Aurelio Quesada

Prof. Dr. Aurelio Quesada


Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2011 in Circulation
Verified
Journal Article
Open access
PDF file
JSJagmeet P. Singh
Jagmeet P. Singh
HKHelmut U. Klein
Helmut U. Klein
DHDavid T. Huang
David T. Huang
SRSven Reek
Sven Reek
MKMalte Kuniss
Malte Kuniss
AMArthur J. Moss
Arthur J. Moss
Background—: An important determinant of successful cardiac resynchronization therapy for heart failure is the position of the left ventricular (LV) pacing lead. The aim of this study was to analyze the impact of the LV lead position on outcome in patients randomized to cardiac resynchronization-defibrillation in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) study. Methods and Results—: The location of the LV lead was assessed by means of coronary venograms and chest x-rays recorded at the time of device implantation. The LV lead location was classified along the short axis into an anterior, lateral, or posterior position and along the long axis into a basal, midventricular, or apical region. The primary end point of MADIT-CRT was heart failure (HF) hospitalization or death, whichever came first. The LV lead position was assessed in 799 patients, (55% patients ≥65 years of age, 26% female, 10% LV ejection fraction ≤25%, 55% ischemic cardiomyopathy, and 71% left bundle-branch block) with a follow-up of 29±11 months. The extent of cardiac resynchronization therapy benefit was similar for leads in the anterior, lateral, or posterior position ( P =0.652). The apical lead location compared with leads located in the nonapical position (basal or midventricular region) was associated with a significantly increased risk for heart failure/death (hazard ratio=1.72; 95% confidence interval, 1.09 to 2.71; P =0.019) after adjustment for the clinical covariates. The apical lead position was also associated with an increased risk for death (hazard ratio=2.91; 95% confidence interval, 1.42 to 5.97; P =0.004). Conclusion—: LV leads positioned in the apical region were associated with an unfavorable outcome, suggesting that this lead location should be avoided in cardiac resynchronization therapy. Clinical Trial Registration—: URL: http://clinicaltrials.gov . Unique identifier: NCT00180271.

1 May 2014 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
IGIlan Goldenberg
Ilan Goldenberg
VKValentina Kutyifa
Valentina Kutyifa
HKHelmut U. Klein
Helmut U. Klein
DCDavid S. Cannom
David S. Cannom
MBMary W. Brown
Mary W. Brown
AMArthur J. Moss
Arthur J. Moss
The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone.

28 August 2016 in European Journal of Heart Failure
Verified
Journal Article
Closed access
PDF file
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
ACAntoine Da Costa
Antoine Da Costa
AQAurelio Quesada
Aurelio Quesada
RRRenato Pietro Ricci
Renato Pietro Ricci
SFStefano Favale
Stefano Favale
HBHaran Burri
Haran Burri

19 February 2007 in European Heart Journal
Verified
Journal Article
Open access
PDF file
DVDirk Vollmann
Dirk Vollmann
HNHerbert Nägele
Herbert Nägele
PSPatrick Schauerte
Patrick Schauerte
UWUwe Wiegand
Uwe Wiegand
CBChristian Butter
Christian Butter
BLBarbara Lamp
Barbara Lamp
To evaluate the utility of intrathoracic impedance monitoring for detecting heart failure (HF) deterioration in patients with an implanted cardiac resynchronization/defibrillation device. Patients enrolled in the European InSync Sentry Observational Study were audibly alerted by a device algorithm if a decrease in intrathoracic impedance suggested fluid accumulation. Clinical HF status and device data were assessed at enrolment, during regular follow-up, and if patients presented with an alert or HF deterioration. Data from 373 subjects were analysed. Fifty-three alert events and a total of 53 clinical events (HF deterioration defined by worsening of HF signs and symptoms) were reported during a median of 4.2 months. Adjusted for multiple events per patient, the alert detected clinical HF deterioration with 60% sensitivity (95% CI 46–73) and with a positive predictive value of 60% (95% CI 46–73). Higher NYHA class at baseline was predictive for adequate alert events during follow-up (P < 0.05). In 11 of 20 HF deteriorations without preceding alert, an upstroke of the fluid index occurred without reaching the programmed alert threshold. A device-based algorithm that alerts patients in case of decreasing intrathoracic impedance facilitates the detection of HF deterioration. Future randomized, controlled trials are needed to test whether the tailored use of intrathoracic impedance monitoring can improve the ambulatory management of patients with chronic HF and an implanted device.

21 August 2013 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
ACAntoine Da Costa
Antoine Da Costa
Renato Pietro RicciRenato Pietro Ricci
Renato Pietro Ricci
AQAurelio Quesada
Aurelio Quesada
SFStefano Favale
Stefano Favale
OIOn Behalf Of The MORE-CARE Investigators
On Behalf Of The MORE-CARE Investigators
Background: Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. Objective: The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. Methods: In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. Results: The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25th-75th percentile, 1-4) days vs 29 (25th-75th percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). Conclusions: RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. Trial Registration: Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF).

6 March 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
MGMelanie Grehn
Melanie Grehn
SMStefano Mandija
Stefano Mandija
MMMarcin Miszczyk
Marcin Miszczyk
DKDavid Krug
David Krug
Bartłomiej TomasikBartłomiej Tomasik
Bartłomiej Tomasik
JVJoost J C Verhoeff
Joost J C Verhoeff
The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions’ experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.