Angela Santilio

Dr. Angela Santilio

Department of Environment and Health, Italian National Institute of Health, Rome, 00161, Italy

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2019 in Journal of Environmental Science and Health, Part B
Verified
Journal Article
Closed access
Angela SantilioAngela Santilio
Angela Santilio
CPChiara Pompili
Chiara Pompili
AGArianna Giambenedetti
Arianna Giambenedetti
A fast and easy method was developed for the determination of glyphosate in maize and rice by using liquid chromatography triple quadrupole mass spectrometry with a Dionex Ion Pack column and phosphate buffer mobile phase. Samples were extracted with an acidified methanol solution. An isotope-labeled internal standard was added to the sample before extraction to ensure accurate tracking and quantification. The method’s performance was evaluated through a series of assessments to determine the accuracy, precision, linearity, matrix effect, limit of detection (LOD), and limit of quantification (LOQ). The mean recoveries for both matrices were within 70–105% at three fortification levels, including the LOQ. The precision for replicates was <20% (RSD%) for both matrices. Good linearity (R2=0.9982) was obtained over the concentration range of 0.01–1.5 mg kg−1. The LOD was determined to be 0.002 mg kg−1 for rice and 0.004 mg kg−1 for maize. The LOQ was 0.01 mg kg−1 for both maize and rice. Due to its versatility, the proposed method could be considered useful for the determination of glyphosate in cereals in routine analysis.

1 January 1990 in The Analyst
Verified
Journal Article
Closed access
PDF file
AMAlfonso Di Muccio
Alfonso Di Muccio
AAAntonella Ausili
Antonella Ausili
LVLuciano Vergori
Luciano Vergori
ICIvano Camoni
Ivano Camoni
RDRoberto Dommarco
Roberto Dommarco
FVFabio Vergori
Fabio Vergori
A multi-cartridge system has been developed which, in a single step, performs the extraction and clean-up of organophosphate (OP) pesticide residues from oils and fatty extracts. A solution in hexane containing up to 1.8 g of lipidic material is loaded on to an Extrelut-3 column to which a silica-gel cartridge and a C18 silica cartridge have been connected in series. The OP pesticide residues are eluted with 15 ml of acetonitrile. Carry-over of fatty material is in the range 2–5 mg per 1.8 g of different oils, which makes the final solution amenable to capillary gas chromatography. Recoveries of 23 OP pesticides were in the range 82–111%. The whole procedure takes ca. 20 min and compares favourably with current procedures.

4 July 2011 in Journal of Environmental Science and Health, Part B
Verified
Journal Article
Closed access
Angela SantilioAngela Santilio
Angela Santilio
PSPatrizia Stefanelli
Patrizia Stefanelli
SGSilvana Girolimetti
Silvana Girolimetti
RDRoberto Dommarco
Roberto Dommarco
A simple and rapid method has been studied for the determination of acidic herbicides (2,4-D, Dichlorprop, Dichlorprop-p, Fluazifop, Fluroxypyr, MCPA, Mecoprop and Mecoprop-p) on cereals (rye). The method involves an alkaline hydrolysis with sodium hydroxide in order to release covalently bound compounds, prior to QuEChERS extraction, followed by neutralization and analysis via liquid chromatography-double mass spectrometry LC/MS/MS. The performance of the method either with or without alkaline hydrolysis was studied in terms of recovery rates and limit of quantification (LOQ). In either case, recoveries were determined at four spiking levels (0.02 mg/kg, 0.05 mg/kg, 0.1 mg/kg and 0.5 mg/kg) with 5 replicates for each level. Mean recoveries ranged from 90 to 120 %, whereas relative standard deviations (RSD %) proved to be less than 20 %. Quantitative analysis was carried out by the internal standard (Nicarbazin) and the LC/MS/MS analysis was performed in electrospray ionisation (ESI) negative mode using a Zorbax XCB Eclipse column. The developed method was applied to the analysis of several cereals commercially available like as rye flour, oat meal, oat flakes and dehusked oat. Residue levels were found below the limit of quantification (LOQ) of the method. The method has been tested in EU Proficiency Tests for cereals with good results.

