Jan Zimmermann

Mr. Jan Zimmermann

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
JZJan Zimmermann
Jan Zimmermann
MHMichael Huelke
Michael Huelke
MCMatthias Clermont
Matthias Clermont
Biofidel measuring devices are used to validate safety in collaborative workplaces. In these workplaces, humans work together with robots that are equipped with a Power and Force Limiting function (PFL). In this experimental comparison, differences between devices and possible causes are examined more closely. Safety-related parameters are identified in a literature review. Focusing on mechanical aspects, three biofidel measuring devices are analysed and compared in an experimental test series. To this end, a linear motor and a pendulum are used and the steps for comparing concepts are proposed and applied. Depending on the stiffness settings and the materials used, geometry effects on the force-deformation behaviour are shown. An oscillation occurred in one case. The comparison of the three devices shows average differences of 5% in measured peak force between them. This study helps to achieve uniform and comparable results in practice.

29 January 2024 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
RBRoland Behrens
Roland Behrens
JZJan Zimmermann
Jan Zimmermann
ZWZechang Wang
Zechang Wang
SHSebastian Herbster
Sebastian Herbster
NENorbert Elkmann
Norbert Elkmann
Collaborative robots (cobots) can be employed in close proximity to human workers without safety fences. The operation mode Power and Force Limiting requires that cobots not exceed the biomechanical limits of ISO/TS 15066 to ensure protection against injuries caused by collisions with them. Collision tests must be performed to prove that cobots cannot exceed the biomechanical limits. Such tests are performed with a biofidelic measuring device that measures contact forces and replicates the biomechanics of the human body. Biomechanical response curves serve as a reference for the calibration of such devices. In order to be able to compare measurements and limits correctly and reliably, the limits and response curves for calibration must be obtained from the same data with the same methodology. In this article, we present a new technique for developing biomechanical response curves, which employs a statistical model we used to calculate biomechanical limits for cobots in a previous study. This technique's development process entails normalizing the data over force, resampling them and then fitting the newly obtained samples to a log-normal distribution. The statistical model makes it possible to produce response curves for the same quantile we used for the limits. Our technique adds a confidence region around each response curve to express the sufficiency of the available data. We have produced response curves for 24 different body locations for which we have calculated limits. These curves will enable manufacturers of cobot testing equipment to calibrate their measuring devices precisely.

22 May 2025
Verified
Book Chapter
Closed access
PDF file
JZJan Zimmermann
Jan Zimmermann
MCMatthias Clermont
Matthias Clermont
GNGeorg Nischalke-Fehn
Georg Nischalke-Fehn