Ivan Musiiaka

Ivan Musiiaka


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Strength of Materials and Theory of Structures
Verified
Journal Article
Open access
PDF file
OMOleksandr Molodid
Oleksandr Molodid
Oleksandr KovalchukOleksandr Kovalchuk
Oleksandr Kovalchuk
VSVolodymyr Skochko
Volodymyr Skochko
RPRuslana Plokhuta
Ruslana Plokhuta
OMOleksandr Molodid
Oleksandr Molodid
IMIvan Musiiaka
Ivan Musiiaka
Inthe first 100 days of the full-scale armed aggression of Russia's armed forces against Ukraine, more than 1600 rocket strikes were carried out, not including other shelling.In this regard, numerous buildings and structures suffered various damages. Using the developed "Methodology of surveying and registration of its results", surveyors developed a procedure for surveying many buildings and structures in a short period. KNUCA (Kyiv National University of Construction and Architecture) specialists inspected multi-apartment, communal, and administrative buildings in the Borodiankavillageinthe Kyiv region.Based on the results of the surveys, damage to buildings was systematized depending on their causes, namely explosions, and their impact on structures – explosive shock wave, fire, and bullet or shrapnel damage. The direct damage caused by the explosive shock wave included: destruction, cracking, distortion, and declination from the axis of symmetry, damage to window glasses and frames, for brick structures: knocking out (individual bricks or sections of the wall), protrusion (indentation) and displacement of masonry elements, cracks in masonry and spilling of seams between building elements.The direct damage to structures from shrapnel and bullet injuries includes: through holes, splinters, damage to coatings and the roofing layer, jamming of structures, et cetera.The direct damage to structures caused by thermal effectsincludes fire damage, including irreversible thermal elongation of reinforcement and destruction of concrete; damage to the finishing layers; destruction of window and door frames and their filling; the collapse of the roof; destruction of wooden walls and ceilings. KNUCA specialists established that buildings suffer significant damage and destruction when an aerial bomb hits. The most destructive effect is the damage caused by multiple launch rocket systems (MLRS), artillery weapons, and tanks. However, buildings (building structures) suffer minor damage when hit by Armory Personnel Carriers (APVs) and small arms.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
OMOleksandr Molodid
Oleksandr Molodid
RPRuslana Plokhuta
Ruslana Plokhuta
IMIvan Musiiaka
Ivan Musiiaka
IRIvan Reznichenko
Ivan Reznichenko
The most common defect of underground parts of engineering structures is the leakage of water inside. Most often, such leaks can be observed at the joints and joints of concrete and reinforced concrete structures. Typically, such defects are eliminated by sealing the joints using a variety of repair materials. The authors performed experimental studies that aimed at testing the water resistance and frost resistance of pressurized joints of reinforced concrete structures using the latest polymeric materials of the SPT® brand. For this purpose, samples were made, which consisted of two concrete elements in the joint of which the polyurethane material SPT® Resins was injected. Part of the samples was examined for water resistance (simulated hydrostatic pressure), the other part for frost resistance (simulated freezing/thawing by the accelerated method). Additionally, the water resistance of the material under excess pressure and the effect of alternating temperature change on the bond strength of the material with the concrete base were tested. The results of experimental studies have shown that the polymeric material that used in the research has high waterproof and adhesive properties, so it can be used to seal joints between concrete and reinforced concrete elements under hydrostatic water pressure and variable freezing and thawing even without stopping infrastructure.

12 November 2022
Verified
Conference Paper
Closed access
KAKyiv National University of Construction and Architecture
Kyiv National University of Construction and Architecture
OMOleksandr Molodid
Oleksandr Molodid
RPRuslana Plokhuta
Ruslana Plokhuta
IMIvan Musiiaka
Ivan Musiiaka

