A simplified model that calculates the deflagration pressure–time curves of a hydrogen explosion was proposed. The deflagration parameters (pressure peak, duration, deflagration index, and impulse) of hydrogen–air mixtures with different hydrogen concentrations were experimentally investigated. The results show that the pressure curves calculated by the model are consistent with experimental data pertaining to a methane and hydrogen explosion. By comparison, the pressure peak and deflagration index are found to be influenced by the aspect ratio and surface area of vessels. The impulse and explosion times at fuel-lean hydrogen concentrations are greater than those at fuel-rich concentrations. When the hydrogen concentration is between 34 vol.% and 18 vol.%, the greatest explosion damage effect is formed by both the overpressure and the impulse, which should be considered for hydrogen explosion safety design in industrial production.
A series of methane-vented explosions were experimentally investigated in a 4.5 m3 rectangular chamber at P0 = 100 kPa and T0 = 298 K, and the effects of ignition positions and vent areas on the external flame and temperature characteristics were studied. The results indicate that the vent area and ignition position significantly affect external flame and temperature changes. The external flame is portioned into three stages: an external explosion, a violent flame jet with a blue flame, and a yellow flame venting. The temperature peak first rises and then reduces with increasing distance. Rear ignition produces the largest flame lengths and highest temperature, while front ignition leads to the shortest flame and smallest temperature peak. The maximum flame diameter occurs at central ignition. As vent areas increase, the coupling effect of the pressure wave and the internal flame front weakens and the diameter and peak of the high-temperature peak increase. These results can offer scientific guidance for designing disaster prevention measures and evaluating explosion accidents in buildings.
Increasing the proportion of clean energy within the energy structure is a crucial strategy for achieving energy transformation. Hydrogen and ammonia, as leaders in clean energy technologies, have garnered significant global attention. The combination of hydrogen and ammonia has emerged as a novel form of energy storage, transportation, and conversion; however, the safety aspects of their application process warrant closer attention. Research on hydrogen safety has been conducted extensively, with particular focus on the leakage, diffusion, combustion, and explosion processes. Both theoretical research and engineering applications have advanced significantly. In particular, hydrogen detection technology, primarily based on electrical measurement, has matured considerably, while schlieren imaging-based flow field visualization technology is progressing steadily. In contrast, safety research concerning ammonia remains in its early stages. Research on the leakage and diffusion characteristics of ammonia predominantly focuses on liquid ammonia, with a strong emphasis on engineering applications. Studies on the combustion and explosion characteristics of ammonia primarily address flame parameters and the combustion development laws. Ammonia serves as an efficient hydrogen storage medium. The conversion process involving hydrogen and ammonia will occur simultaneously in both time and space. Current research has not adequately addressed the safety concerns associated with the application process of hydrogen–ammonia mixtures. Future research on the safety of hydrogen–ammonia application processes should focus on the diffusion characteristics and combustion and explosion behaviors, as well as the development of electrical measurement detection technologies and optical flow field visualization techniques for hydrogen–ammonia mixtures.