Christoph Moos

Mr. Christoph Moos

Department of Prosthodontics, University Hospital Schleswig-Holstein, Kiel, Schleswig-Holstein, Germany
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
AAAyat Aboelela
Ayat Aboelela
CMChristoph Moos
Christoph Moos
APAdrien Emmanuel Arthur Pelloux
Adrien Emmanuel Arthur Pelloux
MPMarcus Pfeiffer
Marcus Pfeiffer
CAChristian Alter
Christian Alter
CKCornelia Keck
Cornelia Keck
Many orally administrated drugs exhibit poor bioavailability due to their limited solubility. The smartFilm technology is an innovative approach to improve the drug aqueous solubility, where the drug is embedded within the matrix of cellulose-based paper in an amorphous state, hence increasing its solubility. Despite its proven effectiveness, smartFilms, i.e., pieces of paper, exhibit limited flowability and are not easy to swallow, and thus oral administration is not convenient. In addition, there is a lack of knowledge of their mechanical behavior under compression. This study aimed to transform unloaded smartFilms, i.e., paper, into a flowable physical form and investigated its mechanical behavior when compressed. Granules made of paper were prepared via wet granulation and were compressed into tablets. The influence of using different amounts and forms of sucrose, as a binder, on the pharmaceutical properties of the produced granules and tablets was studied and the most suitable composition was identified by using instrumented die experiments. For this, the Poisson’s ratio and Young’s modulus were determined for different compaction force levels and the deformation behavior was estimated with the Heckel mathematical model. All granule batches showed good flowability with angle of repose values between 25–35°. Granule batches with ≤30% dry sucrose content produced tablets that fulfilled the European Pharmacopeia requirements, and the compaction behavior of the granules was found to be comparable to the behavior of classical binders and compression enhancers. Paper can be transferred into granules. These granules can be used as suitable intermediate products for the production of tablets made of paper in large, industrial scale.

30 December 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
CMChristoph Moos
Christoph Moos
Stefan KollingStefan Kolling
Stefan Kolling
BWBernd Wöstmann
Bernd Wöstmann
Maximiliane SchlenzMaximiliane Schlenz
Maximiliane Schlenz
SWSebastian Wille
Sebastian Wille
Accurate simulation of prosthetic materials requires constitutive models that capture pressure sensitivity and tension-compression asymmetry beyond linear elasticity. This study presents a reverse-engineering workflow to calibrate a Drucker-Prager based constitutive model in LS-DYNA using the semi-analytical model for polymers MAT 187L SAMP Light for a resin composite (Brilliant Crios) and a polymer-infiltrated ceramic network (Vita Enamic). Unconfined uniaxial compression, three-point bending, and Brazilian disc tests provide elastic constants and strength measures that serve as inputs and calibration targets. An analytical initialization maps experimentally determined yield stresses to the linear Drucker-Prager yield surface, supplying reliable starting parameters for finite element reverse-engineering optimization. The calibrated model captures the material response in the calibration tests (three-point bending and Brazilian disc) within the pre-peak regime, and an out-of-sample punch-through test confirms the transferability of the parameters without additional tuning. Compared to von Mises characterization approaches, the pressure-dependent characterization was achieved with only one additional test configuration, shifting effort from experiments to numerical computation optimization. Within these limits, the results support pressure-dependent, asymmetric plasticity as a practical basis for predictive finite element analysis of dental restoratives, while highlighting that explicit damage and strain-rate effects should be incorporated in future work to model softening and failure consistently.

3 February 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
JKJulie-Jacqueline Kuhl
Julie-Jacqueline Kuhl
Maximiliane SchlenzMaximiliane Schlenz
Maximiliane Schlenz
BWBernd Wöstmann
Bernd Wöstmann
CGChristin Grill
Christin Grill
RBRalf Brinkmann
Ralf Brinkmann
CMChristoph Moos
Christoph Moos
Objectives: This study aimed to determine whether surface wear, identified through the superimposition of intraoral scans (IOS), can predict subsurface damage progression detected by optical coherence tomography (OCT) during fatigue testing of computer-aided design/computer-aided manufacturing (CAD/CAM) composite crowns. Methods: Monolithic CAD/CAM composite crowns (Brilliant Crios; n=8) were adhesively luted to standardized prepared human teeth and artificially aged by cyclic loading in a mouth-motion simulator (50–500 N, 2 Hz, 37 °C). Under phantom-head condition, IOS (surface wear) and handheld swept-source (SS)-OCT (subsurface damage) were performed before loading and after every 250,000 cycles. OCT crack depth/width were normalized to local thickness and cusp-tip distance; correspondence between IOS- and OCT-derived metrics at each timepoint was assessed with Spearman’s rank correlation coefficient (ρ) to test whether surface wear can predict subsurface damage under the given conditions. Results: All specimens survived without catastrophic failure, and both modalities revealed progressive damage from the earliest observation interval. OCT consistently showed higher defect percentages and larger dispersion (e.g., mean vertical defects (25.47 ± 4.97)% OCT vs. (4.36 ± 0.91)% IOS at T1 and (66.79 ± 19.53)% OCT vs. (7.78 ± 3.19)% IOS at T5). Across all timepoints, no statistically significant associations between IOS and OCT were observed (p = 0.146 to 0.955). Conclusions: Within the limitations of this exploratory, single-material in vitro study, restricted to a CAD/CAM composite (Brilliant Crios), surface-based monitoring alone did not reliably reflect subsurface damage progression. Clinically, this suggests that surface wear assessment may underestimate subsurface fatigue damage. Intraoral OCT may provide complementary, non-invasive information alongside routine IOS for individualized monitoring, but its added value needs to be confirmed in larger studies and other CAD/CAM composite materials and additional restorative material classes.

14 July 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
CMChristoph Moos
Christoph Moos
JKJulie-Jacqueline Kuhl
Julie-Jacqueline Kuhl
BWBernd Wöstmann
Bernd Wöstmann
CGChristin Grill
Christin Grill
RBRalf Brinkmann
Ralf Brinkmann
Maximiliane SchlenzMaximiliane Schlenz
Maximiliane Schlenz
This study extended a previously established intraoral scanning (IOS) and optical coherence tomography (OCT) dual-modality monitoring workflow for computer-aided design/computer-aided manufacturing (CAD/CAM) restorations to three additional crown material classes alongside a resin composite (RECO) reference. Four material classes were investigated (n=8 each): RECO, polymer-infiltrated ceramic network (PICN), lithium disilicate ceramic (LDSC), and zirconia-reinforced lithium silicate ceramic (ZLSC). Monolithic crowns were adhesively luted to standardized human molar abutment teeth and aged by cyclic loading (50500N, 2Hz, 37 2∘C, up to 1250000 cycles) in a mouth-motion simulator. IOS and handheld OCT were performed at baseline and after every 250000 cycles under phantom-head conditions; correspondence was assessed using Spearman’s rank correlation coefficient (exploratory, uncorrected for multiple comparisons). OCT consistently showed higher defect extents than IOS across all material classes and timepoints. While no significant IOS-OCT associations were found for RECO and the PICN, OCT detected full-thickness vertical subsurface damage propagation from the earliest timepoint in LDSC and ZLSC, with IOS-derived surface wear remaining markedly lower. Surface-based monitoring alone did not reliably reflect subsurface damage propagation, a dissociation most pronounced in the vertical dimension and silicate-based materials. Intraoral OCT may provide complementary, non-invasive subsurface information to support individualized recall scheduling and minimally invasive repair decisions.