Ehsan Heydarian-Forushani

Dr. Ehsan Heydarian-Forushani


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
VSVikash Kumar Saini
Vikash Kumar Saini
RKRajesh Kumar
Rajesh Kumar
AAAmeena S. Al-Sumaiti
Ameena S. Al-Sumaiti
SASujil A.
Sujil A.
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani

30 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MRMohammad Mohammadi Rouzbahani
Mohammad Mohammadi Rouzbahani
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani
SHSaeed Hasanzadeh
Saeed Hasanzadeh
Seifeddine Ben El GhaliSeifeddine Ben El Ghali
Seifeddine Ben El Ghali
High penetration of distributed generation and renewable energy sources in power systems has created control challenges in the network, which requires the coordinated management of these resources. Using virtual power plants (VPPs) on a large scale has solved these challenges to a significant extent. VPPs can be considered systems consisting of distributed generations, energy storage, controllable loads, electric vehicles (EVs), and other types of resources to provide energy and ancillary services. VPPs face various challenges such as energy management, operation, resource uncertainty, participation in electricity markets, etc. This paper discusses an overview of the basic challenges of VPPs, including control and communication issues, electricity markets, its different models, and energy management issues. The main purpose is to investigate the performance of VPP in different markets, energy management of VPP in different operating conditions and strategies, and compare different planning methods for VPP. Note that the application of blockchain to control and improve VPP performance has been investigated, taking into account the different layers of this technology.
1

14 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
WNWafa Nafkha-Tayari
Wafa Nafkha-Tayari
Seifeddine Ben El GhaliSeifeddine Ben El Ghali
Seifeddine Ben El Ghali
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani
Mohamed BenbouzidMohamed Benbouzid
Mohamed Benbouzid
Recently, the integration of distributed generation and energy systems has been associated with new approaches to plant operations. As a result, it is becoming increasingly important to improve management skills related to distributed generation and demand aggregation through different types of virtual power plants (VPPs). It is also important to leverage their ability to participate in electricity markets to maximize operating profits. The present study focuses on VPP concepts, its different potential services, various control methodologies, distinct optimization approaches, and some practical implemented real cases. To this end, a comprehensive review of the most recent scientific literature is conducted. The paper concludes with remained challenges and future trends in the topic.

10 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
AAAlya AlHammadi
Alya AlHammadi
NANasser Jamal Al-Saif
Nasser Jamal Al-Saif
AAAmeena Alsumaiti
Ameena Alsumaiti
MMMousa Marzband
Mousa Marzband
TATareefa Alsumaiti
Tareefa Alsumaiti
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani
The United Arab Emirates is moving towards the use of renewable energy for many reasons, including the country’s high energy consumption, unstable oil prices, and increasing carbon dioxide emissions. The usage of electric vehicles can improve public health and reduce emissions that contribute to climate change. Thus, the usage of renewable energy resources to meet the demands of electric vehicles is the major challenge influencing the development of an optimal smart system that can satisfy energy requirements, enhance sustainability and reduce negative environmental impacts. The objective of this study was to examine different configurations of hybrid renewable energy systems for electric vehicle charging in Abu Dhabi city, UAE. A comprehensive study was conducted to investigate previous electric vehicle charging approaches and formulate the problem accordingly. Subsequently, methods for acquiring data with respect to the energy input and load profiles were determined, and a techno-economic analysis was performed using Hybrid Optimization of Multiple Energy Resources (HOMER) software. The results demonstrated that the optimal electric vehicle charging model comprising solar photovoltaics, wind turbines, batteries and a distribution grid was superior to the other studied configurations from the technical, economic and environmental perspectives. An optimal model could produce excess electricity of 22,006 kWh/year with an energy cost of 0.06743 USD/kWh. Furthermore, the proposed battery–grid–solar photovoltaics–wind turbine system had the highest renewable penetration and thus reduced carbon dioxide emissions by 384 tons/year. The results also indicated that the carbon credits associated with this system could result in savings of 8786.8 USD/year. This study provides new guidelines and identifies the best indicators for electric vehicle charging systems that will positively influence the trend in carbon dioxide emissions and achieve sustainable electricity generation. This study also provides a valid financial assessment for investors looking to encourage the use of renewable energy.

16 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HBHamidreza Besharatifard
Hamidreza Besharatifard
SHSaeed Hasanzadeh
Saeed Hasanzadeh
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
PSPierluigi Siano
Pierluigi Siano
Partial Discharge (PD) is one of the symptoms of an electrical insulation problem, and its permanence can lead to the complete deterioration of the electrical insulation in high-voltage equipment such as power transformers. The acoustic emission (AE) method is a well-known technique used to detect and localize PD activity inside oil-filled transformers. However, the commercially available monitoring systems based on acoustic sensors still have a high cost. This paper analyses the ability of low-cost piezoelectric sensors to identify PDs within oil-filled power transformers. To this end, two types of low-cost piezoelectric sensors were fully investigated using time-domain, frequency-domain, and time-frequency analysis, separately. Thereafter, the effectiveness of these sensors for PD detection and monitoring was studied. A three-phase distribution transformer filled with oil was examined. PDs were produced inside an oil-immersed transformer by applying a high voltage over two copper electrodes, and the AE sensors were coupled to the housing of the transformer. By extracting typical features from the AE signals, the PD signals were differentiated from on-site noise and interference. The AE signals were analyzed using acoustic signal metrics such as peak value, energy criterion, and other statistical parameters. The obtained results indicated that the used low-cost piezoelectric sensors have the capability of PD monitoring within power transformers.

23 May 2022 in IEEE Access
Verified
Journal Article
Open access
HBHamidreza Besharatifard
Hamidreza Besharatifard
SHSaeed Hasanzadeh
Saeed Hasanzadeh
EHEhsan Heydarian-Forushani
Ehsan Heydarian-Forushani
S.M. MuyeenS.M. Muyeen
S.M. Muyeen
This paper addresses the localization of Partial Discharge through a 3D Finite Element Method analysis of acoustic wave propagation inside a 3-phase 35kV transformer with the help of COMSOL Multiphysics software. Due to the complexity inside transformers, acoustic waves generated by PDs cannot simply be detected with typical acoustic sensors, especially when PDs happen inside inner windings. These waves are distorted and attenuated along with their propagation. The type, number, and position of sensors are essential factors in PD localization inside a transformer. A new installation arrangement of fiber-optic acoustic sensors inside the transformers is proposed with this information. This array of acoustic sensors has significant effects on PD localization accuracy and has immunity from on-site noise and interference; more importantly, they can be installed after transformer manufacturing. They are reachable if needed to be repaired or replaced. Several numerical studies have been carried out considering different PD source positions, and the Levenberge-Marquardt algorithm is employed for solving localization equations.