26 March 2014 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
Angela SantilioAngela Santilio
Angela Santilio
SGS. Girolimetti
S. Girolimetti
DBD. Attard Barbini
D. Attard Barbini
Due to strict regulatory requirements for pesticide residue analysis, only the results of residue analysis with acceptable quality should be reported. As a consequence proper validation of the measurement method is required. In this context, accuracy, precision, specificity, limit of determination (LOQ), matrix effect, linearity, uncertainty calculation and ruggedness become increasingly important. This paper reports a description of the validation parameters of a fast method for the determination of five phenoxy acid herbicides (2,4-D, MCPA, MCPP, haloxyfop and fluazifop) in food crops. The recoveries were performed in the concentration range from 0.05 to 0.5 mg kg–1 for apples, pears, carrots and celeriac with five replicates at each level. The mean recoveries ranged from 70% to 95% for all crops. The precision of the method expressed as a relative standard deviation (RSD%) was found to be in the range 3–14%. For all herbicides, the linearity response of the detector was tested by correlation coefficients (r2 > 0.99) in the concentration range from 0.05 to 0.5 mg kg–1. The LOQ was determined as the lowest spiked level meeting the requirement of accuracy (70–120%) and precision (RSD% < 20% according to European Union guidelines. The uncertainty and robustness were calculated. On the basis of the results, the method can be considered fast, simple and robust and is suitable to be applied to the analysis of studied herbicides in routine testing laboratories.

13 July 2009 in Journal of Environmental Science and Health, Part B
Verified
Journal Article
Closed access
Angela SantilioAngela Santilio
Angela Santilio
PSPatrizia Stefanelli
Patrizia Stefanelli
RDRoberto Dommarco
Roberto Dommarco
A fast, simple and inexpensive method has been developed for the analysis of phenoxy acid herbicides: 2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(4-chloro-o-tolyloxy)propionic acid (MCPP), 2-(4-aryloxyphenoxy)propionic acid (Fluazifop) and 2-(4-aryloxyphenoxy)propionic acid (Haloxyfop) in carrots and apples by liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS). The compounds were analyzed by QuEChERS (quick, easy, cheap, effective, rugged, safe) methodology without cleanup. The recoveries were performed at two spiked levels (0.05 and 0.5 mg/kg) for both matrices with six replicates for each level. The mean recoveries ranged from 70-92% for both apples and carrots. The precision of the method expressed as relative standard deviation (RSD%) was found to be in the range 3-15%. For all compounds, good linearity (r(2) > 0.99) was obtained over the range of concentration from 0.05 micro g/mL to 0.5 micro g/mL, corresponding to the pesticide concentrations of 0.05 mg/kg and 0.5 mg/kg, respectively. The determination limits (LOQs) ranged from 0.01 ng/mL to 1.3 ng/mL in solvent, whereas, the LOQs calculated in matrix ranged from 0.05 ng/g to 21.0 ng/g for apples and from 0.06 ng/g to 10.2 ng/g for carrots. The developed methodology combines the advantages of both QuEChERS and LC/MS/MS producing a very rapid, sensitive and cheap method useful for the routine analytical laboratories.

3 March 2022 in Journal of Environmental Science and Health, Part B
Verified
Journal Article
Closed access
Angela SantilioAngela Santilio
Angela Santilio
SGSilvana Girolimetti
Silvana Girolimetti
VPValentina Picardo
Valentina Picardo
Rapid, sensitive and selective method was studied for the determination of glyphosate in rice and wheat flour using a Raptor Polar column. Samples were extracted with acidified methanol solution. Isotope labeled internal standard was added with the extraction solvent to ensure accurate tracking and quantitation. The glyphosate was analyzed by liquid chromatography tandem mass spectrometry using a Raptor Polar column. Method performance was evaluated through a series of parameters that include accuracy, precision, linearity, limit of detection (LOD), limit of quantitation (LOQ) and matrix effect. Mean recoveries for all matrices were within 96–116% at three fortification levels. Precision for replicates was ≤19% relative standard deviation (RSD%) for wheat and ≤9% RSD% for rice across all fortification levels. Linearity was good for both matrices with a correlation coefficient >0.999 and residual <20% in the concentration range 0.025–1 mg kg−1. LOD was 0.005 mg kg−1for both rice and wheat flour and the LOQ was 0.05 mg kg−1for both matrices. The matrix effect was also studied. A successful method for the analysis of glyphosate in wheat and rice flour assure that the criteria of acceptability of the maximum residue levels (MRLs) are insured.