Currently, the ocean energy strategy is rapidly developing, and a high proportionate tidal current energy grid connection presents significant obstacles to the planning and secure and stable operation of an island microgrid. For an island microgrid with high proportion tidal current energy access and demand response resources, this research suggests a multiple time scales rolling coordinative dispatching method. An MPPT control based on Q-Learning algorithm is first developed for real-time maximum power tracking of tidal current energy generation after the island microgrid’s topology has been examined. Following that, a multiple time scales rolling coordinative dispatching’s fundamental architecture and implementation method are provided, with equal time intervals coordinated in a step-by-step recursive way. In the example analysis of an island microgrid, we consider the rigid demand load that does not participate in the demand side response, and the ship load and controllable load that participate in the demand side response. On sea islands, ship loads on the long timeframe achieve traffic and energy interaction, and dispatchable loads on the short timescale participate in supply and demand balancing. This is due to the multiple time scales properties of demand response resources. In addition, a multiple time scales rolling coordinative dispatching model for an island microgrid is developed. It includes day-ahead, intraday, and real-time components. Finally, example analysis is used to confirm the dispatching method’s usefulness and advancement, and we conclude that the tidal current energy consumption rate of the island microgrid is increased by 17.08%.
Tidal power generation technology has advanced quickly in recent years. In this study, the Hilbert-Huang transform (HHT) was used to examine the electrical energy distribution law of tidal power generation according to the time periods of days, months, and years based on observed data for tidal power generation. Our analysis summarized the tidal power generation law as follows: in the span of one day, the motor ran for 14 h before shutting off for 10 h. The frequency was 28 Hz, and the maximum voltage was 259 V. The tidal power generation swung twice a month, reaching its peak in the middle of the month and its trough at the beginning. The tidal power output fluctuated twice a year, reaching its peak in August, September, and October and its trough in February, March, and April. In the investigation of tidal power generation patterns, the HHT transformation’s precision and potency were confirmed.