Power harmonic noise is the main noise interference source in transient electromagnetic (TEM) surveys in the urban environment. State of the art techniques, such as the traditional bipolar waves and superposition average without distorting the TEM signal, are mainly used in the TEM method to process power harmonic noise, but the effect of this method becomes very poor when the fundamental frequency of power harmonic noise fluctuates. To solve the problem, we propose the same phase and adjacent power harmonic noise subtraction method with bipolar waves of specific working frequency. Taking the fluctuation of harmonic frequency into account, the accurate fundamental frequency of power harmonic noise is obtained by the wavelet-Nyman, Gaiser, and Saucier estimator. In addition, we adjust the TEM working frequency and duty cycle according to the fundamental frequency to ensure that the power harmonic noises in the adjacent bipolar data have the same phase, and the adjacent bipolar signals are subtracted to suppress the power harmonic noise in one emitting cycle. In order to verify the effectiveness of the new method, we use a synthetic TEM signal embedded in simulation data and actual collected data for testing. The experimental results show that power harmonic noise with the fundamental frequency fluctuation can be removed efficiently without distorting the TEM signal, and the new method performs better than traditional standard methods.
The observed data of transient electromagnetic (TEM) systems is often contaminated by various noises. Even after stacking averages or applying various denoising algorithms, the interference of the system noise floor cannot be eliminated fundamentally, which limits the survey capability and detection efficiency of TEM. To improve the noise performance of the TEM receiver, we have designed a low-noise amplifier using the current source long-tail differential structure and JFET IF3602 through analyzing the power spectrum characteristics of the TEM forward response. By the designed circuit structure, the JFET operating point is easy to set up. The adverse effect on the JFET differential structure by JFET performance differences is also weakened. After establishing the noise model and optimizing the parameters, the designed low-noise differential amplifier has a noise level of , which increases the number of effective data 2.6 times compared with the LT1028 amplifier.