Franck Moukanda Mbango

Prof. Dr. Franck Moukanda Mbango

Faculty of Sciences and Techniques, Marien Ngouabi University, Brazzaville, Congo
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2021 in International Journal of RF and Microwave Computer-Aided Engineering
Verified
Journal Article
Closed access
PDF file
PMPierre Moukala Mpele
Pierre Moukala Mpele
FMFranck Moukanda Mbango
Franck Moukanda Mbango
DKDominic B. O. Konditi
Dominic B. O. Konditi
FNFabien Ndagijimana
Fabien Ndagijimana

28 July 2020 in IEEE Access
Verified
Journal Article
Open access
FMFranck Moukanda Mbango
Franck Moukanda Mbango
JMJosue Eric Delfort M'PEmba
Josue Eric Delfort M'PEmba
FNFabien Ndagijimana
Fabien Ndagijimana
BMBernard M'PAssi-Mabiala
Bernard M'PAssi-Mabiala
JMJ. E. D. M’pemba
J. E. D. M’pemba
We have presented an open-terminated transmission-line technique, based on the use of two substantially identical circular coaxial structures with different lengths, to extract the material relative permittivity εr. All data acquisitions obtained from experimental measurements have been done at the entry of the connector-input source interface. The technique is well-utilized despite the test cell discontinuity, and it met the goal of extracting the relative intrinsic parameters with good accuracy. The technique improvement found its advantage in the scan of a large frequency range by introducing a new concept based upon the sum of the lengths of identical fixtures and the backward wave propagation. High order-modes propagation that restricts the frequency range in the transmission configuration is not a limit in this new technique. Otherwise, the measurement methodology, grounded in the principle of the automatic correction coefficient determination, is done to achieve the aim. Easily filling up the test cell with the sample to characterize, we validated the new broadband technique in [1.5 – 15] GHz by using insulators like Aquarium sand, wheat semolina, and raffia (vinifera and laurentiis varieties). From the use of the same fixture, result comparisons have been done with those from the two-line technique.

5 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
FMFranck Moukanda Mbango
Franck Moukanda Mbango
Ghislain Fraidy BouesseGhislain Fraidy Bouesse
Ghislain Fraidy Bouesse
FNFabien Ndagijimana
Fabien Ndagijimana
This paper describes a material complex permittivity extraction technique based on four measurements of two identical coaxial (circular and rectangular) lines, distinguished by their lengths. The paper presents a combination of propagation parameters through mixing the eigenvalue principle and the lines’ characteristic impedance to improve the extraction techniques of intrinsic material parameters. However, the accuracy of some material parameters is insufficient, as the discontinuities at the feedline–ideal line interface are not adequately solved. In these cases, a new formulation of the complex effective permittivity is suggested, associating the propagation constant and the characteristic impedance for a homogeneous structure. Next, uncertain errors that can negatively impact the method are removed from the mathematical expression. Then, a characteristic impedance expression is developed in the second stage to improve the mathematical formulation. Finally, a correction coefficient in tune with reality and a polynomial function to amend the behavior of some of the curves are provided. The approach’s novelty lies in its ability to extract and correct the characteristic impedances despite discontinuity impedances at the ideal line–feedline interface. Several materials are tested with circular and/or rectangular coaxial fixtures to confirm the performance of the suggested method. The test cells are homogeneous, full, and long, at 80 mm and 100 mm (50 mm for the circular one). Determining the propagation constant from the eigenvalue of the wave cascading matrix (WCM) is a fundamental step in this method. Knowing the propagation constant helps to automatically compute a correction coefficient that depends on the fixture and the material being tested. Experimental validation is performed in the frequency range from some MHz to 10 GHz, 13.5 GHz, and 20 GHz, according to the tested material. Both test fixtures are filled with the sample material, with a vacuum considered as a reference parameter. The method’s accuracy is better than 5% on the relative permittivity parameter throughout the frequency range. All the tested samples are compared with the results using the filled two-transmission-line technique (FTTL), using only the eigenvalue determination principle. The trapper cells are coaxially circular and rectangular.

22 April 2022 in Measurement: Sensors
Verified
Journal Article
Open access
JMJosué Éric Delfort M'PEmba
Josué Éric Delfort M'PEmba
GBGhislain Fraidy Bouesse
Ghislain Fraidy Bouesse
FMFranck Moukanda Mbango
Franck Moukanda Mbango
BMBernard M'PAssi-Mabiala
Bernard M'PAssi-Mabiala

1 July 2022 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
TBThierno Amadou Mouctar Balde
Thierno Amadou Mouctar Balde
FMFranklin Manene
Franklin Manene
FMFranck Moukanda Mbango
Franck Moukanda Mbango
A compact dual wideband bandpass filter for automotive radar (AR) and 5G millimeter-wave (mmWave) applications with adjustable bandwidths is presented in this work. The filter is based on microstrip dual-mode edge-coupled stub-loaded resonators (SLR). The novelty of this configuration is that it allows independent control of the bandwidths which is not obvious for many reported SLR-based filters. To achieve an overall size of 1.23λ_g× 2.02λ_g, these resonators are coupled and bent int o U-shape, T-shape, and E-shape. The U-shaped resonator, based on a quarter-wavelength transmission line, is coupled to the T-shaped element which constitutes the main feed line to obtain the dual-band response. Having a symmetrical structure, the design i s studied using the even-odd mode analysis. The layout is made using the Ansys high-frequency structural simulator (HFSS) and fabricated on Rogers RO3010 with a thickness of 1.28 mm, a dielectric constant of 10.2, and a loss tangent of 0.0022. The measured bandwidths are 660 MHz and 880 MHz at central frequencies of 23.92 GHz and 28.38 GHz respectively. The measured insertion losses are less than 3.9 dB and the return losses are greater than 17 dB in both bands. A good agreement is obtained between simulate d and experimental results.

3 May 2019 in International Journal of Scientific Research and Management (IJSRM)
Verified
Journal Article
Open access
PDF file
FMFranck Moukanda Mbango
Franck Moukanda Mbango
FNFabien Ndagijimana
Fabien Ndagijimana
We have proposed a simple technique for extracting high frequency material complex relative permittivity from 0.1 GHz up to beyond 5.1 GHz despite the test fixture’s discontinuities along with the characteristic impedance. The frequency range limitation depends on the test fixture’s sizes. Based on the S-parameter measurements, the overall technique associates the test fixture in which the sample to characterize is inserted and the technique for altering the propagation constant of the considered region. Mathematics concepts, through their formulations, allow extracting material complex relative permittivity. The technique foundation is primarily based on the fixture calibration when there is a filling up of vacuum. A coaxial test cell is used to validate the extraction procedure. That fixture is suitable for measuring material electric parameters used in medical and civil engineering, telecommunications, and oil and gas domains. We have presented results ensuing from measures of spring water and biological materials: human tissue and liquid 900 MHz. Both biological materials are liquids and react as a muscle subjected to an electromagnetic wave. The technique is broadband, making it easy to fill up the test cell with the sample to be tested.