% of the implants were not detectable in the gonioscopy. In the overall cohort, a statistically significant IOP reduction was found over the 12-month postoperative observation period. Even in three eyes, in each of which both stents were located below the trabecular meshwork, an IOP reduction over 12 months was observed compared to the baseline IOP. In this study, vertical two-dimensional positioning of the ISTENT inject® was performed for the first time using NIDKE GS-1 automated 360° goniophotography. The method is suitable for postoperative visualization, control, and documentation of positioning after ISTENT inject® implantation. Further studies are needed to analyze the correlation between positioning of the ISTENT inject® in the chamber angle and postoperative IOP reduction.
Purpose: Recent studies have questioned the traditional view, which regards Coats disease as a strictly unilateral entity. Applying optical coherence tomography angiography, this prospective, monocentric study investigates quantitative capillary changes of the macula associated with Coats disease. Methods: Twenty-four eyes (4 untreated, 8 pre-treated) of 12 patients with stage 2 Coats disease (age range: 9–61 years) and 15 eyes of healthy, age-matched controls from the University of Muenster Medical Center, Germany received macular optical coherence tomography angiography measurements of the superficial, deep, and choriocapillary capillary plexus. Flow density and parameters related to the foveal avascular zone were compared between Coats eyes and fellow eyes, and between fellow eyes and control eyes. Additional subanalyses investigated changes based on disease stage. Results: Flow density did not differ between fellow eyes of Coats disease patients and control eyes in any of the parameters investigated. Comparison of Coats eyes to their respective fellow eyes revealed Coats disease to be associated with lower flow density in superficial, deep, and choriocapillary capillary plexus regions, irrespective of disease stage (all P < 0.03). There were no noticeable differences regarding the size or symmetry of the foveal avascular zone. Conclusion: In light of the recent discussion around the unilateral character of Coats disease, this trial provides evidence against a bilateral presentation of vascular changes in the macula.
Background/Objectives: To compare the efficacy and safety of Hydrus® Microstent and iStent inject® W implants, in combination with phacoemulsification, for lowering intraocular pressure (IOP) in patients with glaucoma in a real-world clinical setting. Methods: This retrospective, single-center study analyzed medical records of glaucoma patients who underwent either Hydrus® Microstent or iStent inject® W implantation combined with cataract surgery at the University Hospital Muenster, Germany. Key outcome measures included absolute and relative IOP reduction, reduction in topical antiglaucoma medication use, overall success rate, and complications. A total of 32 eyes were analyzed, 16 in each treatment group, with a 12-month follow-up. Results: Both groups demonstrated significant postoperative IOP reduction (Hydrus: p < 0.001; iStent inject® W: p = 0.032). The Hydrus group achieved significantly greater relative IOP reduction compared to the iStent inject® W group (p = 0.043). The Hydrus group also showed a significant reduction in daily antiglaucoma medication use (p = 0.002), whereas the iStent inject® W group did not achieve statistical significance in this regard (p = 0.054). The overall success rate was higher in the Hydrus group (38%) than in the iStent inject® W group (13%), though the difference was not statistically significant (p = 0.102). No device-related complications were observed in either group. Conclusions: The Hydrus® Microstent demonstrated superior IOP reduction and a more significant reduction in the need for antiglaucoma medications compared to the iStent inject® W in a real-world setting. These findings support the use of the Hydrus implant as an effective and safe micro-invasive glaucoma surgery (MIGS) option for patients with mild to moderate POAG. Further studies with larger patient populations and long-term follow-up are warranted to confirm the efficacy in patients with PEX and advanced glaucoma.
This study aimed to evaluate foveal avascular zone (FAZ) features and macular flow density (FD) in various retinal layers in a cohort of patients with foveal hypoplasia (FH) using optical coherence tomography angiography (OCTA), in order to characterize microvascular abnormalities and explore their potential clinical significance. FAZ parameters and FD, as well as retinal thickness and volume values were analyzed and compared between patients with FH and an age- and gender-matched control cohort. Correlations between disease severity and visual acuity (VA), as well as between disease severity and FAZ features were evaluated. A total of 19 eyes with FH and 19 control eyes were included. The study group showed significantly higher FD values in the foveal sectors of the superficial and deep capillary plexus compared to controls. FAZ area, perimeter, and acircularity index (ACI) were noticeably altered in eyes with FH; however, they did not correlate with disease severity. Visual acuity was negatively correlated with disease severity. The results of this study provide evidence of altered microvasculature architecture specifically in the foveal sectors of patients with FH. The higher FD values in the foveal sectors of FH patients suggest a potential compensatory response of the retinal microvasculature. FAZ parameters and FD values of the foveal sectors could be used as part of an OCTA-based grading system in FH patients.