Collapsible soils such as gypseous soil are problematic in geotechnical engineering because their volume changes significantly upon saturation. Foundations constructed on gypseous soil undergo sudden and large settlement if the underlying soil experiences unanticipated moisture. The present study aims to improve the gypseous soil behaviour so that it can be used to support shallow foundations. To understand the mechanisms of stabilisation better, a laboratory study is performed to evaluate how polyurethane foam in different amounts influences the volumetric strain, collapse potential and mechanical behaviour of gypseous soil. Physical models of a footing on treated gypseous soil with polyurethane foam are examined to determine the effective treatment zone. Based on the obtained results, 3% polyurethane foam can be recommended to improve the gypseous soil behaviour; the particular reason is its effectiveness in decreasing the change in volumetric strain and collapse potential. The present study develops a theoretical approach that depends on a non-dimensional parameter to predict the ultimate bearing capacity for a footing on the surface of treated gypseous soil using the existing conventional theories.
1 February 2017 in Engineering and Technology Journal
This paper presents an experimental and numerical study to investigate the load carrying capacity of piled raft foundation embedded within partially saturated sandy soil. The effect of matric suction on the bearing capacity of the foundation system was investigated. The experimental work consists of two models of foundation, circular raft foundation and circular piled raft foundation. The circular raft foundation has dimensions of 10cm in diameter, and 2.5cm thickness, while the piled raft foundation has the same dimensions of the circular raft model but with a single pile of 2.0cm in diameter and 40.0cm in length fixed at the center of the raft. Both models are loaded and tested under both fully saturated condition and unsaturated conditions, which are achieved by, predetermined lowering of water table. The lowering of water table below the soil surface was achieved in to two different depths to get different values of matric suction and the relationship between matric suction and depth of ground water table was measured in suction profile set by using three Tensiometers (IRROMETER). The soil water characteristic curve (SWCC) estimated by applying fitting methods through the software (SoilVision). A validation process then was carried out for the case of circular piled raft foundation with lowering the water table 45cm bellow soil surface in the aid of a sufficient finite element computer program ABAQUS 6.12. An eight-node axisymmetric quadrilateral element CAX8RP and CAX8R were used to simulate the soil continuum and piled raft respectively. The interaction method used to simulate the intersect surfaces of the system (pile-raft-soil) is a surface-to-surface discretization method under the concept of master and slave theory. The behavior of piled raft material is simulated by using a linear elastic model while the behavior of soil is simulated by an elasto-plastic model by the use of the Mohr-Coulomb failure criterion. The results of the experimental work demonstrate that the matric suction has a significant role on the bearing capacity of all tested models. It shows that the ultimate bearing capacity of circular raft foundation under a partially saturated condition is increases by about (7.0-8.0) times than the ultimate bearing capacity of fully saturated condition when lowering the water table 45 cm below the soil surface. While the ultimate bearing of circular piled raft foundation under partially saturated condition increases by about (8.0-9.0) times than the ultimate bearing capacity of fully saturated condition when lowering the water table 45 cm below the soil surface. The results of the ultimate bearing capacity of piled raft foundation that obtained from the experimental model and from the numerical modelling for the same soil condition and same matric suction indicate that a successful validation is achieved for the simulation process.
Three-dimensional analysis for the dynamic response of a piled raft foundation subjected to vertical vibration is presented in this study. The analysis considers several factors affecting the amplitude of displacement for deep foundation such as pile cap embedment, pile cap thickness, relative density of the sand and the boundary effect. A validation for an experimental piled raft model depending on a scale factor of (20) using at (Plaxis 3D) computer program was performed. The sand is simulated using Mohr-Coloumb model while the concrete is simulated as linear elastic material. It has been found that embedding the pile cap in the soil and increasing its thickness lead to decrease the maximum amplitude of displacement. Furthermore, the predictions showed that increasing the distance between the foundation and the boundaries and increasing the relative density of the sand can significantly minimize the dynamic response of the foundation.
Foundations supporting reciprocating engines, radar towers, turbines, large electric motors, and generators, etc. are subject to vibrations caused by unbalanced machine forces as well as the static weight of the machine. If these vibrations are excessive, they may damage the machine or cause it not to function properly. In the case of block foundation, if changes in size and mass of the foundation do not lead to a satisfactory design, a pile foundation may be used. In this study, the dynamic response of piles and pile Groups in dry sand is investigated experimentally. The analysis involves the displacement response under harmonic excitation. In addition, a numerical modeling by using finite element method with a three-dimensional formulation is adopted to simulate the experimental model. The results of the numerical model showed that a good agreement is achieved between the predicted dynamic response and that measured from the experimental model.
One of the most important factors for designing a safe foundation is the amount of bearing soil capacity and allowable settlement according to the type of structure. Therefore, in geotechnical engineering, the aim is to improve foundations' bearing capacity in many ways, some of which are expensive, and the other section is difficult to implement in some sites. Skirted foundations consider as an ideal solution to improve cost-wise soil tolerance by reducing materials and installation time. At present, there are several applications, including offshore platforms, bridges, turbines, oil installations, and high-load facilities. This paper investigates the behavior of carrying capacity of skirted foundations through experimental models on the sand. To examine the effect of various saturation conditions, various ratios of length to width of the footing base at different relative densities and different conditions for saturations dry, saturated, and partially saturated soils are considered. It was found that the magnitude of soil bearing enhances with increasing ratios of length to the width of the base of the footings for all cases. The increase in performance ratio increased linearly to 1.5 in footing depth (D/B) and then decreased according to the test results after this point.