Debashis Panda

Dr. Debashis Panda

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
MKManoj Kumar
Manoj Kumar
DPDebashis Panda
Debashis Panda
SBSuraj K. Behera
Suraj K. Behera
RSRanjit K. Sahoo
Ranjit K. Sahoo

19 November 2019 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
MKManoj Kumar
Manoj Kumar
DPDebashis Panda
Debashis Panda
RSRanjit K. Sahoo
Ranjit K. Sahoo
SBSuraj K. Behera
Suraj K. Behera

1 October 2019 in Vacuum
Verified
Journal Article
Closed access
DPDebashis Panda
Debashis Panda
SSSunil K. Sarangi
Sunil K. Sarangi
ASAshok. K. Satapathy
Ashok. K. Satapathy

9 September 2019 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
DPDebashis Panda
Debashis Panda
ASAshok Kumar Satapathy
Ashok Kumar Satapathy
SSSunil Kr Sarangi
Sunil Kr Sarangi
In this investigation, the response surface methodology is implemented to analyze the influences of high and low pressure of the compressor, frequency and waiting time of the rotary valve on the cooling capacity and COP of Gifford-McMahon (GM) cryorefrigerator. A one-dimensional numerical model based on finite volume discretization method (FVM) of the governing equations is employed to calculate the cooling capacity and COP of the Gifford-McMahon cryorefrigerator. Analysis of variance (ANOVA) is performed to visualize the impact of the aforementioned input parameters on both cooling capacity and COP. Finally, the particle swarm optimization (PSO) method is opted to optimize the regression equations so obtained from the response surface analysis, to maximize the cooling capacity and COP of the Gifford-McMahon cryorefrigerator. Results reveal that both COP and cooling capacity are not able to produce maximum performance at a particular combination of those input parameters. At a lower pressure ratio, the COP is maximum, while at a higher pressure ratio the cooling capacity is maximum. Furthermore, at a nominal value of waiting time, the cooling capacity is maximum and a higher value of waiting time the COP is maximum. It is observed that, after optimizing the parameters by PSO, the cooling power increases by 11.3% and COP increases by 6.43%.

25 January 2020 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
DPDebashis Panda
Debashis Panda
MKManoj Kumar
Manoj Kumar
ASAshok K. Satapathy
Ashok K. Satapathy
SSSunil K. Sarangi
Sunil K. Sarangi

2 February 2020 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
DPDebashis Panda
Debashis Panda
ASAshok K. Satapathy
Ashok K. Satapathy
SSSunil K. Sarangi
Sunil K. Sarangi
The thermodynamic process parameters such as cooling capacity and percentage Carnot efficiency of an orifice pulse tube refrigerator are maximized using a novel hybrid statistical simulation approach. With the help of a one-dimensional numerical model, the inside gas flow and thermal processes responsible for the production of cooling effect inside the tube has been solved. Subsequently, the thermodynamic process parameters are calculated as a function of input geometrical parameters of the regenerator, pulse tube and orifice valve. Response surface methodology is thereupon applied to investigate the influences of input factors on outputs. Desirability method is finally adopted to maximize both cooling capacity and percentage Carnot efficiency. A sensitivity investigation has been undertaken to find out the degree of influence of each input on the output. An experimental investigation has been conducted at the optimal set of parameters so as to validate the proposed methodology. The investigation shows that, there exists an almost linear relationship among the geometrical parameters of the pulse tube with output, and a non-linear quadratic relationship among the geometrical parameters of regenerator on outputs. Finally, possible combination of input parameters has been generated by the model at which both the outputs are maximum.