Radioembolisation (RE) is a minimally invasive therapy for primary/metastatic liver tumours. Yttrium-90 (90Y) microspheres (MS) are infused through the hepatic artery. Positron emission tomography (PET) allows visualisation of the 90Y-MS distribution in the liver after the RE procedure. All patients are submitted to a pretherapeutic Technetium-99m (99mTc) macroaggregated albumin (MAA) perfusion scintigraphy and single-photon emission computed tomography (SPECT) liver imaging. This work investigates the value of pre-treatment 99mTc-MAA SPECT to predict intrahepatic 90Y-MS treatment dosimetry, using the gamma-index (γ-index) analytical method. Six treatments with MAA and MS administered in the same hepatic artery branches were retrospectively selected. Multimodal images were used for semi-automatic and manual segmentation of liver and tumour volumes. Absorbed dose was calculated on SPECT and PET maps using the Imalytics Research Workstation (Philips). The γ-index calculation and analysis were performed using ‘in-house’ software with multiple distance to agreement (DTA) and dose difference (DD) tolerance criteria. γ-index passing rate values of 80% and > 90% were achieved for respectively conservative 10 mm/10% and less conservative 15 mm/15% (DTA/DD) tolerance criteria. RE treatments performed in similar conditions to planning give γ-index passing rates (several DTA/DD criteria) indicating potential predictive power of dosimetry planning for post-radioembolisation dosimetry outcome.
2 November 2018 in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.
Radioembolization (RE) with 90 Y microspheres has been recognized as an emerging treatment strategy for patients with liver tumors either primary or secondary. New tools for complex patient dosimetry, based on real absorbed dose distribution to the normal liver and tumor are under development by our research group at the Champalimaud Centre for the Unknown (CCU), Champalimaud Foundation (CF). Furthermore, we have been using the gamma-index quantitative approach to evaluate the degree of agreement between reference and target voxel-based dose distributions. In this research work, we quantitatively investigated the correlation between dose distributions calculated based on pre-treatment/reference Technetium-99m Macroaggregated Albumin ( 99m Tc-MAA) Single Photon Emission Computed Tomography (SPECT) and post-treatment/target Yttrium-90 ( 90 Y) Positron Emission Tomography (PET) images, to evaluate the predictive power of 99m Tc-MAA SPECT maps in comparison with post-radioembolization 90 Y PET maps. Voxel-based dose distributions were retrospectively calculated based on a total of 13 treatments from 10 patients submitted to RE with 90 Y glass microspheres at CCU-CF. The dose distributions (reference and target) were co-registered to the same matrix resolution and a region extraction algorithm was applied to the entire data for each treatment so that only the liver was considered as the region of interest (ROI). In addition, each slice was normalized to the pixel with the maximum intensity value and a dose threshold was applied to the background level. The gamma-index test was then applied to all reference and target pairs of slices from each treatment image series ( 99m Tc-MAA SPECT and 90 Y PET), using the dose-difference (DD) and distance-to-agreement (DTA) tolerances. The computation based on 1766 dose maps (slices) included in this work, showed that the mean percentage of voxels passing gamma-index, for each patient, varies from 17% to 48%. Considering all the patients, the median of this variability is 35% and the mean value is 33% with a standard deviation of 10% In conclusion, the application of gamma-index tests to our data, with the tolerances considered (DD = 10% and DTA = 5mm), reveals good correlation between pre-treatment 99m Tc-MAA SPECT dose maps and post-treatment 90 Y PET dose maps in one third of the voxels analyzed. Considering that the deposition of the microspheres (glass and MAA) and the dose maps are heterogeneous, these preliminary results are encouraging and led us to further consider the application of this gamma-index quantitative approach together with dose-volume histograms to investigate the additional predictive power of 99m Tc-MAA SPECT maps in comparison with post-therapy 90 Y PET maps.