Dunzhu Li

Dr. Dunzhu Li

AMBER Research Centre and Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, D02 PN40 Dublin, Ireland
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YSYifan Sun
Yifan Sun
Dunzhu LiDunzhu Li
Dunzhu Li
Yunhong ShiYunhong Shi
Yunhong Shi
ZWZeena Wang
Zeena Wang
SOSaviour Ifeanyichukwu Okeke
Saviour Ifeanyichukwu Okeke
Liwen XiaoLiwen Xiao
Liwen Xiao
The development of sensors for water quality monitoring is crucial to protect water quality, aquatic biota and human health. Traditional sensor manufacturing methods have significant drawbacks, such as low fabrication freedom, limited material choice and expensive manufacturing cost. As a possible alternative method, 3D printing technologies are increasingly popular in sensor development due to their high versatility, fast fabrication/modification, powerful processing of different materials and ease of incorporation with other sensor systems. Surprisingly, a systematic review examining the application of 3D printing technology in water monitoring sensors has not yet been conducted. Here, we summarized the development history, market share and advantages/disadvantages of typical 3D printing techniques. Specifically focused on the 3D-printed sensor for water quality monitoring, we then reviewed the applications of 3D printing in the development of sensors’ supporting platform, cell, sensing electrode as well as all-3D-printed sensors. The fabrication materials and processing, and the sensor’s performances regarding detected parameters, response time and detection limit/sensitivity, were also compared and analyzed. Finally, the current drawbacks of 3D-printed water sensors and potential directions for future study were discussed. This review will substantially promote the understanding of 3D printing technology used in water sensor development and benefit the protection of water resources.

6 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZeena Wang
Zeena Wang
Dunzhu LiDunzhu Li
Dunzhu Li
Yunhong ShiYunhong Shi
Yunhong Shi
YSYifan Sun
Yifan Sun
SOSaviour Ifeanyichukwu Okeke
Saviour Ifeanyichukwu Okeke
Liwen XiaoLiwen Xiao
Liwen Xiao
Hydrogel materials have been used extensively in microbial electrochemical technology (MET) and sensor development due to their high biocompatibility and low toxicity. With an increasing demand for sensors across different sectors, it is crucial to understand the current state within the sectors of hydrogel METs and sensors. Surprisingly, a systematic review examining the application of hydrogel-based METs to sensor technologies has not yet been conducted. This review aimed to identify the current research progress surrounding the incorporation of hydrogels within METs and sensors development, with a specific focus on microbial fuel cells (MFCs) and microbial electrolysis cells (MECs). The manufacturing process/cost, operational performance, analysis accuracy and stability of typical hydrogel materials in METs and sensors were summarised and analysed. The current challenges facing the technology as well as potential direction for future research were also discussed. This review will substantially promote the understanding of hydrogel materials used in METs and benefit the development of electrochemical biosensors using hydrogel-based METs.

19 January 2024 in Journal of Hazardous Materials
Verified
Journal Article
Open access
YSYunhong Shi
Yunhong Shi
Dunzhu LiDunzhu Li
Dunzhu Li
CHChristopher Hill
Christopher Hill
LYLuming Yang
Luming Yang
ESEmmet D. Sheerin
Emmet D. Sheerin
Liwen XiaoLiwen Xiao
Liwen Xiao
Synthetic polymers are widely used in medical devices and implants where biocompatibility and mechanical strength are key enablers of emerging technologies. One concern that has not been widely studied is the potential of their microplastics (MPs) release. Here we studied the levels of MP debris released following 8-week in vitro tests on three typical polyglycolic acid (PGA) based absorbable sutures (PGA 100, PGA 90 and PGA 75) and two nonabsorbable sutures (polypropylene-PP and polyamide-PA) in simulated body fluid. The MP release levels ranked from PGA 100 > > PGA 90 > PGA 75 > > PP ∼ PA. A typical PGA 100 suture released 0.63 ± 0.087 million micro (MPs > 1 µm) and 1.96 ± 0.04 million nano (NPs, 200-1000 nm) plastic particles per centimeter. In contrast, no MPs were released from the nonabsorbable sutures under the same conditions. PGA that was co-blended with 10-25% L-lactide or epsilon-caprolactone resulted in a two orders of magnitude lower level of MP release. These results underscore the need to assess the release of nano- and microplastics from medical polymers while applied in the human body and to evaluate possible risks to human health.

17 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Dunzhu LiDunzhu Li
Dunzhu Li
Yunhong ShiYunhong Shi
Yunhong Shi
YSYifan Sun
Yifan Sun
ZWZeena Wang
Zeena Wang
DKDaniel K. Kehoe
Daniel K. Kehoe
Liwen XiaoLiwen Xiao
Liwen Xiao
The development of a reusable and low-cost urine glucose sensor can benefit the screening and control of diabetes mellitus. This study focused on the feasibility of employing microbial fuel cells (MFC) as a selective glucose sensor for continuous monitoring of glucose levels in human urine. Using MFC technology, a novel cylinder sensor (CS) was developed. It had a quick response time (100 s), a large detection range (0.3–5 mM), and excellent accuracy. More importantly, the CS could last for up to 5 months. The selectivity of the CS was validated by both synthetic and actual diabetes-negative urine samples. It was found that the CS’s selectivity could be significantly enhanced by adjusting the concentration of the culture’s organic matter. The CS results were comparable to those of a commercial glucose meter (recovery ranged from 93.6% to 127.9%) when the diabetes-positive urine samples were tested. Due to the multiple advantages of high stability, low cost, and high sensitivity over urine test strips, the CS provides a novel and reliable approach for continuous monitoring of urine glucose, which will benefit diabetes assessment and control.

29 August 2025 in Bioresource Technology
Verified
Journal Article
Closed access
YSYifan Sun
Yifan Sun
ZWZeena Wang
Zeena Wang
Dunzhu LiDunzhu Li
Dunzhu Li
YSYunhong Shi
Yunhong Shi
SWShangming Wang
Shangming Wang
Liwen XiaoLiwen Xiao
Liwen Xiao

14 February 2024 in Research Square
Verified
Preprint
Open access
PDF file
JWJing Jing Wang
Jing Jing Wang
Dunzhu LiDunzhu Li
Dunzhu Li
PLPeijing Li
Peijing Li
YSYunhong Shi
Yunhong Shi
ESEmmet Sheerin
Emmet Sheerin
JBJohn Boland
John Boland
Microplastic release from semicrystalline plastics threaten the environment and human health. We investigated polypropylene and polyethylene plastics, which together account for 54% of the global market. Mimicking common levels of residual stress found in plastics via cantilever beam experiments, we demonstrated that compressive stress drives nano and microscale segregation of amorphous polymer droplets onto the plastic’s surface. Simulations reveal this stress-driven volumetric flow is consistent with that of a Bingham plastic material, with a temperature-dependent threshold yield stress. Flow is thermally activated and stress dependent, with a reduced energy barrier at higher compressive stresses. Transfer of surface segregated amorphous droplets into the surroundings generates microplastics. Studies with water-containing plastic bottles showed that the highly compressed neck and mouth regions were predominantly responsible for the release of microplastics.