Rami Ghannam

Prof. Rami Ghannam

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Nano Select
Verified
Journal Article
Open access
PDF file
YLYuchi Liu
Yuchi Liu
HKHamideh Khanbareh
Hamideh Khanbareh
MHMiah Abdul Halim
Miah Abdul Halim
AFAndrew Feeney
Andrew Feeney
XZXiaosheng Zhang
Xiaosheng Zhang
RGRami Ghannam
Rami Ghannam
Wearable devices can be used for monitoring vital physical and physiological signs remotely, as well as for interacting with computers. Widespread adoption of wearables is somewhat hindered by the duration time they can be used without re‐recharging. To ensure uninterrupted operation, these devices need a constant and battery‐less energy supply. Scavenging energy from the wearable's surroundings is, therefore, an essential step towards achieving genuinely autonomous and self‐powered devices. While energy harvesting technologies may not completely eliminate the battery storage unit, they can ensure a maximum duration of use. Piezoelectric energy harvesting is a promising and efficient technique to generate electricity for powering wearable devices in response to body movements. Consequently, we systematically survey the range of technologies used for scavenging energy from the human body, with a particular focus on the upper‐limb area. According to our review and in comparison to other upper limb locations, highest power densities can be achieved from piezoelectric transducers located on the wrist. For short and fast battery charging needs, we therefore review the range of materials, architectures and devices used to scavenge energy from these upper‐limb areas. We provide comparisons as well as recommendations and possible future directions for harvesting energy using this promising technique.

8 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SKSara Khosravi
Sara Khosravi
SBStuart G. Bailey
Stuart G. Bailey
HPHadi Parvizi
Hadi Parvizi
RGRami Ghannam
Rami Ghannam
Wearable sensors have traditionally been used to measure and monitor vital human signs for well-being and healthcare applications. However, there is a growing interest in using and deploying these technologies to facilitate teaching and learning, particularly in a higher education environment. The aim of this paper is therefore to systematically review the range of wearable devices that have been used for enhancing the teaching and delivery of engineering curricula in higher education. Moreover, we compare the advantages and disadvantages of these devices according to the location in which they are worn on the human body. According to our survey, wearable devices for enhanced learning have mainly been worn on the head (e.g., eyeglasses), wrist (e.g., watches) and chest (e.g., electrocardiogram patch). In fact, among those locations, head-worn devices enable better student engagement with the learning materials, improved student attention as well as higher spatial and visual awareness. We identify the research questions and discuss the research inclusion and exclusion criteria to present the challenges faced by researchers in implementing learning technologies for enhanced engineering education. Furthermore, we provide recommendations on using wearable devices to improve the teaching and learning of engineering courses in higher education.

12 November 2018 in IEEE Sensors Journal
Verified
Journal Article
Open access
XLXiangpeng Liang
Xiangpeng Liang
RGRami Ghannam
Rami Ghannam
Hadi HeidariHadi Heidari
Hadi Heidari
This paper presents an innovative wrist-worn device with machine learning capabilities and a wearable pressure sensor array. The device is used for monitoring different hand gestures by tracking tendon movements around the wrist. Thus, an array of PDMS-encapsulated capacitive pressure sensors is attached to the user to capture wrist movement. The sensors are embedded on a flexible substrate and their readout requires a reliable approach for measuring small changes in capacitance. This challenge was addressed by measuring the capacitance via the switched capacitor method. The values were processed using a programme on LabVIEW to visually reconstruct the gestures on a computer. Additionally, to overcome limitations of tendon’s uncertainty when the wristband is re-worn, or the user is changed, a calibration step based on the Support Vector Machine (SVM) learning technique is implemented. Sequential Minimal Optimization (SMO) algorithm is also applied in the system to generate SVM classifiers efficiently in real-time. The working principle and the performance of the SVM algorithms demonstrate through experiments. Three discriminated gestures have been clearly separated by SVM hyperplane and correctly classified with high accuracy (>90%) during real-time gesture recognition.

