One of the most useful and simplified approaches in assessing building energy estimates is the degree days method. The heating and cooling requirements can be easily compared for different locations as well as system trends. In this paper, the cooling degree day values for the capitals of the Gulf Cooperation Council (GCC) are presented. Degree day values at different base temperatures are also produced for these locations. These values are useful for engineers and policy makers for evaluating energy demands and their cost for these countries. A typical two-story residential building is considered here and its yearly cooling load is evaluated. The total cooling energy is compared based on the energy cost of the respective GCC countries. The results presented in this investigation illustrated that the cooling load, based on the cooling degree days (CDDs) at a 23 °C base temperature, agrees well with the detailed hourly cooling load simulated by eQuest software. Additionally, the highest CDDs value of 2589 was observed in the city of Doha and the lowest value of 2037 was seen in Riyadh city. The lowest cooling cost of USD 492 corresponds to Muscat, while the highest value of USD 1672 belong to Abu Dubai, partially due to a higher tariff of 0.081 USD/kWh.
The building sector’s energy consumption has significantly increased due to climate change, emphasizing the need to develop sustainable low-energy buildings using experimental and computational tools. As a joint project between Kuwait and Australia, two portable cabins with internal sizes of 2 m × 2 m × 2.80 m, made from 75 mm thick sandwich panels and metal frames, were built in Kuwait to investigate their thermal and power consumption characteristics under various energy-saving techniques and different climates. This is the first attempt to analyze the energy-saving aspects of portable cabins made from sandwich panels for future sustainable cities. Each cabin has an indoor air-quality-sensing device and a novel power-monitoring system to measure their thermal and power consumption characteristics. First, shingles and novel finned metal cool roof (CR) techniques were experimentally investigated. Then, a new multi-zone SketchUp model of the portable cabins was created and simulated in TRNSYS. Next, the energy saving data of the portable cabins were investigated by adding PCM on the walls and the roof using built-in models of bio-phase change materials (Bio-PCMs) in TRNSYS. The annual energy performance index (EPI) as an important sustainability index was explored for determining heating/cooling/total demands of the portable cabins in the desert climate of Kuwait and in various climate regions of Australia. The findings reveal that both shingles and finned metal roofs contributed to higher power consumption. Meanwhile, the use of sustainable Bio-PCMs in Kuwait demonstrates a significant energy-saving potential of 30%, with variations ranging from 25% to over 45% across different climate regions in Australia.
Nowadays, wind energy is one of the most cost-effective and environmentally friendly energies in high demand due to shortages in fossil fuels and the necessity to reduce global carbon footprint. One of the main goals of wind turbine development is to increase the power output of the turbine either by increasing the turbine blade swept area or increasing the velocity of the wind. In this article, a proprietary augmentation system was introduced to increase the power output of vertical axis wind turbines (VAWT) by increasing the free stream velocity to more than two folds. The system comprises two identical airfoiled casings within which the turbine/turbines are seated. The results showed that the velocity slightly increases when decreasing the gap between the casing. It was also found that changing the angle of attack of the housing has more impact on the augmented airspeed. CFD technique was used to assess the velocity and flow of air around the system.
This paper presents a comparative analysis of the thermal performance of three common roofing types - painted, finned, and plain for buildings with customary materials without insulationin- two contrasting climatic contexts: Kuwait City and Vancouver. Experimental data were collected on hourly basis for the surface temperatures for 4 months in winter of Kuwait. Utilizing ASHRAE methods, we simulated the dynamic thermal behaviour of these roofing materials to assess their suitability for mitigating energy demands and enhancing indoor thermal comfort of a building with 127 m2rooftop surface area. Our findings reveal distinct thermal characteristics associated with each roofing type in the respective climates. In Kuwait City’s arid environment, the painted roof emerges as the optimal choice, demonstrating superior performance in reducing thermal loads during hot months while posing challenges related to increased heating demand in cooler seasons with 4.5°C reduction by painted roof. Conversely, in Vancouver’s temperate climate, the painted roof exhibits continuous outward conduction of heat, contributing to elevated heating demands throughout the year despite its effectiveness in maintaining lower temperatures compared to the indoor environment. This study highlights the importance of considering climatic factors and seasonal variations in selecting roofing materials to achieve optimal energy efficiency and indoor comfort. These findings can assist decision-making processes for architects, engineers, and policymakers aiming to enhance building performance and sustainability across diverse climatic regions.
29 March 2026 in Thermal Science and Engineering Progress