Yoichi Sato

Dr. Yoichi Sato

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
YSYoichi Sato
Yoichi Sato
NYNorio Yamamoto
Norio Yamamoto
NINaoya Inagaki
Naoya Inagaki
YIYusuke Iesaki
Yusuke Iesaki
TATakamune Asamoto
Takamune Asamoto
STShunsuke Takahara
Shunsuke Takahara
Although the number of patients with osteoporosis is increasing worldwide, diagnosis and treatment are presently inadequate. In this study, we developed a deep learning model to predict bone mineral density (BMD) and T-score from chest X-rays, which are one of the most common, easily accessible, and low-cost medical imaging examination methods. The dataset used in this study contained patients who underwent dual-energy X-ray absorptiometry (DXA) and chest radiography at six hospitals between 2010 and 2021. We trained the deep learning model through ensemble learning of chest X-rays, age, and sex to predict BMD using regression and T-score for multiclass classification. We assessed the following two metrics to evaluate the performance of the deep learning model: (1) correlation between the predicted and true BMDs and (2) consistency in the T-score between the predicted class and true class. The correlation coefficients for BMD prediction were hip = 0.75 and lumbar spine = 0.63. The areas under the curves for the T-score predictions of normal, osteopenia, and osteoporosis diagnoses were 0.89, 0.70, and 0.84, respectively. These results suggest that the proposed deep learning model may be suitable for screening patients with osteoporosis by predicting BMD and T-score from chest X-rays.

3 May 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YSYoichi Sato
Yoichi Sato
YTYasuhiko Takegami
Yasuhiko Takegami
TATakamune Asamoto
Takamune Asamoto
YOYutaro Ono
Yutaro Ono
THTsugeno Hidetoshi
Tsugeno Hidetoshi
SHSeiwa Honda
Seiwa Honda
Background: Less experienced clinicians sometimes make misdiagnosis of hip fractures. We developed computer-aided diagnosis (CAD) system for hip fractures on plain X-rays using a deep learning model trained on a large dataset. In this study, we examined whether the accuracy of the diagnosis of hip fracture of the residents could be improved by using this system. Methods: A deep convolutional neural network approach was used for machine learning. Pytorch 1.3 and Fast.ai 1.0 were applied as frameworks, and an EfficientNet-B4 model (a pre-trained ImageNet model) was used. We handled the 5295 X-rays from the patients with femoral neck fracture or femoral trochanteric fracture from 2009 to 2019. We excluded cases in which the bilateral hips were not included within an image range, and cases of femoral shaft fracture and periprosthetic fracture. Finally, we included 5242 AP pelvic X-rays from 4851 cases. We divided these 5242 images into two images per image, and prepared 5242 images including fracture site and 5242 images without fracture site. Thus, a total of 10,484 images were used for machine learning. The accuracy, sensitivity, specificity, F-value, and area under the curve (AUC) were assessed. Gradient-weighted class activation mapping (Grad-CAM) was used to conceptualize the basis for the diagnosis of the fracture by the deep learning algorithm. Secondly, we conducted a controlled experiment with clinicians. Thirty-one residents;young doctors within 2 years of graduation from medical school who rotate through various specialties, were tested using 300 hip fracture images that were randomly extracted from the dataset. We evaluated the diagnostic accuracy with and without the use of the CAD system for each of the 300 images. Results: The accuracy, sensitivity, specificity, F-value, and AUC were 96.1, 95.2, 96.9%, 0.961, and 0.99, respectively, with the correct diagnostic basis generated by Grad-CAM. In the controlled experiment, the diagnostic accuracy of the residents significantly improved when they used the CAD system. Conclusions: We developed a newly CAD system with a deep learning algorithm from a relatively large dataset from multiple institutions. Our system achieved high diagnostic performance. Our system improved the diagnostic accuracy of residents for hip fractures. Level of evidence: Level III, Foundational evidence, before-after study. Clinical relevance: high

13 March 2024 in Archives of Osteoporosis
Verified
Journal Article
Closed access
PDF file
TATakamune Asamoto
Takamune Asamoto
YTYasuhiko Takegami
Yasuhiko Takegami
YSYoichi Sato
Yoichi Sato
STShunsuke Takahara
Shunsuke Takahara
NYNorio Yamamoto
Norio Yamamoto
SIShiro Imagama
Shiro Imagama

25 September 2020 in Research Square
Verified
Preprint
Open access
PDF file
YSYoichi Sato
Yoichi Sato
YTYasuhiko Takegami
Yasuhiko Takegami
TATakamune Asamoto
Takamune Asamoto
YOYutaro Ono
Yutaro Ono
HTHidetoshi Tsugeno
Hidetoshi Tsugeno
SHSeiwa Honda
Seiwa Honda
BackgroundLess experienced clinicians sometimes make misdiagnosis of hip fractures. We developed computer-aided diagnosis (CAD) system for hip fractures on plain X-rays using a deep learning model trained on a large dataset. In this study, we examined whether the accuracy of the diagnosis of hip fracture of the residents could be improved by using this system.MethodsA deep convolutional neural network approach was used for machine learning. Pytorch 1.3 and Fast.ai 1.0 were applied as frameworks, and an EfficientNet-B4 model (a pre-trained ImageNet model) was used. We handled the 5295 X-rays from the patients with femoral neck fracture or femoral trochanteric fracture from 2009 to 2019. We excluded cases in which the bilateral hips were not included within an image range, and cases of femoral shaft fracture and periprosthetic fracture. Finally, we included 5242 AP pelvic X-rays from 4,851 cases. These images were divided into 5242 images that included the fracture site and 5242 images that did not. Thus, a total of 10484 images were used for machine learning. The accuracy, sensitivity, specificity, F-value, and area under the curve (AUC) were assessed. Gradient-weighted class activation mapping (Grad-CAM) was used to conceptualize the basis for the diagnosis of the fracture by the deep learning algorithm. Secondly, we conducted a controlled experiment with clinicians. Thirty-one residents and four orthopedic surgery fellows were tested using 300 hip fracture images that were randomly extracted from the dataset. We evaluated the diagnostic accuracy with and without the use of the CAD system for each of the 300 images.ResultsThe accuracy, sensitivity, specificity, F-value, and AUC were 96.1%, 95.2%, 96.9%, 0.961, and 0.99, respectively, with the correct diagnostic basis generated by Grad-CAM. In the controlled experiment, the diagnostic accuracy of the residents significantly improved when they used the CAD system.ConclusionsWe developed a newly CAD system with a deep learning algorithm from a relatively large dataset from multiple institutions. Our system achieved high diagnostic performance. Our system improved the diagnostic accuracy of residents for hip fractures.Level of EvidenceLevel Ⅲ, Foundational evidence, before-after study. Clinical relevance: high