4 November 2020 in IEEE Access
Verified
Journal Article
Open access
MAMohamed R. R. Abdul-Aziz
Mohamed R. R. Abdul-Aziz
AHA. Hassan
A. Hassan
AAAhmed A. R. Abdel-Aty
Ahmed A. R. Abdel-Aty
MSMohamed R. Saber
Mohamed R. Saber
RGRami Ghannam
Rami Ghannam
AKAhmed S. G Khalil
Ahmed S. G Khalil
To ensure maximum comfort for the wearer, electronic components that include energy harvesters need to be mechanically conformable. In this context, we demonstrate a versatile, cost-effective and efficient method for fabricating graphene supercapacitor electrodes using Laser Induced Graphene (LIG). A CO2 laser beam instantly transforms the irradiated polyethersulfone polymer (PES) into a highly porous carbon structure. The LIG method was used to deposit graphene layers on graphite sheets to produce the supercapacitor electrodes. Graphene formation and morphology were examined and confirmed using several techniques including Scanning Electron Microscopy (SEM), Energy Dispersive X-ray (EDX) spectroscopy, Raman Spectroscopy and Fourier transform infrared spectroscopy (FTIR). Moreover, the electrochemical characterization was performed in different electrolytes (NaOH and KOH). At 5 mV s-1, the LIG electrode achieved 165 mF cm-2 and 250 mF cm-2 in NaOH and KOH electrolytes, respectively. Consequently, we show that a wearable symmetric supercapacitor device with LIG electrodes achieved 98.5 mF cm-2 at 5 mV s-1 in KOH electrolyte. The device demonstrated an energy density of 11.3 μWh.cm-2 with power density of 0.33 mWcm-2 at 0.5 mA cm-2. The retention of capacitance was 75% after 2000 cycles, with outstanding performance for the comparable graphene-based electrodes. These results further validate the use of LIG for developing flexible energy harvesters for wearable applications.

29 September 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
ATAsfand Tanwear
Asfand Tanwear
XLXiangpeng Liang
Xiangpeng Liang
YLYuchi Liu
Yuchi Liu
AVAleksandra Vuickovic
Aleksandra Vuickovic
RGRami Ghannam
Rami Ghannam
Hadi HeidariHadi Heidari
Hadi Heidari
The tracking of eye gesture movements using wearable technologies can undoubtedly improve quality of life for people with mobility and physical impairments by using spintronic sensors based on the tunnel magnetoresistance (TMR) effect in a human-machine interface. Our design involves integrating three TMR sensors on an eyeglass frame for detecting relative movement between the sensor and tiny magnets embedded in an in-house fabricated contact lens. Using TMR sensors with the sensitivity of 11mV/V/Oe and ten <1 mm3 embedded magnets within a lens, an eye gesture system was implemented with a sampling frequency of up to 28 Hz. Three discrete eye movements were successfully classified when a participant looked up, right or left using a threshold-based classifier. Moreover, our proof-of-concept real-time interaction system was tested on 13 participants, who played a simplified Tetris game using their eye movements. Our results show that all participants were successful in completing the game with an average accuracy of 90.8%.

18 September 2024 in Virtual Worlds
Verified
Journal Article
Open access
PDF file
XLXi Li
Xi Li
DEDalia Waleed Elnagar
Dalia Waleed Elnagar
GSGe Song
Ge Song
RGRami Ghannam
Rami Ghannam
This review critically examines the integration of Virtual Reality (VR) and Augmented Reality (AR) in medical training across Low- and Middle-Income Countries (LMICs), offering a novel perspective by combining quantitative analysis with qualitative insights from medical students in Egypt and Ghana. Through a systematic review process, 17 peer-reviewed studies published between 2010 and 2023 were analysed. Altogether, these studies involved a total of 887 participants. The analysis reveals a growing interest in VR and AR applications for medical training in LMICs with a peak in published articles in 2023, indicating an expanding research landscape. A unique contribution of this review is the integration of feedback from 35 medical students assessed through questionnaires, which demonstrates the perceived effectiveness of immersive technologies over traditional 2D illustrations in understanding complex medical concepts. Key findings highlight that VR and AR technologies in medical training within LMICs predominantly focus on surgical skills. The majority of studies focus on enhancing surgical training, particularly general surgery. This emphasis reflects the technology’s strong alignment with the needs of LMICs, where surgical skills training is often a priority. Despite the promising applications and expanding interest in VR and AR, significant challenges such as accessibility and device limitations remain, demonstrating the need for ongoing research and integration with traditional methods to fully leverage these technologies for effective medical education. Therefore, this review provides a comprehensive analysis of existing VR and AR applications, their evaluation methodologies, and student perspectives to address educational challenges and enhance healthcare outcomes in LMICs.