28 May 2026 in Strength of Materials and Theory of Structures
Verified
Journal Article
Open access
PDF file
OMOleksandr Molodid
Oleksandr Molodid
RPRuslana Plokhuta
Ruslana Plokhuta
IMIvan Musiiaka
Ivan Musiiaka
MOMaksym Omelchenko
Maksym Omelchenko
YNYevheniia Novak
Yevheniia Novak
Given the security situation in Ukraine, some underground structures and premises are used as simple shelters to protect the population from explosions and shrapnel. Certain requirements are imposed on the maintenance of such structures, namely: the structure must be protected from the effects of ground, surface and technical water by means of waterproofing. If the waterproofing is damaged or missing, the structures lose their operational properties and collapse. In addition, high humidity has a negative impact on the people inside. There are three common methods for repairing or installing waterproofing: excavating the structure and applying waterproofing from the outside, installing waterproofing from the inside, or installing external waterproofing using the injection method. To ensure sustainable development with the aim of reducing the impact on the environment and human health, the third method of waterproofing is the most acceptable. Given the wide choice of materials and their properties, it is advisable to study the effectiveness of the technology of waterproofing by injecting material outside the structure (externally). To this end, a series of experimental laboratory studies were carried out, which revealed the influence of soil moisture on the material's ability to increase in volume, spread and adhere to the structure. The waterproofing properties of the material were also tested. Based on the results obtained, practical recommendations were formulated for the use of improved technology for external waterproofing of underground structures. The optimal level of soil moisture for waterproofing was established. Further research directions were outlined for the installation of external horizontal waterproofing of reinforced concrete structures.

29 November 2024 in WAYS TO IMPROVE CONSTRUCTION EFFICIENCY
Verified
Journal Article
Open access
PDF file
OMOleksandr Molodid
Oleksandr Molodid
RPRuslana Plokhuta
Ruslana Plokhuta
IMIvan Musiiaka
Ivan Musiiaka
As a result of military operations, a significant part of construction objects was damaged by off-design impacts. Among the damaged structures, a significant proportion is accounted for ceiling. In our case, majority of ceilings are made of hollow-core reinforced concrete slabs. According to the current regulatory documents, some of these ceilings are subject to restoration. Therefore, the analysis and identification of the most rational and effective technologies for restoring the operational suitability of damaged building structures, in particular, ceilings, is an urgent task today. The article analyzes the known classical and new technologies for repairing and strengthening reinforced concrete slabs, including: dismantling damaged slab and following production of the plate in-place; applying cement-based repair mortars; repairing with epoxy materials; strengthening structures with carbon or basalt materials; classical technologies (bringing metal unloading beams from above (below), installing double-cantilever unloading beams, installing tie bars, creating indistinguishability of beams, building up the beams, etc.). The advantages and disadvantages of each of the technologies, both structural and technological, were identified. The analysis shows that the existing methods are aimed either at repairing damage or at strengthening defect-free structures. Therefore, the development of new or improvement of known technologies for the comprehensive restoration of hollow core slabs is an urgent task. However, taking into account the types of damage to hollow-core slabs as a result of off-design impacts, a new or improved technology for their comprehensive restoration is currently needed. At the same time, such a technology should be structurally and technologically reasoned.

1 September 2026 in Transfer of innovative technologies
Verified
Journal Article
Open access
PDF file
OMOleksandr Molodid
Oleksandr Molodid
СБСергій Бендерський
Сергій Бендерський
РПРуслана Плохута
Руслана Плохута
IMIvan Musiiaka
Ivan Musiiaka
Усі стінові конструктивні елементи незалежно від виду матеріалу з часом під дією чинників різного походження зазнають пошкоджень та потребують виконання ремонтно-відновлювальних робіт для продовження їх експлуатаційної придатності. Виконаним аналізом звітів із технічного обстеження встановлено, що близько 20 % від загальної кількості пошкоджених конструкцій складають кам’яні конструкції. Із них близько 60 % конструкції із повнотілої цегли, а решта із порожнистих елементів (порожниста цегла чи керамічні блоки) та блоків ніздрюватого бетону. Аналіз науково-технічної літератури свідчить про відсутність даних щодо ремонту тріщин конструкцій із порожнистих елементів та дослідження характеру заповнення порожнин ремонтними матеріалами. Тому було виконано експериментальні дослідження спрямовані на визначення якості заповнення ін’єкційним розчином тріщин у конструкціях із порожнистої цегли та із керамічних блоків, а також виконано дослідження можливості використання кварцового піску у якості наповнювача тріщини з подальшим її ін’єктуванням полімерними матеріалами. Встановлено, що ін’єктування тріщин конструкцій із порожнистих елементів з використанням цементного ремонтного ін’єкційного матеріалу ефективно та якісно їх заповнює. Однак відомо, що полімерні матеріали мають хорошу проникну здатність та забезпечують кращу адгезію. Але їх застосування для заповнення порожнистих елементів є недоцільним у зв’язку із значними об’ємами. Тому було досліджено можливість застосування кварцового піску у якості наповнення тріщин з подальшим ін’єктуванням полімерних матеріалів. Параметри адгезійної міцності зчеплення ремонтного матеріалу (пісок просочений полімерною композицією) з основою свідчить про доцільність проведення подібних подальших експериментальних досліджень і на порожнистих елементах