Steffen Staeck

Mr. Steffen Staeck


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SSSteffen Staeck
Steffen Staeck
AAAnna Andrle
Anna Andrle
PHPhilipp Hönicke
Philipp Hönicke
JBJonas Baumann
Jonas Baumann
DGDaniel Grötzsch
Daniel Grötzsch
BKBirgit Kanngießer
Birgit Kanngießer
Scan-free grazing-emission X-ray fluorescence spectroscopy (GEXRF) is an established technique for the investigation of the elemental depth-profiles of various samples. Recently it has been applied to investigating structured nanosamples in the tender X-ray range. However, lighter elements such as oxygen, nitrogen or carbon cannot be efficiently investigated in this energy range, because of the ineffective excitation. Moreover, common CCD detectors are not able to discriminate between fluorescence lines below 1 keV. Oxygen and nitrogen are important components of insulation and passivation layers, for example, in silicon oxide or silicon nitride. In this work, scan-free GEXRF is applied in proof-of-concept measurements for the investigation of lateral ordered 2D nanostructures in the soft X-ray range. The sample investigated is a Si3N4 lamellar grating, which represents 2D periodic nanostructures as used in the semiconductor industry. The emerging two-dimensional fluorescence patterns are recorded with a CMOS detector. To this end, energy-dispersive spectra are obtained via single-photon event evaluation. In this way, spatial and therefore angular information is obtained, while discrimination between different photon energies is enabled. The results are compared to calculations of the sample model performed by a Maxwell solver based on the finite-elements method. A first measurement is carried out at the UE56-2 PGM-2 beamline at the BESSY II synchrotron radiation facility to demonstrate the feasibility of the method in the soft X-ray range. Furthermore, a laser-produced plasma source (LPP) is utilized to investigate the feasibility of this technique in the laboratory. The results from the BESSY II measurements are in good agreement with the simulations and prove the applicability of scan-free GEXRF in the soft X-ray range for quality control and process engineering of 2D nanostructures. The LPP results illustrate the chances and challenges concerning a transfer of the methodology to the laboratory.

18 December 2024 in Nanoscale
Verified
Journal Article
Open access
PDF file
SSSteffen Staeck
Steffen Staeck
JBJonas Baumann
Jonas Baumann
PHPhilipp Hönicke
Philipp Hönicke
NWNils Alexander Wauschkuhn
Nils Alexander Wauschkuhn
FSFerdinand Spikermann
Ferdinand Spikermann
BKBirgit Kanngießer
Birgit Kanngießer
The ability to characterize periodic nanostructures in the laboratory gains more attention as nanotechnology is widely utilized in a variety of application fields. Scanning-free grazing-emission X-ray fluorescence spectroscopy (GEXRF) is a promising candidate to allow non-destructive, element-sensitive characterization of sample structures down to the nanometer range for process engineering. Adopting a complementary metal-oxide semiconductor (CMOS) detector to work energy-dispersively via single-photon detection, the whole range of emission angles of interest can be recorded at once. In this work, a setup based on a Cr X-ray tube and a CMOS detector is used to investigate two $\mathrm{Ti O_2}$ nanogratings and a $\mathrm{Ti O_2}$ layer sample in the tender X-ray range. The measurement results are compared to simulations of sample models based on known sample parameters. The fluorescence emission is simulated using the finite-element method together with a Maxwell-solver. In addition, a reconstruction of the sample model based on the measurement data is conducted to illustrate the feasibility of laboratory scanning-free GEXRF as a technique to non-destructively characterize periodic nanostructures in the tender X-ray range.

19 October 2026 in Applied Physics Letters
Verified
Journal Article
Open access
SSSteffen Staeck
Steffen Staeck
CYC. Yildirim
C. Yildirim
RRR. Rodriguez-Lamas
R. Rodriguez-Lamas
SMS. Moreau
S. Moreau
TDT. Dufrane
T. Dufrane
HPH. F. Poulsen
H. F. Poulsen
We introduce a crossed pair of multilayer Laue lenses (MLLs) as an objective for dark-field x-ray microscopy (DFXM). At the ID03 beamline at ESRF, two flat Mo/C/Si/C with a physical aperture of 50× 50 μm2 were operated confocally at 19.0 keV. The effective pupil was measured to be approximately 44× 43 μm2, corresponding to an effective numerical aperture of 1.58×10−3 at 19.0 keV. The 10% modulation-transfer-function crossings are 51.5(5) nm and 59.8(4) nm in the two image directions, while the angularly integrated analysis gives 55.6(3) nm—more than three times better than for a compound refractive lens (CRL) reference. The dark-field contrast is consistent with the bright-field response. At a sample-detector distance of 2.5 m, the x-ray magnification is 207. The efficiency of the MLL objective is 26.7%. We also characterize the instrumental reciprocal-space response for the three components of the diffraction vector. In normalized units, its rolling and longitudinal FWHMs are 0.0055(1) and 0.0062(1), respectively, and contain only weak secondary components. Finally, intensity and longitudinal-strain maps of a through-silicon-via structure show substantially improved spatial definition relative to CRL-based DFXM. This work expands the science domain of DFXM significantly, both for bulk and near-surface studies. The principal tradeoffs are a short working distance and broader reciprocal-space acceptance.